ASHCROFT Pressure Transmitter: 0 psi to 500 psi, 4 to 20mA DC, Cable & Wire Leads
The ASHCROFT A2X Series Explosion-Proof-Rated Transmitter measures gauge pressure from 0 psi to 500 psi with a 4 to 20mA DC output and ±0.50% of Full Scale accuracy. It features a stainless steel housing, IP65 and…
SKU 3G-OTH-175385
Need installation or engineering help?
Ask a question
Product Description
The ASHCROFT A2X Series Explosion-Proof-Rated Transmitter measures gauge pressure from 0 psi to 500 psi with a 4 to 20mA DC output and ±0.50% of Full Scale accuracy. It features a stainless steel housing, IP65 and NEMA 4X ratings, and is Intrinsically Safe with Class II, Div 1 and 2, Group F, G safety rating. The transmitter includes a NIST-Traceable Calibration Certificate and uses an NPT process connection with conduit connection and wire leads.
Frequently Asked Questions
What is the ASHCROFT A2X pressure transmitter used for?
The ASHCROFT A2X explosion-proof-rated transmitter measures gauge pressure from 0 psi to 500 psi in hazardous industrial environments. It is suitable for oil and gas, chemical processing, and other applications requiring intrinsic safety with Class II, Div 1 and 2, Group F, G ratings.
What are the specifications of the ASHCROFT A2X pressure transmitter?
The ASHCROFT A2X transmitter has a 4 to 20mA DC output, ±0.50% of Full Scale accuracy, stainless steel housing, IP65 and NEMA 4X ratings, and an NPT process connection. It is intrinsically safe with overpressure of 1.2x range and burst pressure of 1.5x range.
Where to buy the ASHCROFT A2X pressure transmitter worldwide?
3G Electric supplies the ASHCROFT A2X pressure transmitter worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time on this explosion-proof-rated transmitter.
How to install the ASHCROFT A2X pressure transmitter?
Install the ASHCROFT A2X transmitter using the NPT process connection with conduit and wire leads. Ensure the area is classified for intrinsic safety (Class II, Div 1 and 2, Group F, G). Follow standard wiring practices for 4 to 20mA DC loops and verify the NIST-traceable calibration before commissioning.
Used in
Common applications for ASHCROFTASHCROFT Products
3G Electric supplies ASHCROFT explosion-proof with conduit connection & wire leads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.