Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

3G Electric
Image not available
ARMSTRONGGeneral-Purpose Inline Circulator Pumps

ARMSTRONG General-Purpose Inline Circulator Pump

The ARMSTRONG HVAC Circulating Pump: 1/25 hp HP (SKU 110223-326, MPN 110223-326) is a general-purpose inline circulator pump for hydronic systems. It features a 120V AC nameplate voltage, flange connections, and a…

SKU 3G-OTH-83671

Also listed as: 110223326 · 110223 326

Brand
ARMSTRONG
Item
General-Purpose Inline Circulator Pump
Part Number
110223-326
Category
General-Purpose Inline Circulator Pumps
Available to Order
Also known as:110223-326ARMSTRONG
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

ARMSTRONG
Manufacturer Part Number
110223-326
Type
Stainless Steel, 3, 38 gpm, Inline
AC
120V
Max. Head
18 ft
System Type
Hydronic
Connection Type
Flange
Includes Volute
No Volute Included
Nameplate Voltage
120V AC

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

ARMSTRONG Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The ARMSTRONG HVAC Circulating Pump: 1/25 hp HP (SKU 110223-326, MPN 110223-326) is a general-purpose inline circulator pump for hydronic systems. It features a 120V AC nameplate voltage, flange connections, and a stainless steel construction. The pump delivers up to 38 gpm at 18 ft max. head and does not include a volute.

Frequently Asked Questions

What is the ARMSTRONG HVAC Circulating Pump 110223-326 used for?

This ARMSTRONG inline circulator pump is designed for hydronic heating and cooling systems. It circulates water in closed-loop applications such as commercial HVAC, radiant heating, and boiler systems. The 1/25 hp motor and 38 gpm flow rate suit medium-duty circulation tasks.

What are the specifications of the ARMSTRONG 110223-326 pump?

The ARMSTRONG 110223-326 is a 1/25 hp general-purpose inline circulator pump with a 120V AC nameplate voltage. It delivers up to 38 gpm at 18 ft max. head, features flange connections, and has a stainless steel construction. It is designed for hydronic systems and does not include a volute.

Where to buy the ARMSTRONG HVAC Circulating Pump 110223-326 worldwide?

3G Electric supplies the ARMSTRONG 110223-326 HVAC circulating pump to customers worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and a quote for your region.

How to install the ARMSTRONG inline circulator pump 110223-326?

Install the ARMSTRONG pump with the shaft horizontal and the electrical junction box accessible. Use flange gaskets and ensure proper pipe alignment to avoid stress. Wire the 120V AC motor per local codes. Purge air from the system before startup. Always follow the manufacturer's manual for torque and clearance specs.

Used in

Common applications for ARMSTRONG
Healthcare isolation rooms — Armstrong Calla 2820A sealed system tiles for acoustic control and cleanability
Commercial office ceilings — Armstrong Prelude main beams and cross tees for suspension framing
Hydronic heating systems — Armstrong E23.2 inline circulator pump for potable water circulation
Pump maintenance — Armstrong seal kit 8975002-374K for bearing assembly replacement in circulator pumps
Cleanroom environments — Armstrong Calla 1353N sealed system tiles with mold resistance and high light reflectance
General-purpose interiors — Armstrong Calla 2822AN ceiling tiles for 15/16 in grid with square tegular edge
Not sure this is the right part? Photo-identify it→

ARMSTRONG Products

3G Electric supplies ARMSTRONG general-purpose inline circulator pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories →Valves & Regulation →Motors & Drives →All Products →

Compatible alternatives & equivalents

More from ARMSTRONG

View all ARMSTRONG parts →
This general-purpose inline circulator pump is designed for potable water systems in commercial or industrial hydronic heating and cooling loops. It features a bronze construction, flange connections, and delivers 128 gpm at a 22 ft maximum head. The pump operates on 120V AC and has an 8 1/2 in face-to-face dimension. Note: volute not included
ARMSTRONG
This general-purpose inline circulator pump is designed for potable water systems in commercial or industrial hydronic heating and cooling loops. It features a bronze construction, flange connections, and delivers 128 gpm at a 22 ft maximum head. The pump operates on 120V AC and has an 8 1/2 in face-to-face dimension. Note: volute not included
ARMSTRONG
ARMSTRONG
This ARMSTRONG inline circulator pump is designed for potable water systems in hydronic heating and plumbing applications. It features a bronze construction, flange connections, and delivers up to 42 gpm at a maximum head of 32 ft. The pump operates on 120V AC and has a face-to-face dimension of 8-1/2 in. No volute is included
ARMSTRONG
ARMSTRONG
This general-purpose inline circulator pump is designed for potable water systems in hydronic heating and domestic water loops. It features a bronze construction, flange connections, and delivers 32 gpm at 29 ft max head with a 6 13/32 in face-to-face dimension. No volute is included
This ARMSTRONG general-purpose inline circulator pump is designed for potable water systems. It operates at 120V AC with a flow rate of 10 gpm and a maximum head of 5 ft, featuring a 6-inch face-to-face dimension and union connections. The pump is constructed with stainless steel and does not include a volute
ARMSTRONG
This ARMSTRONG general-purpose inline circulator pump is designed for potable water systems. It operates at 120V AC with a flow rate of 10 gpm and a maximum head of 5 ft, featuring a 6-inch face-to-face dimension and union connections. The pump is constructed with stainless steel and does not include a volute
ARMSTRONG
ARMSTRONG
This ARMSTRONG inline circulator pump is designed for potable water systems in closed-loop hydronic heating or cooling applications. It features a bronze construction with flange connections, delivering 38 gpm at a maximum head of 34 ft. The pump operates on 120V AC and has a 6 13/32 in face-to-face dimension. No volute is included

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first