Send a part number, a photo, or a whole BOM — we supply it and stand behind it. EXW Singapore — collect from our office.

3G Electric
ARMSTRONG INTERNATIONAL Standard Inverted-Bucket Steam Trap - Standard Inverted-Bucket Steam Traps
ARMSTRONG INTERNATIONALStandard Inverted-Bucket Steam Traps

ARMSTRONG INTERNATIONAL Standard Inverted-Bucket Steam Trap

The ARMSTRONG INTERNATIONAL Standard Inverted-Bucket Steam Trap is a cast-iron, in-line configured unit designed for horizontal installation. This model (MPN 883-100-250) features 1-inch FNPT connections, a maximum…

SKU 3G-OTH-70581

Also listed as: 883100250 · 883 100 250

Brand
ARMSTRONG INTERNATIONAL
Item
Standard Inverted-Bucket Steam Trap
Part Number
883-100-250
Category
Standard Inverted-Bucket Steam Traps
Available to Order
Also known as:883-100-250ARMSTRONG INTERNATIONAL
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.

Technical Specifications

ARMSTRONG INTERNATIONAL
Manufacturer Part Number
883-100-250
Type
3,500 lb/hr, Strainer Included
FNPT
1 in
Max.
250 psi
Configuration
In-line
Installation Orientation
Horizontal

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

ARMSTRONG INTERNATIONAL Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The ARMSTRONG INTERNATIONAL Standard Inverted-Bucket Steam Trap is a cast-iron, in-line configured unit designed for horizontal installation. This model (MPN 883-100-250) features 1-inch FNPT connections, a maximum capacity of 3,500 lb/hr, and a maximum operating pressure of 250 psi at temperatures up to 450°F, with an integrated strainer.

Frequently Asked Questions

What is the Armstrong International 883-100-250 steam trap used for?

This Armstrong International inverted-bucket steam trap removes condensate from steam lines in industrial heating and process systems. It is suitable for horizontal piping with 1-inch FNPT connections, handling up to 3,500 lb/hr at 250 psi and 450°F, with an integrated strainer.

What are the specifications of the Armstrong 883-100-250 steam trap?

The Armstrong International 883-100-250 is a cast-iron, in-line steam trap with 1-inch FNPT connections. It has a maximum capacity of 3,500 lb/hr, maximum pressure of 250 psi, and maximum temperature of 450°F. It requires horizontal installation and includes a built-in strainer.

Where to buy the Armstrong 883-100-250 steam trap worldwide?

3G Electric supplies the Armstrong International 883-100-250 steam trap worldwide. As a global industrial distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time on this cast-iron inverted-bucket steam trap.

How to install the Armstrong inverted-bucket steam trap?

Install the Armstrong International 883-100-250 steam trap horizontally in the pipeline with the inlet and outlet aligned. Ensure the strainer is clean before startup. Follow standard piping practices for steam traps: allow proper clearance for maintenance and check pressure/temperature ratings do not exceed 250 psi or 450°F.

Used in

Common applications for ARMSTRONG INTERNATIONAL
Steam distribution headers — Armstrong International inverted bucket steam traps (e.g., 883-075-250) for condensate removal at pressures up to 250 psi.
Corrosive condensate systems — Stainless steel Armstrong International traps (e.g., 1811-075-400) for resistance to acidic or high-purity condensate.
High-pressure steam lines — Armstrong International 1822-100-250 traps rated to 250 psi and 600°F for superheated steam applications.
Tracer line drainage — Armstrong International 1811 series traps with 1/2 in or 3/4 in connections for freeze protection and process temperature maintenance.
Steam system strainer protection — Armstrong International inline strainers (e.g., 304 stainless steel, 3/4 in NPT) to capture debris upstream of traps and valves.
HVAC and process equipment — Armstrong International inverted bucket traps for condensate removal from heat exchangers, coils, and unit heaters.
Not sure this is the right part? Photo-identify it→

ARMSTRONG INTERNATIONAL Products

3G Electric supplies ARMSTRONG INTERNATIONAL standard inverted-bucket steam traps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

More from ARMSTRONG INTERNATIONAL

View all ARMSTRONG INTERNATIONAL parts →
Cast iron, in-line configured steam trap with 1/2 inch FNPT connections. Horizontal installation. Maximum capacity 600 lb/hr, maximum pressure 150 psi, maximum temperature 450°F. Strainer not included. Used to automatically drain condensate from steam lines while preventing steam loss
ARMSTRONG INTERNATIONAL
Cast iron, in-line configured steam trap with 1/2 inch FNPT connections. Horizontal installation. Maximum capacity 600 lb/hr, maximum pressure 150 psi, maximum temperature 450°F. Strainer not included. Used to automatically drain condensate from steam lines while preventing steam loss
Cast-iron inverted-bucket steam trap with 1-inch FNPT connection, rated for 750 lb/hr capacity and 250 psi maximum pressure. In-line configuration for horizontal installation. Built-in strainer included. Used to drain condensate from steam lines while preventing steam loss in industrial steam systems
ARMSTRONG INTERNATIONAL
Cast-iron inverted-bucket steam trap with 1-inch FNPT connection, rated for 750 lb/hr capacity and 250 psi maximum pressure. In-line configuration for horizontal installation. Built-in strainer included. Used to drain condensate from steam lines while preventing steam loss in industrial steam systems
Cast-iron, in-line inverted-bucket steam trap with 1 in FNPT connections. Rated for 4000 lb/hr condensate capacity at maximum 30 psi and 450°F. Designed for horizontal installation to automatically drain condensate from steam lines while preventing steam loss. Strainer not included
ARMSTRONG INTERNATIONAL
Cast-iron, in-line inverted-bucket steam trap with 1 in FNPT connections. Rated for 4000 lb/hr condensate capacity at maximum 30 psi and 450°F. Designed for horizontal installation to automatically drain condensate from steam lines while preventing steam loss. Strainer not included
Steam Trap: Cast Iron, 1 in FNPT, 1,000 lb/hr, 30 psi Max., 450°F Max., Strainer Included (MPN 881-100-030)
ARMSTRONG INTERNATIONAL
Steam Trap: Cast Iron, 1 in FNPT, 1,000 lb/hr, 30 psi Max., 450°F Max., Strainer Included (MPN 881-100-030)
Cast iron inverted-bucket steam trap with 1 1/2 in FNPT connection, rated for 9,900 lb/hr condensate capacity at 30 psi maximum pressure and 450°F maximum temperature. In-line configuration for horizontal installation. Strainer not included. Used to discharge condensate from steam lines in process heating, heat exchangers, and steam mains
ARMSTRONG INTERNATIONAL
Cast iron inverted-bucket steam trap with 1 1/2 in FNPT connection, rated for 9,900 lb/hr condensate capacity at 30 psi maximum pressure and 450°F maximum temperature. In-line configuration for horizontal installation. Strainer not included. Used to discharge condensate from steam lines in process heating, heat exchangers, and steam mains

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first