Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

APPLETON ELECTRIC Explosion Proof Pendant: T3C Temp Code, 300 W, Suspended Mount - Bulb-Dependent Jelly Jar Hazardous Location Lights
APPLETON ELECTRICBulb-Dependent Jelly Jar Hazardous Location Lights

APPLETON ELECTRIC Explosion Proof Pendant: T3C Temp Code, 300 W, Suspended Mount

The APPLETON ELECTRIC Explosion Proof Pendant is a bulb-dependent jelly jar hazardous location light with a T3C temperature code. It is rated for Class I, Div 1 and 2, Group A, B, C, D locations, supports up to 300…

SKU 3G-OTH-390954

Brand
APPLETON ELECTRIC
Item
Explosion Proof Pendant: T3C Temp Code, 300 W, Suspended Mount
Category
Bulb-Dependent Jelly Jar Hazardous Location Lights
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

APPLETON ELECTRIC
Manufacturer Part Number
AAU15N
Type
300 W, Suspended Mount
Ht
13 1/2 in
Temperature Code
T3C
Emergency Battery Backup
No
Hazardous Location Rating
Class I, Div 1 and 2, Group A, B, C, D

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

APPLETON ELECTRIC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The APPLETON ELECTRIC Explosion Proof Pendant is a bulb-dependent jelly jar hazardous location light with a T3C temperature code. It is rated for Class I, Div 1 and 2, Group A, B, C, D locations, supports up to 300 W, and features a suspended mount with a 13 1/2 in height (MPN AAU15N). This unit does not include an emergency battery backup.

Frequently Asked Questions

What is the APPLETON ELECTRIC Explosion Proof Pendant used for?

This bulb-dependent jelly jar light is used for hazardous location lighting in Class I, Div 1 and 2, Group A, B, C, D environments, such as oil refineries, chemical plants, and grain handling facilities. It provides safe illumination where flammable gases or vapors may be present.

What are the specifications of the APPLETON ELECTRIC AAU15N?

The AAU15N is a 300 W, suspended mount pendant with a T3C temperature code. It is rated for Class I, Div 1 and 2, Group A, B, C, D hazardous locations. Height is 13 1/2 in. It does not include emergency battery backup. The brand is APPLETON ELECTRIC.

Where to buy the APPLETON ELECTRIC AAU15N worldwide?

3G Electric supplies the APPLETON ELECTRIC AAU15N explosion proof pendant worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.

How to install the APPLETON ELECTRIC explosion proof pendant?

Installation must follow the National Electrical Code (NEC) and local hazardous location regulations. Ensure the pendant is suspended securely and wired by a qualified electrician. Use only bulbs rated for the fixture's 300 W maximum and T3C temperature code to maintain safety compliance.

Used in

Common applications for APPLETON ELECTRIC
Oil and gas refineries — Appleton Electric EDSC21MC2 manual motor switch for controlling pumps in Class I, Division 1 areas
Chemical processing plants — Appleton Electric AEAB13420C hazardous location circuit breaker for motor protection in volatile environments
Pharmaceutical manufacturing — Appleton Electric FSK-1VDR weatherproof cover for duplex receptacles in washdown zones
Wastewater treatment facilities — Appleton Electric UNY250R-A aluminum conduit union for corrosion-resistant connections
Mining operations — Appleton Electric EDSC277-SA tandem 2-gang box for junction points in hazardous dust locations
Food and beverage processing — Appleton Electric JBK-75 iron cover for conduit access fittings in wet or dusty areas

APPLETON ELECTRIC Products

3G Electric supplies APPLETON ELECTRIC bulb-dependent jelly jar hazardous location lights. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
APPLETON Explosion Proof Lighting Fixture: 3,200 lm, T6 Temp Code, 5000K, 300 W, 120/277V AC (MPN ALL2CBU)
APPLETON
APPLETON Explosion Proof Lighting Fixture: 3,200 lm, T6 Temp Code, 5000K, 300 W, 120/277V AC (MPN ALL2CBU)
Hazardous Location Pendant Lens Guard: For Explosion Proof Incandescent Fixture/Haz Location Fixture (MPN AAGU1)
APPLETON ELECTRIC
Hazardous Location Pendant Lens Guard: For Explosion Proof Incandescent Fixture/Haz Location Fixture (MPN AAGU1)
Hazardous Location Pendant Lens Guard: For Haz Location Fixture/Mercmaster HID Fixtures, 11 in Lg (MPN KGU2)
APPLETON ELECTRIC
Hazardous Location Pendant Lens Guard: For Haz Location Fixture/Mercmaster HID Fixtures, 11 in Lg (MPN KGU2)
APPLETON ELECTRIC Mechanical Interlock: 600V AC, Three Phase, 30 A, 4 Pole, 3 Wire (MPN JBR3034-150)
APPLETON ELECTRIC
APPLETON ELECTRIC Mechanical Interlock: 600V AC, Three Phase, 30 A, 4 Pole, 3 Wire (MPN JBR3034-150)
APPLETON ELECTRIC Pin and Sleeve Plug: Gray, 250V DC/600V AC, Three Phase, 30 A, 4 Pole, 4 Wire (MPN ACP3044BC)
APPLETON ELECTRIC
APPLETON ELECTRIC Pin and Sleeve Plug: Gray, 250V DC/600V AC, Three Phase, 30 A, 4 Pole, 4 Wire (MPN ACP3044BC)
APPLETON ELECTRIC Mechanical Interlock: 600V AC, Single Phase, 60 A, 3 Pole, 2 Wire (MPN JBR6023-150)
APPLETON ELECTRIC
APPLETON ELECTRIC Mechanical Interlock: 600V AC, Single Phase, 60 A, 3 Pole, 2 Wire (MPN JBR6023-150)

More from APPLETON ELECTRIC

View all APPLETON ELECTRIC parts
APPLETON ELECTRIC Hazardous Location Lighting Fixtures: T3C Temp Code, 300 W, 120V AC, 13 3/4 in Ht (MPN AP1575)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Lighting Fixtures: T3C Temp Code, 300 W, 120V AC, 13 3/4 in Ht (MPN AP1575)
APPLETON ELECTRIC Hazardous Location Lighting Fixtures: T3C Temp Code, 300 W, 120V AC, Ceiling Mount (MPN AC1575)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Lighting Fixtures: T3C Temp Code, 300 W, 120V AC, Ceiling Mount (MPN AC1575)
APPLETON ELECTRIC Hazardous Location Lighting Fixtures: T3C Temp Code, 300 W, 120V AC, Wall Mount (MPN ALB1575)
APPLETON ELECTRIC
APPLETON ELECTRIC Hazardous Location Lighting Fixtures: T3C Temp Code, 300 W, 120V AC, Wall Mount (MPN ALB1575)