BUSSMANN Fuse: Class T, LPT Series, Time-Delay, 40 A, 600 V AC, 300 V DC
The BUSSMANN LPT Series fuse is a Class T, time-delay cylindrical fuse rated at 40 A, 600 V AC, and 300 V DC. This non-indicating fuse is designed for overcurrent protection in industrial equipment. The MPN is LPT-40.
SKU 3G-OTH-24960
Also listed as: LPT40 · LPT 40
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
The BUSSMANN LPT Series fuse is a Class T, time-delay cylindrical fuse rated at 40 A, 600 V AC, and 300 V DC. This non-indicating fuse is designed for overcurrent protection in industrial equipment. The MPN is LPT-40.
Frequently Asked Questions
What is the BUSSMANN LPT-40 fuse used for?
The BUSSMANN LPT-40 is a Class T, time-delay cylindrical fuse rated 40 A, 600 V AC, and 300 V DC. It provides overcurrent protection in industrial equipment such as motor control centers, panelboards, and switchgear where high interrupting capacity and compact size are required.
What are the specifications of the BUSSMANN LPT-40 fuse?
The BUSSMANN LPT-40 is a Class T, time-delay, non-indicating fuse rated 40 A, 600 V AC, and 300 V DC. It is part of the LPT series with MPN LPT-40. This cylindrical fuse is designed for overcurrent protection in industrial applications requiring high interrupting capacity.
Where to buy the BUSSMANN LPT-40 fuse worldwide?
3G Electric supplies the BUSSMANN LPT-40 fuse worldwide. As a global industrial equipment distributor, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time. We source and deliver BUSSMANN fuses to customers globally.
How to select the correct BUSSMANN LPT-40 fuse for an application?
To select the BUSSMANN LPT-40 fuse, verify the system voltage does not exceed 600 V AC or 300 V DC and the continuous load current is below 40 A. Ensure the fuse holder is Class T rated. For time-delay applications, the LPT series handles inrush currents typical of motors and transformers.