Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

BRAH ELECTRIC Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 3 Wire, 100 A Amps - Obsolete GE-Style Fusible Bus Plugs
BRAH ELECTRICObsolete GE-Style Fusible Bus Plugs

BRAH ELECTRIC Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 3 Wire, 100 A Amps

The BRAH ELECTRIC Bus Plug (SKU BEC3610, MPN BEC3610) is an obsolete GE-style fusible bus plug designed to fit Gen Electric/ABB Armor Clad busway. It is a 3-phase, 3-wire, 100 A unit rated for 600V AC with a J fuse…

SKU 3G-OTH-141707

Also listed as: BEC 3610 · BEC-3610

Brand
BRAH ELECTRIC
Item
Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 3 Wire, 100 A Amps
Category
Obsolete GE-Style Fusible Bus Plugs
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

BRAH ELECTRIC
Manufacturer Part Number
BEC3610
Type
Fusible, 600V
Amps
100 A
Wire
3
Phase
3

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

BRAH ELECTRIC Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The BRAH ELECTRIC Bus Plug (SKU BEC3610, MPN BEC3610) is an obsolete GE-style fusible bus plug designed to fit Gen Electric/ABB Armor Clad busway. It is a 3-phase, 3-wire, 100 A unit rated for 600V AC with a J fuse class. This product includes weather stripping not included and is identified by catalog number AC1363RJ.

Frequently Asked Questions

What is the BRAH ELECTRIC Bus Plug used for?

The BRAH ELECTRIC Bus Plug (MPN BEC3610) is used to connect electrical loads to GE Armor Clad busway systems in industrial plants. It is a fusible, 3-phase, 3-wire plug rated 100 A at 600V AC, suitable for obsolete GE-style busway installations requiring a J fuse class.

What are the specifications of the BRAH ELECTRIC Bus Plug?

The BRAH ELECTRIC Bus Plug (SKU 3G-OTH-141707) is a fusible, 600V AC unit rated 100 A, 3-phase, 3-wire, with a J fuse class. It fits GE Armor Clad busway, includes weather stripping not included, and is identified by catalog number AC1363RJ. The manufacturer part number is BEC3610.

Where to buy BRAH ELECTRIC Bus Plug in worldwide?

3G Electric supplies the BRAH ELECTRIC Bus Plug (MPN BEC3610) worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.

How to install the BRAH ELECTRIC Bus Plug?

Install the BRAH ELECTRIC Bus Plug by first de-energizing the busway. Align the plug with the GE Armor Clad busway opening, engage the hook, and secure the clamp. Ensure the J-class fuses are properly seated. Follow NFPA 70E safety practices and consult a qualified electrician.

Used in

Common applications for BRAH ELECTRIC
Industrial manufacturing plants — BRAH ELECTRIC bus plugs for GE Flex-A-Plug busway systems in 240V distribution
Commercial building retrofits — BRAH ELECTRIC BIP3610N replacing obsolete Eaton Cutler-Hammer bus plugs in 600V POW-R-WAY systems
Utility substations — BRAH ELECTRIC BES3603G for Siemens BD busway with Class H fuses at 600V
Data center power distribution — BRAH ELECTRIC BEB3203GW for GE Spectra Series busway at 240V with Class R fuses
Oil and gas facilities — BRAH ELECTRIC BEC3610GNW for GE Armor Clad busway in 600V three-phase, four-wire with ground applications
Warehouse lighting circuits — BRAH ELECTRIC BES3210NW for Siemens BD busway at 240V with 100 A ampacity

BRAH ELECTRIC Products

3G Electric supplies BRAH ELECTRIC obsolete ge-style fusible bus plugs. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
BRAH ELECTRIC Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 3 Wire, 60 A Amps, 600V (MPN BEC3606W)
BRAH ELECTRIC
BRAH ELECTRIC Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 3 Wire, 60 A Amps, 600V (MPN BEC3606W)
BRAH ELECTRIC Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 4 Wire, 60 A Amps, 600V (MPN BEC3606N)
BRAH ELECTRIC
BRAH ELECTRIC Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 4 Wire, 60 A Amps, 600V (MPN BEC3606N)
BRAH ELECTRIC Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 4 Wire, 100 A Amps, 600V (MPN BEC3610N)
BRAH ELECTRIC
BRAH ELECTRIC Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 4 Wire, 100 A Amps, 600V (MPN BEC3610N)
BRAH ELECTRIC Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 3 Wire, 100 A Amps, 600V (MPN BEC3610W)
BRAH ELECTRIC
BRAH ELECTRIC Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 3 Wire, 100 A Amps, 600V (MPN BEC3610W)
BRAH ELECTRIC Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 4 Wire, 30 A Amps, 600V (MPN BEC3603NW)
BRAH ELECTRIC
BRAH ELECTRIC Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 4 Wire, 30 A Amps, 600V (MPN BEC3603NW)
BRAH ELECTRIC Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 4 Wire, 100 A Amps, 600V (MPN BEC3610NW)
BRAH ELECTRIC
BRAH ELECTRIC Bus Plug: Fits Gen Electric/ABB Armor Clad, Fusible, 3 Phase, 4 Wire, 100 A Amps, 600V (MPN BEC3610NW)

More from BRAH ELECTRIC

View all BRAH ELECTRIC parts
Fusible bus plug for use with GE Armor Clad Busway in industrial power distribution systems. Rated 600V AC, 3-phase, 4-wire with ground. H classification. Weather stripping not included
BRAH ELECTRIC
Fusible bus plug for use with GE Armor Clad Busway in industrial power distribution systems. Rated 600V AC, 3-phase, 4-wire with ground. H classification. Weather stripping not included
Obsolete GE-style fusible bus plug for tapping power from GE Armor Clad Busway. Rated 240V AC, 3-phase, 4-wire with ground. Accepts J-type fuses. Suitable for industrial power distribution in facilities with existing GE busway systems
BRAH ELECTRIC
Obsolete GE-style fusible bus plug for tapping power from GE Armor Clad Busway. Rated 240V AC, 3-phase, 4-wire with ground. Accepts J-type fuses. Suitable for industrial power distribution in facilities with existing GE busway systems
Fusible bus plug rated 100 A at 240V, 3-phase, 4-wire, with Type FVK fusing and R configuration. Includes weather stripping. Designed for use in industrial power distribution systems requiring obsolete GE-style components
BRAH ELECTRIC
Fusible bus plug rated 100 A at 240V, 3-phase, 4-wire, with Type FVK fusing and R configuration. Includes weather stripping. Designed for use in industrial power distribution systems requiring obsolete GE-style components
This obsolete GE-style fusible bus plug is rated for 600V and includes weather stripping. It is designed to connect electrical loads to low-amp busway systems in industrial power distribution applications
BRAH ELECTRIC
This obsolete GE-style fusible bus plug is rated for 600V and includes weather stripping. It is designed to connect electrical loads to low-amp busway systems in industrial power distribution applications
This obsolete GE-style fusible bus plug is rated for 600V and replaces models SL462RGI, SL462RGJI, and SL462RGRI. It is designed for use in industrial power distribution systems, providing a fused connection point for electrical loads
BRAH ELECTRIC
This obsolete GE-style fusible bus plug is rated for 600V and replaces models SL462RGI, SL462RGJI, and SL462RGRI. It is designed for use in industrial power distribution systems, providing a fused connection point for electrical loads
This obsolete GE-style fusible bus plug operates at 240V and is designed for use with General Electric/ABB Spectra low-amp busway systems. It replaces models SL322RGI, SL322RGJI, and SL322RGRI. The unit includes weather stripping and is intended for J-type fusing. Typical applications include industrial power distribution in manufacturing and commercial facilities
BRAH ELECTRIC
This obsolete GE-style fusible bus plug operates at 240V and is designed for use with General Electric/ABB Spectra low-amp busway systems. It replaces models SL322RGI, SL322RGJI, and SL322RGRI. The unit includes weather stripping and is intended for J-type fusing. Typical applications include industrial power distribution in manufacturing and commercial facilities
Fusible bus plug designed for use with GE Armor Clad Busway in industrial power distribution systems. Rated 600V AC, 3-phase, 4-wire with ground. Suitable for branch circuit protection in manufacturing, data centers, and commercial facilities
BRAH ELECTRIC
Fusible bus plug designed for use with GE Armor Clad Busway in industrial power distribution systems. Rated 600V AC, 3-phase, 4-wire with ground. Suitable for branch circuit protection in manufacturing, data centers, and commercial facilities
Obsolete GE-style fusible bus plug rated 600V. Replaces SL361RGI, SL361RGJI, and SL361RGRI models. Designed for use in industrial power distribution systems to provide a fused disconnect point for branch circuits. Includes weather stripping
BRAH ELECTRIC
Obsolete GE-style fusible bus plug rated 600V. Replaces SL361RGI, SL361RGJI, and SL361RGRI models. Designed for use in industrial power distribution systems to provide a fused disconnect point for branch circuits. Includes weather stripping