We supply parts. EXW Singapore: collect from our office.

LIBERTY PUMPS Simplex Control Panel - Multi-Purpose Pump Control Panels
LIBERTY PUMPSMulti-Purpose Pump Control Panels

LIBERTY PUMPS Simplex Control Panel

The LIBERTY PUMPS Simplex Control Panel is a multi-purpose pump control panel designed for simplex pump operation. It operates at a rated voltage of 208/240/480V AC with a current range of 6 to 10 A, is…

SKU 3G-OTH-102822

Also listed as: SX3431913 · SX34 3 191 3 · SX34-3-191-3

Brand
LIBERTY PUMPS
Item
Simplex Control Panel
Part Number
SX34=3-191-3
Category
Multi-Purpose Pump Control Panels
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. Bank transfer and corporate PO accepted.

Technical Specifications

LIBERTY PUMPS
Manufacturer Part Number
SX34=3-191-3
Type
3, 6 to 10 A, Tether Float, Plastic
AC
208/240/480V
Current
6 to 10 A
Alert Output
Audio
Rated Voltage
208/240/480V AC
Dosing Schedule
Demand Dose
Intrinsic Safety
Not Specified Intrinsically Safe
Includes Reversing
Non-Reversing

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.
Ask a question

Ask a question

LIBERTY PUMPS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The LIBERTY PUMPS Simplex Control Panel is a multi-purpose pump control panel designed for simplex pump operation. It operates at a rated voltage of 208/240/480V AC with a current range of 6 to 10 A, is non-reversing, and features an audio alert output. The panel uses a demand dose dosing schedule and includes a tether float, with a plastic enclosure.

Frequently Asked Questions

What is the LIBERTY PUMPS Simplex Control Panel used for?

The LIBERTY PUMPS Simplex Control Panel controls a single pump in wastewater, effluent, or dewatering applications. It uses a demand dose dosing schedule and a tether float to activate the pump, with an audio alert for alarm conditions. It is suitable for residential or light commercial systems.

What are the specifications of the LIBERTY PUMPS Simplex Control Panel?

The panel operates at 208/240/480V AC, 6 to 10 A, and is non-reversing. It includes a tether float, plastic enclosure, and audio alert output. The dosing schedule is demand dose. It is not specified as intrinsically safe. The manufacturer part number is SX34=3-191-3.

Where to buy the LIBERTY PUMPS Simplex Control Panel worldwide?

3G Electric supplies the LIBERTY PUMPS Simplex Control Panel worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time. We source and deliver this panel to any country.

How to install the LIBERTY PUMPS Simplex Control Panel?

Mount the panel in a dry, accessible location. Connect incoming power at 208/240/480V AC per local codes. Wire the pump to the non-reversing contactor and attach the tether float to the pump. Set the demand dose schedule as needed. Test the audio alert. Always follow the manufacturer's manual.

Used in

Common applications for LIBERTY PUMPS
Wastewater treatment — Liberty Pumps duplex control panel with alternating operation and demand dose for two sewage pumps
Residential sump pits — Liberty Pumps simplex control panel with tether float for automatic dewatering of basement sump
Commercial sewage ejection — Liberty Pumps duplex panel rated 208/240/480V AC for alternating control of two grinder pumps
Industrial process water — Liberty Pumps control panel with visual alert output for monitoring pump status in fluid-handling systems
Outdoor pump stations — Liberty Pumps outdoor-rated plastic enclosure panel with audio alert for remote alarm signaling
Effluent dosing — Liberty Pumps simplex panel with demand dose schedule for timed discharge in septic systems
Not sure this is the right part? Photo-identify it→

LIBERTY PUMPS Products

3G Electric supplies LIBERTY PUMPS multi-purpose pump control panels. We supply genuine products and their technical documentation.

You might also need

Pump Accessories →Valves & Regulation →Motors & Drives →All Products →

Compatible alternatives & equivalents

Cross-referenced by specification & description
Multi-purpose simplex pump control panel for single pump operation in wastewater, effluent, or dewatering systems. Rated 208/240/480V AC, 6 to 10 A, non-reversing, with demand dose dosing schedule. Includes tether float switch for pump start/stop and audio alert output for high-level alarm. Plastic enclosure
LIBERTY PUMPS
Multi-purpose simplex pump control panel for single pump operation in wastewater, effluent, or dewatering systems. Rated 208/240/480V AC, 6 to 10 A, non-reversing, with demand dose dosing schedule. Includes tether float switch for pump start/stop and audio alert output for high-level alarm. Plastic enclosure
Simplex control panel for single pump operation in wastewater, sewage, and dewatering applications. Rated 208/240/480V AC, 4 to 6.3 A, non-reversing, with demand dose scheduling and audio alert output. Enclosure type 3, plastic, with tether float switch
LIBERTY PUMPS
Simplex control panel for single pump operation in wastewater, sewage, and dewatering applications. Rated 208/240/480V AC, 4 to 6.3 A, non-reversing, with demand dose scheduling and audio alert output. Enclosure type 3, plastic, with tether float switch
Multi-purpose pump control panel for simplex pump systems. Operates at 208/240/480V AC with 13 to 18 A current range. Features a tether float switch for demand dose dosing and an audio alert output. Non-reversing, plastic enclosure. Suitable for controlling a single pump in wastewater, effluent, or dewatering applications
LIBERTY PUMPS
Multi-purpose pump control panel for simplex pump systems. Operates at 208/240/480V AC with 13 to 18 A current range. Features a tether float switch for demand dose dosing and an audio alert output. Non-reversing, plastic enclosure. Suitable for controlling a single pump in wastewater, effluent, or dewatering applications

More from LIBERTY PUMPS

View all LIBERTY PUMPS parts →
Multi-purpose pump control panel for duplex pump systems operating at 575V AC and 6 to 10 A. Includes three tether float switches for demand dose level control and provides a visual alert output. Non-reversing type suitable for alternating or lead-lag pump operation in fluid handling applications
LIBERTY PUMPS
Multi-purpose pump control panel for duplex pump systems operating at 575V AC and 6 to 10 A. Includes three tether float switches for demand dose level control and provides a visual alert output. Non-reversing type suitable for alternating or lead-lag pump operation in fluid handling applications
Multi-purpose pump control panel for quadplex configurations, rated 208/230V AC and 6 to 10 A. Non-reversing with audio alert output and demand dose dosing schedule. Enclosure is plastic with NEMA 4X rating. Suitable for managing up to four pumps in wastewater, sewage, or dewatering systems
LIBERTY PUMPS
Multi-purpose pump control panel for quadplex configurations, rated 208/230V AC and 6 to 10 A. Non-reversing with audio alert output and demand dose dosing schedule. Enclosure is plastic with NEMA 4X rating. Suitable for managing up to four pumps in wastewater, sewage, or dewatering systems
This multi-purpose pump control panel is designed for duplex pump systems, managing two pumps with alternating operation and demand dose scheduling. It operates at 575V AC with a current range of 2.5 to 4 A, features a tether float for level sensing, and provides a visual alert output. The non-reversing panel is housed in a plastic enclosure rated for outdoor use
LIBERTY PUMPS
This multi-purpose pump control panel is designed for duplex pump systems, managing two pumps with alternating operation and demand dose scheduling. It operates at 575V AC with a current range of 2.5 to 4 A, features a tether float for level sensing, and provides a visual alert output. The non-reversing panel is housed in a plastic enclosure rated for outdoor use
Multi-purpose pump control panel for simplex (single pump) operation. Rated 120/208/240V AC, 20 to 30 A, with a tether float switch for demand dose activation. Includes audio alert output. Non-reversing. Plastic enclosure. Suitable for wastewater, effluent, or dewatering applications
LIBERTY PUMPS
Multi-purpose pump control panel for simplex (single pump) operation. Rated 120/208/240V AC, 20 to 30 A, with a tether float switch for demand dose activation. Includes audio alert output. Non-reversing. Plastic enclosure. Suitable for wastewater, effluent, or dewatering applications
Multi-purpose pump control panel for duplex pump systems. Operates at 208/240/480V AC, 2.5 to 4 A, non-reversing, with audio alert output and demand dose dosing schedule. Uses tether float for level sensing. Suitable for alternating or lead-lag operation in sump and sewage applications
LIBERTY PUMPS
Multi-purpose pump control panel for duplex pump systems. Operates at 208/240/480V AC, 2.5 to 4 A, non-reversing, with audio alert output and demand dose dosing schedule. Uses tether float for level sensing. Suitable for alternating or lead-lag operation in sump and sewage applications
This simplex control panel is designed for single-pump systems in wastewater, effluent, or dewatering applications. It operates at 120/208/240V AC with a current range of 20 to 30 A, is non-reversing, and uses a tether float switch for demand-dose operation. The panel features a visual alert output and a plastic enclosure
LIBERTY PUMPS
This simplex control panel is designed for single-pump systems in wastewater, effluent, or dewatering applications. It operates at 120/208/240V AC with a current range of 20 to 30 A, is non-reversing, and uses a tether float switch for demand-dose operation. The panel features a visual alert output and a plastic enclosure
This non-reversing duplex control panel manages two pumps in alternating or backup operation. It operates at 208/240/480V AC with a current range of 9 to 14 A, features a tether float switch, and provides a visual alert output. The plastic enclosure is rated NEMA 4X for outdoor or corrosive environments. Suitable for wastewater, sewage, and sump applications requiring demand dose sequencing
LIBERTY PUMPS
This non-reversing duplex control panel manages two pumps in alternating or backup operation. It operates at 208/240/480V AC with a current range of 9 to 14 A, features a tether float switch, and provides a visual alert output. The plastic enclosure is rated NEMA 4X for outdoor or corrosive environments. Suitable for wastewater, sewage, and sump applications requiring demand dose sequencing
Multi-purpose pump control panel for duplex pump systems. Operates at 208/240/480V AC with a current range of 4 to 6.3 A. Features a visual alert output and demand dose dosing schedule. Non-reversing, with tether float and plastic enclosure. Suitable for wastewater, sewage, and industrial sump applications
LIBERTY PUMPS
Multi-purpose pump control panel for duplex pump systems. Operates at 208/240/480V AC with a current range of 4 to 6.3 A. Features a visual alert output and demand dose dosing schedule. Non-reversing, with tether float and plastic enclosure. Suitable for wastewater, sewage, and industrial sump applications