ASHCROFT Pressure Transmitter: 0 psi to 500 psi, 4 to 20mA DC, Cable & Wire Leads
The ASHCROFT A2X Series Explosion-Proof-Rated Transmitter measures gauge pressure from 0 psi to 500 psi with a 4 to 20mA DC output and ±0.50% of Full Scale accuracy. It features a stainless steel housing, NPT process…
SKU 3G-OTH-175386
Need installation or engineering help?
Ask a question
Product Description
The ASHCROFT A2X Series Explosion-Proof-Rated Transmitter measures gauge pressure from 0 psi to 500 psi with a 4 to 20mA DC output and ±0.50% of Full Scale accuracy. It features a stainless steel housing, NPT process connection, and IP65 / NEMA 9 rating, with overpressure of 1.2x Range and burst pressure of 1.5x Range. This intrinsically safe transmitter is Class III, Div 1 and 2 rated, includes a NIST-Traceable Calibration Certificate, and comes with conduit connection and wire leads.
Frequently Asked Questions
What is the ASHCROFT A2X pressure transmitter used for?
The ASHCROFT A2X Series explosion-proof-rated transmitter measures gauge pressure from 0 psi to 500 psi in hazardous industrial environments. It is suitable for oil and gas, chemical processing, and other applications requiring intrinsically safe, Class III Div 1 and 2 rated instrumentation with a 4 to 20mA DC output.
What are the specifications of the ASHCROFT A2X transmitter?
The ASHCROFT A2X transmitter has a 0 psi to 500 psi range, 4 to 20mA DC output, ±0.50% of Full Scale accuracy, stainless steel housing, NPT process connection, IP65 / NEMA 9 rating, overpressure of 1.2x Range, and burst pressure of 1.5x Range. It includes a NIST-Traceable Calibration Certificate and is intrinsically safe.
Where to buy the ASHCROFT A2X pressure transmitter worldwide?
3G Electric supplies the ASHCROFT A2X pressure transmitter worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time on this explosion-proof-rated transmitter with conduit connection and wire leads.
How to install the ASHCROFT A2X explosion-proof transmitter?
Install the ASHCROFT A2X transmitter using the NPT process connection into a compatible port. Ensure the conduit connection and wire leads are properly sealed to maintain the IP65 / NEMA 9 rating. Follow standard hazardous-area wiring practices for intrinsically safe circuits. Refer to the manufacturer's manual for torque and wiring details.
Used in
Common applications for ASHCROFTASHCROFT Products
3G Electric supplies ASHCROFT explosion-proof with conduit connection & wire leads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.