Beckett GeniSys® 7505 120V Oil Burner Control
Beckett GeniSys® 7505 primary safety control for residential and light commercial oil heating systems. Manages burner operation with flame detection, thermostat compatibility, and diagnostic capabilities.
SKU 3G-BKT-00027
Also listed as: 4020002 · 40200 02
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
Beckett GeniSys® 7505 primary safety control for residential and light commercial oil heating systems. Manages burner operation with flame detection, thermostat compatibility, and diagnostic capabilities.
Frequently Asked Questions
What is the Beckett GeniSys 7505 oil burner control used for?
The Beckett GeniSys 7505 is a primary safety control for residential and light commercial oil heating systems. It manages burner operation, flame detection, and thermostat compatibility, with diagnostic capabilities to improve system reliability and troubleshooting.
What are the specifications of the Beckett GeniSys 7505?
The GeniSys 7505 operates on 102–132 Vac input, 60 Hz, with motor output of 120 Vac at 10 FLA and 60 LRA. It features a 15-second lockout time, igniter output of 120 Vac at 3 A, and solenoid valve output of 120 Vac at 1 A. Approvals include UL372 and CSA C22.2 No. 199.
Where to buy the Beckett GeniSys 7505 in Singapore?
3G Electric supplies the Beckett GeniSys 7505 oil burner control to Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this model.
How to install the Beckett GeniSys 7505 oil burner control?
Installation should follow the manufacturer's wiring diagram and local codes. Ensure power is off, connect line and load wires per the terminal labels, and verify thermostat and flame sensor connections. After mounting, test for proper lockout timing and flame response before leaving the system operational.
Key Features
- 120 VAC primary safety control rated for residential and light commercial applications
- Compatible with GeniSys® CAD Cell Flame Detector Kit 7006U
- Front-mounted 24 VAC thermostat terminals for mechanical and power-stealing thermostats
- Interrupted ignition with 15-second lockout cycle
- Programmable pre-purge and post-purge timing via GeniSys® 52082 Contractor Tool or BeckettLink® Pro 7652
- Diagnostic memory storing last 15 burner cycles
- Dual motor relays with welded relay protection and redundancy
- Three status indicator lights for system monitoring
- Technician pump prime mode for service operations
- Water-resistant design for standard environments
- Potted GeniSys® 7575 variant available for high-moisture applications
- 5-year warranty coverage
- Replaces Honeywell R8184G (7505a) and R7184B (7505b) models
Used in
Common applications for BeckettBeckett Products
3G Electric supplies Beckett controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.