Allanson 444-095 Ferromagnetic Service Replacement Transformer for York Shipley
The Allanson 444-095 is a ferromagnetic service replacement ignition transformer designed for York Shipley oil burners. It operates on a 240V, 60Hz input, delivering a 10,000V secondary output at 23mA, with a large…
SKU 3G-OTH-03205
Also listed as: 444095 · 444 095
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
The Allanson 444-095 is a ferromagnetic service replacement ignition transformer designed for York Shipley oil burners. It operates on a 240V, 60Hz input, delivering a 10,000V secondary output at 23mA, with a large can series design, external junction box, and mid-point grounding. 3G Electric interprets this demand and supplies this genuine OEM replacement across 14 industrial departments, with specialist depth in combustion systems as an authorised distributor.
Frequently Asked Questions
What is the Allanson 444-095 ferromagnetic transformer used for?
The Allanson 444-095 is a service replacement ignition transformer designed for constant-duty commercial and industrial oil burners, specifically York Shipley models. It provides a reliable 10,000 V secondary voltage at 23 mA to ignite fuel oil in heating systems.
What are the specifications of the Allanson 444-095 transformer?
The Allanson 444-095 operates on 240 V input at 60 Hz, with a secondary voltage of 10,000 V RMS and 23 mA short-circuit current. It features a large can size, mid-point grounding, external junction box, and buss bar clip HV terminals. Storage temperature range is -40 to +80 °C.
Where to buy the Allanson 444-095 transformer in Singapore?
3G Electric supplies the Allanson 444-095 ferromagnetic transformer to Singapore. We source and deliver this York Shipley replacement part, handling logistics, customs clearance, and door-to-door delivery for industrial and commercial customers.
How to install the Allanson 444-095 transformer on a York Shipley burner?
Ensure the transformer is mounted securely with the correct air gap of 1/8 to 3/16 inches between electrodes. Connect the 240 V primary supply to the external junction box, and attach the buss bar clips to the HV terminals. Always follow the burner manufacturer's wiring diagram and safety procedures.
Used in
Common applications for AllansonAllanson Products
3G Electric supplies Allanson ignition transformers. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.
