BUSSMANN Fuse: GDA Series, Fast-Acting, 400 mA, 250 V AC, Non-Indicating
The BUSSMANN GDA Series is a fast-acting cylindrical fuse rated at 400 mA and 250 V AC, with a non-indicating design in a 5 mm x 20 mm form factor (MPN GDA-400MA). It is equivalent to fuse series GDA, S501, 216, and GSD.
SKU 3G-OTH-26590
Also listed as: GDA400MA · GDA 400MA
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
The BUSSMANN GDA Series is a fast-acting cylindrical fuse rated at 400 mA and 250 V AC, with a non-indicating design in a 5 mm x 20 mm form factor (MPN GDA-400MA). It is equivalent to fuse series GDA, S501, 216, and GSD.
Frequently Asked Questions
What is the BUSSMANN GDA-400MA fuse used for?
The BUSSMANN GDA-400MA is a fast-acting cylindrical fuse rated at 400 mA and 250 V AC, designed to protect sensitive electronic circuits from overcurrent. Its 5 mm x 20 mm non-indicating form factor suits industrial control panels, power supplies, and instrumentation where precise, rapid interruption is required.
What are the specifications of the BUSSMANN GDA-400MA fuse?
The BUSSMANN GDA-400MA is a fast-acting, non-indicating fuse rated at 400 mA and 250 V AC, with a 5 mm x 20 mm cylindrical body. It belongs to the GDA series and is equivalent to fuse series S501, 216, and GSD. The manufacturer part number is GDA-400MA.
Where to buy the BUSSMANN GDA-400MA fuse worldwide?
3G Electric supplies the BUSSMANN GDA-400MA fuse to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your location. Contact us to order this fast-acting 400 mA, 250 V AC fuse for your application.
How to select the correct BUSSMANN GDA-400MA fuse for my circuit?
To select the correct BUSSMANN GDA-400MA fuse, verify your circuit's operating voltage does not exceed 250 V AC and that the continuous current is below 400 mA. Ensure the fast-acting characteristic matches your load's inrush profile. The 5 mm x 20 mm size fits standard fuse holders. Consult a qualified engineer for critical applications.
Used in
Common applications for BUSSMANNBUSSMANN Products
3G Electric supplies BUSSMANN fast-acting cylindrical fuses. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.
