ROMEX
Frequently asked questions
Common questions about ROMEX from 3G Electric.
What is ROMEX UF-B underground feeder cable listed to?
ROMEX UF-B cable is listed to UL 493, the standard for underground feeder and branch-circuit cable. Some constructions in the line also carry UL 83 listing for thermoplastic-insulated wire. The cable is rated 600 V and is intended for direct burial, wet locations, and outdoor circuits where a raceway is not used. The gray PVC jacket is sunlight-resistant, moisture-resistant, and flame-retardant. Temperature ratings are 60°C in wet locations and 90°C in dry locations. Buyers should verify the specific SKU's listing and temperature rating against the project specification and the applicable electrical code before installation.
What conductor sizes and configurations are available in the ROMEX UF-B line from 3G Electric?
3G Electric carries ROMEX UF-B in 14 AWG, 12 AWG, 10 AWG, and 8 AWG. Configurations include two insulated conductors (black and white) and three insulated conductors (black, red, and white), each with a bare copper equipment grounding conductor sized to the circuit. Coil lengths in the current catalog include 25 ft and 250 ft. Jacket color is gray. Each SKU is defined by AWG, conductor count, conductor colors, grounding conductor size, and overall length, so the correct cable can be selected directly from the circuit schedule.
Can ROMEX UF-B cable be installed without conduit?
ROMEX UF-B is designed for direct burial and does not require a conduit raceway for that application. The jacket is rated for wet locations and sunlight exposure, so it can also be run outdoors where supported. Installation must follow the applicable electrical code, including minimum burial depth, protection where the cable emerges from the ground, and support intervals. Where physical damage is likely, or where local code requires it, a raceway or other protection may still be necessary. The cable's UL 493 listing covers underground feeder and branch-circuit use; the installer is responsible for confirming that the specific routing and depth meet the code in force at the site.
What is the difference between ROMEX UF-B and standard NM-B cable?
ROMEX UF-B is an underground feeder cable listed to UL 493, with a jacket rated for direct burial, wet locations, and sunlight exposure. Standard NM-B cable is intended for dry, interior locations and is not rated for burial or wet exposure. UF-B uses a solid PVC jacket over the conductor assembly, while NM-B uses a paper-and-plastic sheath within an outer jacket. Both include a bare copper equipment grounding conductor. For outdoor circuits, feeder runs to detached structures, well pumps, and similar applications, UF-B is the appropriate construction. NM-B should not be substituted in wet or buried locations.
How does 3G Electric support ROMEX UF-B orders?
3G Electric lists ROMEX UF-B SKUs with the manufacturer's published specifications, including AWG, conductor count, conductor colors, grounding conductor size, overall length, jacket color, and standards. The catalog covers multiple sizes and coil lengths so buyers can match the cable to the circuit schedule. 3G Electric provides global logistics and quotation on request. For projects requiring documentation, the listed standards and SKU-level specifications are available to support submittals. Buyers should confirm ampacity, voltage drop, and code compliance for their specific installation.
Does 3G Electric supply ROMEX products?
Yes — 3G Electric (S) Pte. Ltd. supplies ROMEX products. We stock the ROMEX catalog and supply genuine factory-original products with full manufacturer warranty and technical support.