Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Allanson
Size
17.0"x3.6"x2.2"
Lamps
2
Weight
8.0 lb
Lamp mA
2100
Lamp Type
Amalgam
Input Lamps
2
Lamp Length
20" to 48"
Potted Case
PC Board
Input Voltage
48V
Input Wattage
430

Datasheet Content

[{"filename":"UVB248T6-2100-48VDC_07.22.pdf","text":"Specifications Sheet\n UV Ballasts\nUVB248T6-2100-48VDC\n1. Lamp Type\n Amalgam Lamp\n\n Lamp Type / Cata # Manufacture # of Lamps Power (W) Current (A)\n\n TUV-200MSG SURFACIDE LLC 2 200 2.1\n\n TUV200W XPT Philips 2 200 2.1\n\n GPHHA1000T6L Light Sources 2 207 2.1\n\n\n2. Electrical\nBallast type: Program Start (PS) Efficiency: > 90%\nNumber of lamps: 2 Ballast shut down/protection: EOL/OC\nNormal input voltage: 48VDC Ambient temperature: 0 - 40° C\nInput voltage range: 35VDC - 60VDC Case maximum temperature: 75° C\nInput current: 9.0A @ 48VDC Approvals: UL/cUL Recognized, Class\nInput power: 430W @ full load “P”, Indoor, Type 1, CE\nLamp operating frequency: > 30 kHz Sound rating: “A”\n\n\n3. Wiring Diagram 4. Ballast PCB Photo\n Dimensions: 17.0” (L) x 3.6” (W) x 2.2” (H)\n\nDRY CONTACT1\nDRY CONTACT2\n\n\n\n\n For 2 UV Amalgam Lamps\n\n\n5. Features\n1) Diagnostics and indication: The ballast board shall communicate, via the digital output to the main controller\n board, to indicate ballast/lamp status.\n2) Timer -Microcontroller based count down timer to monitor lamp life time, turn off the ballast, and give alarm\n signal. There is individual timer for each ballast/lamp.\n\n\n\n\n 83 Commerce Valley Drive East, Markham ON, L3T 7T3\n www.allanson.com | cservice@allanson.com | T: 1.800.661.7251 | F: 416.752.6717"}]

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Allanson Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

3G-OTH-03024 UV BALLASTS – Program Start

Frequently Asked Questions

What is the Allanson 3G-OTH-03024 UV ballast used for?

The Allanson 3G-OTH-03024 is a program-start UV ballast designed to power two amalgam UV lamps, such as the TUV-200MSG or TUV200W XPT. It is commonly used in water treatment, air purification, and industrial disinfection systems requiring reliable, high-efficiency lamp operation.

What are the specifications of the Allanson 3G-OTH-03024?

The Allanson 3G-OTH-03024 operates at 48 VDC input (range 35–60 VDC), draws 9.0 A, and delivers 430 W. It drives two amalgam lamps at 2100 mA, with dimensions 17.0" x 3.6" x 2.2" and weight 8.0 lb. It features program start, >90% efficiency, and UL/cUL recognition.

Where to buy the Allanson 3G-OTH-03024 in Singapore?

3G Electric supplies the Allanson 3G-OTH-03024 UV ballast to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for pricing and lead time on this program-start ballast for amalgam lamps.

How to install the Allanson 3G-OTH-03024 ballast?

Installation should follow the wiring diagram provided by Allanson. Ensure the 48 VDC input is within the 35–60 VDC range and that the ballast is mounted in a location with ambient temperature 0–40 °C. Connect dry contacts for status monitoring and verify lamp compatibility with the 2100 mA output.

Used in

Common applications for Allanson
Oil burner retrofit maintenance — Allanson CAT 1092 TYPE F transformer replacement in existing Beckett control circuits
Industrial heating-system commissioning — Control transformer installation in multi-stage flame-safeguard burner startup sequences
Plant emergency maintenance — Same-day T92 transformer procurement to restore failed ignition control voltage supply
Burner control-cabinet assembly — Allanson transformer integration in custom control-circuit designs for process-heating applications
Field technician spare-parts kit — Stocking CAT 1092 and T92 variants for mobile maintenance coverage of regional burner installations

Allanson Products

3G Electric supplies Allanson uv ballasts. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Allanson
Allanson
Allanson UVB248T5-425-MV UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB264T6-1400-230V UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB264T5-800-MV UV Ballast – Instant Start

More from Allanson

View all Allanson parts
Allanson
Allanson
Allanson UVB50W-24V UV Ballast – Program Start
Allanson
Allanson
Allanson UVB100WHO-120-240V-LP UV Ballast – Program Start with Dimming
Allanson
Allanson
Allanson UVB264T5-425-MV-P UV Ballast – Instant Start
Allanson
Allanson
Allanson UVB424T6-1000-120-240V-SL UV Ballast – Program Start
Allanson
Allanson
Allanson UVB160WHO-120-277V-SS UV Ballasts – Program Start
Allanson
Allanson
Allanson UVB80W-800-24VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB50W-800-12VDC UV Ballast – Program Start
Allanson
Allanson
Allanson UVB164T6-2100-MV-PDPH UV Ballasts – Program Start