SANI-LOCK
Frequently asked questions
Common questions about SANI-LOCK from 3G Electric.
What thermocouple types are compatible with SANI-LOCK extension leads?
SANI-LOCK extension leads are available for Type K and Type T thermocouples. Type K (chromel-alumel) is commonly used in general-purpose industrial applications up to 1260°C, while Type T (copper-constantan) is suited for low-temperature measurements from -200°C to 350°C. The leads are calibrated to match the thermocouple type, ensuring accurate signal transmission. Always verify the thermocouple type of your sensor before selecting a SANI-LOCK extension lead to maintain measurement precision.
What connector types are used on SANI-LOCK extension leads?
SANI-LOCK extension leads feature male mini connectors on both ends. The mini connector is a compact, two-pin design commonly used in thermocouple systems for space-constrained installations. The male configuration allows direct connection to female jacks on thermocouple probes or instruments. This standardized interface ensures compatibility with most industrial temperature controllers and data loggers that accept mini thermocouple connectors.
What cable lengths are available for SANI-LOCK extension leads?
SANI-LOCK extension leads are offered in 3 ft, 6 ft, 10 ft, and 12 ft lengths. The 3 ft and 6 ft options are suitable for short-distance connections between a thermocouple probe and a nearby transmitter or panel. The 10 ft and 12 ft variants provide flexibility for routing cables around equipment or to remote monitoring stations. Choose the length based on the physical distance between the sensor and the measurement device, avoiding excessive slack that could cause tripping hazards or signal degradation.
What is the purpose of the SANI-LOCK ACC-T-202A hole plug?
The SANI-LOCK ACC-T-202A hole plug is a temperature controller accessory designed for use with thermocouples. It is used to seal unused openings in thermocouple wells, probe housings, or instrument panels, preventing contamination, moisture ingress, or heat loss in sanitary environments. The plug has a 1/8-inch overall width, making it suitable for small-diameter holes. It is typically installed during system setup or maintenance to maintain hygienic conditions in food, pharmaceutical, or bioprocessing applications.
Can SANI-LOCK extension leads be used in washdown or high-humidity environments?
SANI-LOCK extension leads are designed for sanitary applications, but specific IP ratings or moisture resistance levels are not provided in the available product specifications. For washdown or high-humidity environments, it is recommended to use additional protective measures such as heat-shrink tubing over connections or routing cables through sealed conduits. The mini connectors are not inherently waterproof, so exposure to direct liquid spray should be avoided unless the system is enclosed in a rated panel or junction box.
What is the difference between SANI-LOCK extension leads and general-purpose thermocouple wire?
SANI-LOCK extension leads are pre-terminated with male mini connectors on both ends, providing a ready-to-use cable assembly for connecting thermocouple probes to instruments. General-purpose thermocouple wire, such as the SANI-LOCK ACC-T1V-10 probe socket, is sold as a spool or cut length without connectors, requiring the user to attach their own terminations. Extension leads offer convenience and consistent connection quality, while general-purpose wire allows custom lengths and connector types. Both are available in Type K and Type T calibrations.