ASHCROFT Pressure Transmitter: 0 psi to 30 psi, 1 to 5V DC, Cable & Wire Leads - Explosion-Proof with Conduit Connection & Wire Leads
ASHCROFTExplosion-Proof with Conduit Connection & Wire Leads

ASHCROFT Pressure Transmitter: 0 psi to 30 psi, 1 to 5V DC, Cable & Wire Leads

The ASHCROFT A2X Series Pressure Transmitter (0 psi to 30 psi) is an explosion-proof-rated transmitter with a conduit connection and wire leads, featuring a 1 to 5V DC output and ±0.50% of Full Scale accuracy. It has…

SKU 3G-OTH-175428

Brand
ASHCROFT
Item
Pressure Transmitter: 0 psi to 30 psi, 1 to 5V DC, Cable & Wire Leads
Category
Explosion-Proof with Conduit Connection & Wire Leads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

ASHCROFT
Manufacturer Part Number
A2XBF0415C230#G
Series
A2X
Type
Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9
DC
1 to 5V
Output
1 to 5V DC
Accuracy
±0.50% of Full Scale
IP Rating
IP65
NEMA Rating
4X
Overpressure
1.5x Range
Product Type
Explosion-Proof-Rated Transmitter
Safety Rating
Class II, Div 1 and 2, Group E, F, G
Burst Pressure
2x Range
Housing Material
Stainless Steel
Intrinsically Safe
Not Specified Intrinsically Safe
Pressure Type Measured
Gauge
Process Connection Type
NPT
NIST Traceable Certificate
NIST-Traceable Calibration Certificate Included
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

ASHCROFT Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The ASHCROFT A2X Series Pressure Transmitter (0 psi to 30 psi) is an explosion-proof-rated transmitter with a conduit connection and wire leads, featuring a 1 to 5V DC output and ±0.50% of Full Scale accuracy. It has a stainless steel housing, IP65 and NEMA 4X ratings, and a gauge pressure type with an NPT process connection. The unit offers overpressure of 1.5x Range and burst pressure of 2x Range, and is rated Class II, Div 1 and 2, Group E, F, G. A NIST-Traceable Calibration Certificate is included.

Frequently Asked Questions

What is the ASHCROFT A2X pressure transmitter used for?

The ASHCROFT A2X pressure transmitter is used for measuring gauge pressure from 0 psi to 30 psi in hazardous industrial environments. Its explosion-proof rating (Class II, Div 1 and 2, Group E, F, G) and IP65/NEMA 4X stainless steel housing make it suitable for oil and gas, chemical, and processing plants where safety and durability are critical.

What are the specifications of the ASHCROFT A2X pressure transmitter?

The ASHCROFT A2X series transmitter has a 0 psi to 30 psi range, 1 to 5V DC output, ±0.50% of Full Scale accuracy, NPT process connection, and stainless steel housing. It features IP65 and NEMA 4X ratings, overpressure of 1.5x range, burst pressure of 2x range, and includes a NIST-Traceable Calibration Certificate.

Where to buy the ASHCROFT A2X pressure transmitter worldwide?

You can source the ASHCROFT A2X pressure transmitter from 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time; we provide this transmitter as part of our extensive sourcing network.

How to install the ASHCROFT A2X pressure transmitter?

Install the ASHCROFT A2X pressure transmitter by connecting the NPT process connection to the system, ensuring proper sealing. Use the conduit connection and wire leads for electrical wiring to a 1 to 5V DC input. Follow standard explosion-proof installation practices for hazardous locations, and verify the NIST-Traceable Calibration Certificate before commissioning.

Used in

Common applications for ASHCROFT
Process control in chemical plants — ASHCROFT G2 series pressure transmitters with 4-20 mA output
Sanitary monitoring in food processing — ASHCROFT sanitary pressure transmitters with stainless steel fittings
Temperature measurement in oil and gas — ASHCROFT flanged thermowells rated to 1,000°F
Hydraulic system pressure monitoring — ASHCROFT G2 series transmitters with 1-5 V DC output
Hazardous location pressure sensing — ASHCROFT A2X explosion-proof transmitters with conduit connection
Steam system temperature protection — ASHCROFT threaded thermowells rated to 7,000 psi

ASHCROFT Products

3G Electric supplies ASHCROFT explosion-proof with conduit connection & wire leads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
Pressure Transmitter: 0 psi to 60 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0415C260#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 9; Output: 1 to 5V DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 60 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0415C260#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 9; Output: 1 to 5V DC; Overpressure: 1.5x Range.
Pressure Transmitter: 0 psi to 15 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0415C215#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 9; Output: 1 to 5V DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 15 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0415C215#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 9; Output: 1 to 5V DC; Overpressure: 1.5x Range.
Pressure Transmitter: 0 psi to 30 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0215C230#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 1 to 5V DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 30 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0215C230#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 1 to 5V DC; Overpressure: 1.5x Range.
Pressure Transmitter: 0 psi to 5 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0415C25#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 4X; Output: 1 to 5V DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 5 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0415C25#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 4X; Output: 1 to 5V DC; Overpressure: 1.5x Range.
Pressure Transmitter: 0 psi to 300 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0215C2300#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 9; Output: 1 to 5V DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 300 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0215C2300#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 9; Output: 1 to 5V DC; Overpressure: 1.5x Range.
Pressure Transmitter: 0 psi to 300 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0415C2300#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 1 to 5V DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 300 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0415C2300#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 1 to 5V DC; Overpressure: 1.5x Range.

More from ASHCROFT

View all ASHCROFT parts
Pressure Transmitter, 5,000 psi (MPN E2FA5NF0242CFX03F5000#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
ASHCROFT
Pressure Transmitter, 5,000 psi (MPN E2FA5NF0242CFX03F5000#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
Pressure Transmitter: 0 psi to 200 psi, 4 to 20mA DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0442C2200#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 4 to 20mA DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 200 psi, 4 to 20mA DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0442C2200#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 4 to 20mA DC; Overpressure: 1.5x Range.
Pressure Transmitter, 3,000 psi (MPN E2FA5NM0442CFX03F3000#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
ASHCROFT
Pressure Transmitter, 3,000 psi (MPN E2FA5NM0442CFX03F3000#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
Pressure Transmitter: 0 psi to 60 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0215C260#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 1 to 5V DC; Overpressure: 1.5x Range.
ASHCROFT
Pressure Transmitter: 0 psi to 60 psi, 1 to 5V DC, Cable & Wire Leads, IP65 /4X/IP65 /7/IP65 /9 (MPN A2XBF0215C260#G). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP65; Series: A2X; NEMA Rating: 7; Output: 1 to 5V DC; Overpressure: 1.5x Range.
Pressure Transmitter, 15 psi (MPN E2FC5NM0215CFX03FV&15#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 1 to 5V DC.
ASHCROFT
Pressure Transmitter, 15 psi (MPN E2FC5NM0215CFX03FV&15#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 1 to 5V DC.
Pressure Transmitter, 1,000 psi (MPN E2FA5NF0242CFX03F1000#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
ASHCROFT
Pressure Transmitter, 1,000 psi (MPN E2FA5NF0242CFX03F1000#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
ASHCROFT
ASHCROFT
Pressure Transmitter, 15 psi (MPN E2FC5NM0242CFX03F15#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
Pressure Transmitter, 60 psi (MPN E2FA5NF0242CFX03F60#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.
ASHCROFT
Pressure Transmitter, 60 psi (MPN E2FA5NF0242CFX03F60#). Key specifications — Process Connection Type: NPT; Intrinsically Safe: Not Specified Intrinsically Safe; Housing Material: Stainless Steel; IP Rating: IP66; Electrical Connection: 1/2 in NPT Conduit with Cable; Series: E2F; NEMA Rating: 4X; Output: 4 to 20mA.