Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

APPLETON ELECTRIC K50 Steel Cover for Conduit Access Fittings - Covers for Conduit Access Fittings
APPLETON ELECTRICCovers for Conduit Access Fittings

APPLETON ELECTRIC K50 Steel Cover for Conduit Access Fittings

This is a steel cover for conduit access fittings from Appleton Electric, designed for use with Appleton Form 35 Unilet Conduit Outlet Bodies. It features a 1/2 in trade size and a screw-in connection type, includes…

SKU 3G-OTH-05389

Brand
APPLETON ELECTRIC
Item
K50 Steel Cover for Conduit Access Fittings
Category
Covers for Conduit Access Fittings
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

APPLETON ELECTRIC
Manufacturer Part Number
K50
Material
Steel
Includes
Screws
Standards
UL 514B
For Use With
Appleton Form 35 Unilet Conduit Outlet Bodies
Connection Type
Screw In
Gasket Included
No
Hazardous Location
Yes

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

APPLETON ELECTRIC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

This is a steel cover for conduit access fittings from Appleton Electric, designed for use with Appleton Form 35 Unilet Conduit Outlet Bodies. It features a 1/2 in trade size and a screw-in connection type, includes screws, and is rated for hazardous locations. The cover complies with UL 514B standards and does not include a gasket.

Frequently Asked Questions

What is the Appleton K50 steel cover for conduit access fittings used for?

The Appleton K50 steel cover seals Appleton Form 35 Unilet Conduit Outlet Bodies in hazardous locations. It provides a screw-in closure for 1/2 in trade size conduit access fittings, ensuring compliance with UL 514B standards. 3G Electric supplies this cover for industrial electrical installations worldwide.

What are the specifications of the Appleton K50 cover?

The Appleton K50 cover is made of steel with a 1/2 in trade size and screw-in connection. It is rated for hazardous locations, includes screws, and complies with UL 514B. No gasket is included. It is designed for use with Appleton Form 35 Unilet Conduit Outlet Bodies.

Where to buy the Appleton K50 cover worldwide?

3G Electric supplies the Appleton K50 cover worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us to source this cover for your hazardous-location conduit access fitting needs.

How to install the Appleton K50 cover on a conduit outlet body?

To install the Appleton K50 cover, align it with the Appleton Form 35 Unilet Conduit Outlet Body opening. Insert the included screws and tighten them securely using a screwdriver. Ensure the cover is fully seated for a proper seal in hazardous locations. Follow local electrical codes and UL 514B guidelines.

Used in

Common applications for APPLETON ELECTRIC
Oil and gas refineries — Appleton Electric EDSC21MC2 manual motor switch for controlling pumps in Class I, Division 1 areas
Chemical processing plants — Appleton Electric AEAB13420C hazardous location circuit breaker for motor protection in volatile environments
Pharmaceutical manufacturing — Appleton Electric FSK-1VDR weatherproof cover for duplex receptacles in washdown zones
Wastewater treatment facilities — Appleton Electric UNY250R-A aluminum conduit union for corrosion-resistant connections
Mining operations — Appleton Electric EDSC277-SA tandem 2-gang box for junction points in hazardous dust locations
Food and beverage processing — Appleton Electric JBK-75 iron cover for conduit access fittings in wet or dusty areas

APPLETON ELECTRIC Products

3G Electric supplies APPLETON ELECTRIC covers for conduit access fittings. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Steel cover for closing and protecting conduit outlet bodies in hazardous locations. Includes screws for secure screw-in connection. Complies with UL 514A. For use with Appleton Form 35 Unilet Conduit Outlet Bodies
APPLETON ELECTRIC
Steel cover for closing and protecting conduit outlet bodies in hazardous locations. Includes screws for secure screw-in connection. Complies with UL 514A. For use with Appleton Form 35 Unilet Conduit Outlet Bodies
Steel cover for conduit access fittings, 1-inch trade size, screw-in connection type. Includes screws. Rated for hazardous locations. Complies with UL 514A. For use with Appleton Form 35 Unilet Conduit Outlet Bodies
APPLETON ELECTRIC
Steel cover for conduit access fittings, 1-inch trade size, screw-in connection type. Includes screws. Rated for hazardous locations. Complies with UL 514A. For use with Appleton Form 35 Unilet Conduit Outlet Bodies
Covers for Conduit Access Fitting: Steel, 3 1/2 in_4 in Trade Size, Screw In (MPN K350&400)
APPLETON ELECTRIC
Covers for Conduit Access Fitting: Steel, 3 1/2 in_4 in Trade Size, Screw In (MPN K350&400)
Steel cover for use with Appleton Form 35 Unilet Conduit Outlet Bodies. Screw-in connection type. Includes screws. Suitable for hazardous locations. Complies with C22.2 No. 18.3
APPLETON ELECTRIC
Steel cover for use with Appleton Form 35 Unilet Conduit Outlet Bodies. Screw-in connection type. Includes screws. Suitable for hazardous locations. Complies with C22.2 No. 18.3
Aluminum cover for use with Appleton Form 85 Unilet Conduit Outlet Bodies. Features a screw-in connection and includes mounting screws. Rated for hazardous locations. Complies with UL 514B standards
APPLETON ELECTRIC
Aluminum cover for use with Appleton Form 85 Unilet Conduit Outlet Bodies. Features a screw-in connection and includes mounting screws. Rated for hazardous locations. Complies with UL 514B standards
Steel cover for closing and protecting conduit access fittings in hazardous locations. Designed for use with Appleton Form 35 Unilet Conduit Outlet Bodies. Includes screws; no gasket. Complies with C22.2 No. 18.3
APPLETON ELECTRIC
Steel cover for closing and protecting conduit access fittings in hazardous locations. Designed for use with Appleton Form 35 Unilet Conduit Outlet Bodies. Includes screws; no gasket. Complies with C22.2 No. 18.3

More from APPLETON ELECTRIC

View all APPLETON ELECTRIC parts
Iron cover for conduit access fittings with chromate-coated finish. Screw-in connection type includes mounting screws. Rated for hazardous locations and complies with C22.2 No. 30 standards. Designed for use with Appleton GRJ Series Outlet Boxes
APPLETON ELECTRIC
Iron cover for conduit access fittings with chromate-coated finish. Screw-in connection type includes mounting screws. Rated for hazardous locations and complies with C22.2 No. 30 standards. Designed for use with Appleton GRJ Series Outlet Boxes
Steel cover for use with Appleton Form 35 Unilet conduit outlet bodies. Screw-in connection for secure closure in hazardous locations. Includes screws; gasket not included. Complies with C22.2 No. 18.3
APPLETON ELECTRIC
Steel cover for use with Appleton Form 35 Unilet conduit outlet bodies. Screw-in connection for secure closure in hazardous locations. Includes screws; gasket not included. Complies with C22.2 No. 18.3
Iron cover for conduit access fittings, chromate coated, for use with Appleton SEH Series Conduit Outlet Boxes. Screw-in connection type, includes screws. UL Listed E2527. Suitable for hazardous locations
APPLETON ELECTRIC
Iron cover for conduit access fittings, chromate coated, for use with Appleton SEH Series Conduit Outlet Boxes. Screw-in connection type, includes screws. UL Listed E2527. Suitable for hazardous locations
Steel cover for conduit access fittings, designed for use with Appleton FM8 Unilet Conduit Outlet Bodies. Features a screw-in connection and includes a gasket. UL Listed for Class I, Division II hazardous locations, suitable for environments with flammable gases or vapors
APPLETON ELECTRIC
Steel cover for conduit access fittings, designed for use with Appleton FM8 Unilet Conduit Outlet Bodies. Features a screw-in connection and includes a gasket. UL Listed for Class I, Division II hazardous locations, suitable for environments with flammable gases or vapors
Steel cover for conduit access fittings, with a 1-1/4 in trade size and screw-in connection. Includes screws. Rated for hazardous locations. Complies with UL 514A. For use with Appleton Form 35 Unilet Conduit Outlet Bodies
APPLETON ELECTRIC
Steel cover for conduit access fittings, with a 1-1/4 in trade size and screw-in connection. Includes screws. Rated for hazardous locations. Complies with UL 514A. For use with Appleton Form 35 Unilet Conduit Outlet Bodies
Steel cover for use with Appleton FM8 Unilet conduit outlet bodies. Screw-in connection with included gasket and screws. Rated for hazardous locations. Complies with C22.2 No. 18.3
APPLETON ELECTRIC
Steel cover for use with Appleton FM8 Unilet conduit outlet bodies. Screw-in connection with included gasket and screws. Rated for hazardous locations. Complies with C22.2 No. 18.3
Aluminum cover with powder-coated finish for use with Appleton GRJS Series outlet boxes. Features screw-in connection for 1/2 in trade size round body. Includes mounting screws. UL 886 listed for hazardous locations
APPLETON ELECTRIC
Aluminum cover with powder-coated finish for use with Appleton GRJS Series outlet boxes. Features screw-in connection for 1/2 in trade size round body. Includes mounting screws. UL 886 listed for hazardous locations
Steel cover for use with Appleton FM7 Unilet conduit outlet bodies. Screw-in connection with included gasket and screws. UL Listed E2527 for Class I, Division II hazardous locations. Trade sizes 2-1/2 to 3 in
APPLETON ELECTRIC
Steel cover for use with Appleton FM7 Unilet conduit outlet bodies. Screw-in connection with included gasket and screws. UL Listed E2527 for Class I, Division II hazardous locations. Trade sizes 2-1/2 to 3 in