Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

BENCHMARK SCIENTIFIC Incubator: Forced Air, 2.3 cu ft Capacity, 21 1/4 in x 21 in x 39 3/8 in - Refrigerated Incubators
BENCHMARK SCIENTIFICRefrigerated Incubators

BENCHMARK SCIENTIFIC Incubator: Forced Air, 2.3 cu ft Capacity, 21 1/4 in x 21 in x 39 3/8 in

The BENCHMARK SCIENTIFIC H2265-HC is a BOD refrigerated incubator with forced air circulation. It features a digital control, a temperature range starting at 0 °C, and a uniformity of +/-0.5 °C with an accuracy of…

SKU 3G-OTH-417153

Brand
BENCHMARK SCIENTIFIC
Item
Incubator: Forced Air, 2.3 cu ft Capacity, 21 1/4 in x 21 in x 39 3/8 in
Category
Refrigerated Incubators
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

BENCHMARK SCIENTIFIC
Manufacturer Part Number
H2265-HC
Type
2.3 cu ft Capacity, 21 1/4 in x 21 in x 39 3/8 in, BOD
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

BENCHMARK SCIENTIFIC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The BENCHMARK SCIENTIFIC H2265-HC is a BOD refrigerated incubator with forced air circulation. It features a digital control, a temperature range starting at 0 °C, and a uniformity of +/-0.5 °C with an accuracy of +/-1 °C. This 2.3 cu ft unit operates on 115V AC.

Frequently Asked Questions

What is the BENCHMARK SCIENTIFIC H2265-HC refrigerated incubator used for?

The BENCHMARK SCIENTIFIC H2265-HC is a BOD (Biochemical Oxygen Demand) refrigerated incubator used for wastewater testing, microbiology, and environmental sample incubation. Its forced air circulation ensures uniform temperature control, making it suitable for laboratory applications requiring precise, stable conditions.

What are the specifications of the BENCHMARK SCIENTIFIC H2265-HC incubator?

The BENCHMARK SCIENTIFIC H2265-HC is a 2.3 cu ft forced air BOD incubator with digital control. It operates on 115V AC, has a temperature range starting at 0 °C, uniformity of +/-0.5 °C, and accuracy of +/-1 °C. Dimensions are 21 1/4 in x 21 in x 39 3/8 in.

Where to buy the BENCHMARK SCIENTIFIC H2265-HC incubator worldwide?

3G Electric supplies the BENCHMARK SCIENTIFIC H2265-HC refrigerated incubator to customers worldwide. We handle full logistics, customs clearance, and delivery to your facility. Contact us for a quote and lead time on this forced air BOD incubator.

How to maintain a BENCHMARK SCIENTIFIC forced air incubator?

Regularly clean the interior and door gasket with a mild disinfectant. Ensure the forced air fan and vents are free of debris to maintain uniform airflow. Calibrate the digital controller periodically against a certified thermometer. Always follow the manufacturer's manual for specific maintenance intervals.

Used in

Common applications for BENCHMARK SCIENTIFIC
Life science research — Benchmark Scientific microcentrifuge rotors for DNA/RNA extraction and protein purification.
Clinical diagnostics — Benchmark Scientific dry bath blocks for sample incubation and enzyme reactions.
Pharmaceutical quality control — Benchmark Scientific tube rotator for mixing reagents and dissolution testing.
Industrial microbiology — Benchmark Scientific mini CO2 incubated shaker for cell culture and fermentation studies.
Histology and pathology — Benchmark Scientific slide dryer for rapid drying of microscope slides after staining.
General laboratory mixing — Benchmark Scientific 3D rocker for gentle agitation of blots and gels in hybridization ovens.

BENCHMARK SCIENTIFIC Products

3G Electric supplies BENCHMARK SCIENTIFIC refrigerated incubators. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
BENCHMARK SCIENTIFIC Incubator: Forced Air, 0.75 cu ft Capacity, 14 1/2 in x 13 1/4 in x 18 3/4 in (MPN H2200-H). Key specifications — Refrigerated: Non-Refrigerated; Minimum Temperature Setting: Ambient +5 °C; Temperature Accuracy Tolerance: +/-0.5 °C; Temperature Uniformity: +/-1.5 °C; Manufacturer Part Number: H2200-H; Brand: BENCHMARK SCIENTIFIC; Display Type: Digital; Voltage: 100 to 240V AC.
BENCHMARK SCIENTIFIC
BENCHMARK SCIENTIFIC Incubator: Forced Air, 0.75 cu ft Capacity, 14 1/2 in x 13 1/4 in x 18 3/4 in (MPN H2200-H). Key specifications — Refrigerated: Non-Refrigerated; Minimum Temperature Setting: Ambient +5 °C; Temperature Accuracy Tolerance: +/-0.5 °C; Temperature Uniformity: +/-1.5 °C; Manufacturer Part Number: H2200-H; Brand: BENCHMARK SCIENTIFIC; Display Type: Digital; Voltage: 100 to 240V AC.
BENCHMARK SCIENTIFIC Incubator: Forced Air, 0.7 cu ft Capacity, 14 1/2 in x 13 1/4 in x 18 3/4 in (MPN H2300-HC2). Key specifications — Incubator Type: Carbon Dioxide; Refrigerated: Refrigerated; Minimum Temperature Setting: Ambient -10 °C; Temperature Accuracy Tolerance: +/-0.25 °C @ 37 °C; Temperature Uniformity: +/-0.5 °C @ 37 °C; Manufacturer Part Number: H2300-HC2; Brand: BENCHMARK SCIENTIFIC; Display Type: Digital.
BENCHMARK SCIENTIFIC
BENCHMARK SCIENTIFIC Incubator: Forced Air, 0.7 cu ft Capacity, 14 1/2 in x 13 1/4 in x 18 3/4 in (MPN H2300-HC2). Key specifications — Incubator Type: Carbon Dioxide; Refrigerated: Refrigerated; Minimum Temperature Setting: Ambient -10 °C; Temperature Accuracy Tolerance: +/-0.25 °C @ 37 °C; Temperature Uniformity: +/-0.5 °C @ 37 °C; Manufacturer Part Number: H2300-HC2; Brand: BENCHMARK SCIENTIFIC; Display Type: Digital.
BENCHMARK SCIENTIFIC Incubator: Dual, 4.8 cu ft Capacity, 75°C Max Temp Setting, Multipurpose (MPN H2505-130). Key specifications — Incubator Type: Multipurpose; Refrigerated: Non-Refrigerated; Minimum Temperature Setting: Ambient +5 °C; Temperature Accuracy Tolerance: +/-0.25 °C; Temperature Uniformity: +/-0.25 °C; Manufacturer Part Number: H2505-130; Brand: BENCHMARK SCIENTIFIC; Display Type: Digital.
BENCHMARK SCIENTIFIC
BENCHMARK SCIENTIFIC Incubator: Dual, 4.8 cu ft Capacity, 75°C Max Temp Setting, Multipurpose (MPN H2505-130). Key specifications — Incubator Type: Multipurpose; Refrigerated: Non-Refrigerated; Minimum Temperature Setting: Ambient +5 °C; Temperature Accuracy Tolerance: +/-0.25 °C; Temperature Uniformity: +/-0.25 °C; Manufacturer Part Number: H2505-130; Brand: BENCHMARK SCIENTIFIC; Display Type: Digital.
BENCHMARK SCIENTIFIC Incubator: Dual, 1.5 cu ft Capacity, 75°C Max Temp Setting, Multipurpose (MPN H2505-40). Key specifications — Incubator Type: Multipurpose; Refrigerated: Non-Refrigerated; Minimum Temperature Setting: Ambient +5 °C; Temperature Accuracy Tolerance: +/-0.25 °C; Temperature Uniformity: +/-0.25 °C; Manufacturer Part Number: H2505-40; Brand: BENCHMARK SCIENTIFIC; Display Type: Digital.
BENCHMARK SCIENTIFIC
BENCHMARK SCIENTIFIC Incubator: Dual, 1.5 cu ft Capacity, 75°C Max Temp Setting, Multipurpose (MPN H2505-40). Key specifications — Incubator Type: Multipurpose; Refrigerated: Non-Refrigerated; Minimum Temperature Setting: Ambient +5 °C; Temperature Accuracy Tolerance: +/-0.25 °C; Temperature Uniformity: +/-0.25 °C; Manufacturer Part Number: H2505-40; Brand: BENCHMARK SCIENTIFIC; Display Type: Digital.
BENCHMARK SCIENTIFIC Incubator: Dual, 2.5 cu ft Capacity, 75°C Max Temp Setting, Multipurpose (MPN H2505-70). Key specifications — Incubator Type: Multipurpose; Refrigerated: Non-Refrigerated; Minimum Temperature Setting: Ambient +5 °C; Temperature Accuracy Tolerance: +/-0.25 °C; Temperature Uniformity: +/-0.25 °C; Manufacturer Part Number: H2505-70; Brand: BENCHMARK SCIENTIFIC; Display Type: Digital.
BENCHMARK SCIENTIFIC
BENCHMARK SCIENTIFIC Incubator: Dual, 2.5 cu ft Capacity, 75°C Max Temp Setting, Multipurpose (MPN H2505-70). Key specifications — Incubator Type: Multipurpose; Refrigerated: Non-Refrigerated; Minimum Temperature Setting: Ambient +5 °C; Temperature Accuracy Tolerance: +/-0.25 °C; Temperature Uniformity: +/-0.25 °C; Manufacturer Part Number: H2505-70; Brand: BENCHMARK SCIENTIFIC; Display Type: Digital.
BINDER Incubator: Forced Air, 1.87 cu ft Capacity, 24 3/4 in x 33 7/8 in x 25 in, Digital, 2 Shelves (MPN 9020-0312). Key specifications — attr1027521: Refrigerated; attr1030162: 4 °C; attr1027529: 0.1 %; attr1027530: 0.3 +/- K @ 37 °C; attr1027476: 9020-0312; attr1027480: BINDER; attr1027487: Digital; attr1027531: 100/120V.
BINDER
BINDER Incubator: Forced Air, 1.87 cu ft Capacity, 24 3/4 in x 33 7/8 in x 25 in, Digital, 2 Shelves (MPN 9020-0312). Key specifications — attr1027521: Refrigerated; attr1030162: 4 °C; attr1027529: 0.1 %; attr1027530: 0.3 +/- K @ 37 °C; attr1027476: 9020-0312; attr1027480: BINDER; attr1027487: Digital; attr1027531: 100/120V.

More from BENCHMARK SCIENTIFIC

View all BENCHMARK SCIENTIFIC parts
BENCHMARK SCIENTIFIC Incubator: Forced Air, 0.75 cu ft Capacity, 14 1/2 in x 13 1/4 in x 18 3/4 in (MPN H2200-HC). Key specifications — attr1027521: Refrigerated; attr1030162: Ambient -15 °C; attr1027529: +/-0.5 °C; attr1027530: +/-1.5 °C; attr1027476: H2200-HC; attr1027480: BENCHMARK SCIENTIFIC; attr1027487: Digital; attr1027531: 100 to 240V AC.
BENCHMARK SCIENTIFIC
BENCHMARK SCIENTIFIC Incubator: Forced Air, 0.75 cu ft Capacity, 14 1/2 in x 13 1/4 in x 18 3/4 in (MPN H2200-HC). Key specifications — attr1027521: Refrigerated; attr1030162: Ambient -15 °C; attr1027529: +/-0.5 °C; attr1027530: +/-1.5 °C; attr1027476: H2200-HC; attr1027480: BENCHMARK SCIENTIFIC; attr1027487: Digital; attr1027531: 100 to 240V AC.