Send a part number, a photo, or a whole BOM — we supply it and stand behind it. EXW Singapore — collect from our office.

3G Electric
Parker Modular Regenerative Desiccant Compressed Air Dryer - Modular Regenerative Desiccant Compressed Air Dryers
ParkerModular Regenerative Desiccant Compressed Air Dryers

Parker Modular Regenerative Desiccant Compressed Air Dryer

The PARKER Desiccant Dryer (SKU K2/16D3-N115M, MPN K2/16D3-N115M) is a modular regenerative desiccant compressed air dryer with a 1/4 in NPT connection. It operates at 9 cfm, with a maximum operating pressure of 232…

SKU 3G-OTH-160137

Also listed as: K216D3N115M · K2 16D3 N115M · K2-16D3-N115M

Brand
Parker
Item
Modular Regenerative Desiccant Compressed Air Dryer
Part Number
K2/16D3-N115M
Category
Modular Regenerative Desiccant Compressed Air Dryers
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. Bank transfer and corporate PO accepted.

Technical Specifications

Parker
Manufacturer Part Number
K2/16D3-N115M
Type
9 cfm, 232 psig Max Op Pressure, 115V, 2 A
Pressure Drop
5 psi

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.
Ask a question

Ask a question

Parker Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The PARKER Desiccant Dryer (SKU K2/16D3-N115M, MPN K2/16D3-N115M) is a modular regenerative desiccant compressed air dryer with a 1/4 in NPT connection. It operates at 9 cfm, with a maximum operating pressure of 232 psig and a pressure drop of 5 psi. The unit requires a 115V, 2 A power supply.

Frequently Asked Questions

What is a Parker desiccant dryer used for?

A Parker desiccant dryer removes moisture from compressed air systems to prevent corrosion, freezing, and contamination in pneumatic tools, instrumentation, and industrial processes. It delivers dry air for critical applications across machining, material handling, and controls.

What are the specifications of the Parker K2/16D3-N115M desiccant dryer?

The Parker K2/16D3-N115M is a modular regenerative desiccant compressed air dryer with a 1/4 in NPT connection, 9 cfm flow, 232 psig max operating pressure, 5 psi pressure drop, and requires 115V, 2 A power supply. It is designed for reliable moisture removal.

Where to buy a Parker desiccant dryer worldwide?

3G Electric supplies and delivers the Parker K2/16D3-N115M desiccant dryer worldwide. We handle full logistics, customs clearance, and delivery to your facility. Contact us for a quote and lead time on this modular regenerative dryer.

How to install a Parker desiccant dryer?

Install the Parker desiccant dryer in a clean, dry location with adequate ventilation. Connect the 1/4 in NPT inlet and outlet to the compressed air line, wire the 115V, 2 A power supply, and follow the manufacturer's manual for purge flow and regeneration cycle setup.

Used in

Common applications for Parker
Hydraulic and pneumatic assembly — Parker 41FL-8 brass 45-degree flare nut for 1/2 in OD tubing in SAE J513 circuits
Compressed-air preparation — Parker Series 06E filter/regulator (06E32B18AC) for 1/2 in NPT lines at up to 125 psig
HVAC and refrigeration service — Parker RC01C-series brass quick couplers with safety stop for refrigerant hoses
Refrigerant recovery equipment — Parker 5400-S5-8 steel female quick coupler for automotive and industrial hose systems
Corrosive fluid-power systems — Parker 1/2 GG-SS 316 stainless NPTF-to-NPTF adapter for 1/2-14 female ports
Industrial valve actuation — Parker ZH and ZB series solenoid coils for hydraulic valve bodies at 24 V DC or 110/220 V AC
Not sure this is the right part? Photo-identify it→

Parker Products

3G Electric supplies Parker modular regenerative desiccant compressed air dryers. We supply genuine products and their technical documentation.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

Cross-referenced by specification & description
This twin-tower regenerative desiccant compressed air dryer removes moisture from compressed air systems using dual desiccant beds, one drying while the other regenerates. It delivers 71 cfm at a maximum operating pressure of 232 psig with a 5 psi pressure drop, and operates on 85 to 265V at 2 A. The 1/2 in NPT connection allows integration into industrial compressed air lines for applications requiring dry air to prevent moisture damage
Parker
This twin-tower regenerative desiccant compressed air dryer removes moisture from compressed air systems using dual desiccant beds, one drying while the other regenerates. It delivers 71 cfm at a maximum operating pressure of 232 psig with a 5 psi pressure drop, and operates on 85 to 265V at 2 A. The 1/2 in NPT connection allows integration into industrial compressed air lines for applications requiring dry air to prevent moisture damage
Twin-tower regenerative desiccant compressed air dryer with 1-1/2 in NPT connection. Delivers 195 cfm at maximum operating pressure of 232 psig with 5 psi pressure drop. Operates on 85-265V at 2 A. Removes moisture from compressed air systems for applications such as pneumatic controls and instrumentation
Parker
Twin-tower regenerative desiccant compressed air dryer with 1-1/2 in NPT connection. Delivers 195 cfm at maximum operating pressure of 232 psig with 5 psi pressure drop. Operates on 85-265V at 2 A. Removes moisture from compressed air systems for applications such as pneumatic controls and instrumentation
Twin-tower regenerative desiccant compressed air dryer with 3/4 in NPT connection. Rated for 97 cfm at 232 psig maximum operating pressure with a 5 psi pressure drop. Operates on 85 to 265V, drawing 2 A. Used in industrial compressed air systems to remove moisture and maintain consistent dew point for pneumatic controls and instrumentation
Parker
Twin-tower regenerative desiccant compressed air dryer with 3/4 in NPT connection. Rated for 97 cfm at 232 psig maximum operating pressure with a 5 psi pressure drop. Operates on 85 to 265V, drawing 2 A. Used in industrial compressed air systems to remove moisture and maintain consistent dew point for pneumatic controls and instrumentation
This twin-tower regenerative desiccant compressed air dryer removes moisture from compressed air systems. Rated for 58 cfm flow, 232 psig maximum operating pressure, and 5 psi pressure drop. Connection size is 1/2 in NPT. Operates on 85 to 265V, drawing 2 A. Suitable for applications requiring dry air such as pneumatic controls and instrumentation
Parker
This twin-tower regenerative desiccant compressed air dryer removes moisture from compressed air systems. Rated for 58 cfm flow, 232 psig maximum operating pressure, and 5 psi pressure drop. Connection size is 1/2 in NPT. Operates on 85 to 265V, drawing 2 A. Suitable for applications requiring dry air such as pneumatic controls and instrumentation
Twin-tower regenerative desiccant compressed air dryer rated for 45 cfm, maximum operating pressure 232 psig, and 5 psi pressure drop. Features 1/2 in NPT connection, operates on 85-265V, 2 A. Used to remove moisture from compressed air systems for pneumatic tools, instrumentation, and industrial processes
Parker
Twin-tower regenerative desiccant compressed air dryer rated for 45 cfm, maximum operating pressure 232 psig, and 5 psi pressure drop. Features 1/2 in NPT connection, operates on 85-265V, 2 A. Used to remove moisture from compressed air systems for pneumatic tools, instrumentation, and industrial processes
Twin-tower regenerative desiccant compressed air dryer with 1 in NPT connection. Delivers 120 cfm at maximum operating pressure of 232 psig with 5 psi pressure drop. Operates on 85 to 265V power. Removes moisture from compressed air systems for pneumatic tools, instrumentation, and processes requiring dry air
Parker
Twin-tower regenerative desiccant compressed air dryer with 1 in NPT connection. Delivers 120 cfm at maximum operating pressure of 232 psig with 5 psi pressure drop. Operates on 85 to 265V power. Removes moisture from compressed air systems for pneumatic tools, instrumentation, and processes requiring dry air

More from Parker

View all Parker parts →
Modular regenerative desiccant compressed air dryer with 1/4 in NPT connections. Rated for 5 cfm at a maximum operating pressure of 232 psig with a 5 psi pressure drop. Operates on 115V, 2 A power supply. Used to remove moisture from compressed air systems for pneumatic tools, instrumentation, and processes
Parker
Modular regenerative desiccant compressed air dryer with 1/4 in NPT connections. Rated for 5 cfm at a maximum operating pressure of 232 psig with a 5 psi pressure drop. Operates on 115V, 2 A power supply. Used to remove moisture from compressed air systems for pneumatic tools, instrumentation, and processes
Modular regenerative desiccant compressed air dryer with 1/4 in NPT connection. Rated for 15 cfm flow, 232 psig maximum operating pressure, and 5 psi pressure drop. Requires 115V, 2 A power supply. Removes moisture from compressed air systems to protect downstream equipment
Parker
Modular regenerative desiccant compressed air dryer with 1/4 in NPT connection. Rated for 15 cfm flow, 232 psig maximum operating pressure, and 5 psi pressure drop. Requires 115V, 2 A power supply. Removes moisture from compressed air systems to protect downstream equipment