Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

CANARM Panel Fan: Direct Drive, 14 in Blade, 1/3 hp, 2,190 cfm, 230/460V AC, 3 ph - Hazardous Location Direct-Drive Panel Exhaust Fans
CANARMHazardous Location Direct-Drive Panel Exhaust Fans

CANARM Panel Fan: Direct Drive, 14 in Blade, 1/3 hp, 2,190 cfm, 230/460V AC, 3 ph

The CANARM Panel Fan: Direct Drive (SKU 3G-OTH-80538, MPN P14-4M) is a hazardous location direct-drive panel exhaust fan with a 14-inch blade, 1/3 hp, and 2,190 cfm at 230/460V AC, three-phase. It features a…

SKU 3G-OTH-80538

Also listed as: P144M · P14 4M

Brand
CANARM
Item
Panel Fan: Direct Drive, 14 in Blade, 1/3 hp, 2,190 cfm, 230/460V AC, 3 ph
Category
Hazardous Location Direct-Drive Panel Exhaust Fans
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

CANARM
Manufacturer Part Number
P14-4M
Type
1/3 hp, 2,190 cfm, 3 ph, Totally Enclosed
AC
230/460V
Blade
14 in
Assembled
Assembled
Guard Type
Intake
Motor Type
DC
Frame Finish
Powder Coated
Frame Material
Steel
Motor Enclosure
Totally Enclosed Air Over
Enclosure Design
Totally Enclosed Motor
Motor Insulation
Class 1
Number of Speeds
Variable
Nameplate Voltage
230/460V AC
Guard Type Subheads
With Intake Guards
Hazardous Location Class
Class I, Div 1, Group C and D

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CANARM Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The CANARM Panel Fan: Direct Drive (SKU 3G-OTH-80538, MPN P14-4M) is a hazardous location direct-drive panel exhaust fan with a 14-inch blade, 1/3 hp, and 2,190 cfm at 230/460V AC, three-phase. It features a powder-coated steel frame, a totally enclosed air-over motor with Class 1 insulation, and variable-speed operation. This assembled unit is rated for Class I, Div 1, Groups C and D, and Class II, Div 1, Groups F and G, and includes intake guards.

Frequently Asked Questions

What is the CANARM P14-4M panel fan used for?

The CANARM P14-4M is a hazardous location direct-drive panel exhaust fan designed for Class I, Div 1, Groups C and D, and Class II, Div 1, Groups F and G environments. It moves 2,190 cfm at 1/3 hp and is suitable for ventilating areas with flammable gases, combustible dusts, or volatile vapors.

What are the specifications of the CANARM P14-4M panel fan?

The CANARM P14-4M has a 14-inch blade, 1/3 hp motor, 2,190 cfm airflow, and operates on 230/460V AC three-phase power. It features a powder-coated steel frame, totally enclosed air-over motor with Class 1 insulation, variable-speed capability, and intake guards. It is assembled and rated for hazardous locations.

Where to buy the CANARM P14-4M panel fan worldwide?

3G Electric supplies the CANARM P14-4M panel fan worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time; we source and deliver this hazardous location fan to any country.

How to install the CANARM P14-4M hazardous location panel fan?

Install the CANARM P14-4M in a panel cutout matching the fan frame, securing it with bolts. Ensure the electrical supply matches the 230/460V AC three-phase nameplate. Use conduit rated for the hazardous class. Follow local codes and the manufacturer's manual for wiring and grounding. Variable-speed control requires a compatible drive.

Used in

Common applications for CANARM
Warehouse ventilation — CANARM direct-drive panel exhaust fans (e.g., P24-1RS9M115) for removing heat and fumes
Manufacturing plant air circulation — CANARM belt-drive blowers (e.g., BI2731000M) for high-volume air movement
Commercial kitchen exhaust — CANARM downblast exhausters (e.g., ALX165-DD033EC) for roof-mounted ventilation
Industrial floor cooling — CANARM mobile circulating fans (e.g., HVR36) for spot cooling in workshops
Office or retail space ventilation — CANARM wall-mount oscillating fans (e.g., CA30OSC-C) for general air circulation
Equipment cooling — CANARM ceiling-mount fans (e.g., HAF18-ZO) for targeted airflow over machinery

CANARM Products

3G Electric supplies CANARM hazardous location direct-drive panel exhaust fans. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
MARKEL Hazardous-Location Electric Heater: 3.6 kW Watt Output, Gray, 480V AC, 3-phase (MPN FEP-3648-3RA)
MARKEL
MARKEL Hazardous-Location Electric Heater: 3.6 kW Watt Output, Gray, 480V AC, 3-phase (MPN FEP-3648-3RA)
MARKEL Hazardous-Location Electric Heater: 7.6 kW Watt Output, Gray, 480V AC, 3-phase (MPN FEP-7648-3RA)
MARKEL
MARKEL Hazardous-Location Electric Heater: 7.6 kW Watt Output, Gray, 480V AC, 3-phase (MPN FEP-7648-3RA)
MARKEL Hazardous-Location Electric Heater: 7.6 kW Watt Output, Gray, 240V AC, 1-phase (MPN FEP-7624-1RA)
MARKEL
MARKEL Hazardous-Location Electric Heater: 7.6 kW Watt Output, Gray, 240V AC, 1-phase (MPN FEP-7624-1RA)

More from CANARM

View all CANARM parts
Panel Mounted Hazardous Location Exhaust Fan: Direct Drive, 18 in Blade, 1/3 hp, 3,200 cfm, 1 ph (MPN P18-4)
CANARM
Panel Mounted Hazardous Location Exhaust Fan: Direct Drive, 18 in Blade, 1/3 hp, 3,200 cfm, 1 ph (MPN P18-4)
Panel Fan: Direct Drive, 16 in Blade, 1/3 hp, 2,580 cfm, 230/460V AC, 3 ph, Totally Enclosed (MPN P16-4M)
CANARM
Panel Fan: Direct Drive, 16 in Blade, 1/3 hp, 2,580 cfm, 230/460V AC, 3 ph, Totally Enclosed (MPN P16-4M)
Panel Mounted Hazardous Location Exhaust Fan: Direct Drive, 16 in Blade, 1/3 hp, 2,580 cfm, 1 ph (MPN P16-4)
CANARM
Panel Mounted Hazardous Location Exhaust Fan: Direct Drive, 16 in Blade, 1/3 hp, 2,580 cfm, 1 ph (MPN P16-4)
Panel Fan: Direct Drive, 24 in Blade, 1/3 hp, 5,520 cfm, 230/460V AC, 3 ph, Totally Enclosed (MPN P24-4M)
CANARM
Panel Fan: Direct Drive, 24 in Blade, 1/3 hp, 5,520 cfm, 230/460V AC, 3 ph, Totally Enclosed (MPN P24-4M)
Panel Mounted Hazardous Location Exhaust Fan: Direct Drive, 20 in Blade, 1/3 hp, 3,640 cfm, 1 ph (MPN P20-4)
CANARM
Panel Mounted Hazardous Location Exhaust Fan: Direct Drive, 20 in Blade, 1/3 hp, 3,640 cfm, 1 ph (MPN P20-4)
Panel Fan: Direct Drive, 18 in Blade, 1/3 hp, 3,200 cfm, 230/460V AC, 3 ph, Totally Enclosed (MPN P18-4M)
CANARM
Panel Fan: Direct Drive, 18 in Blade, 1/3 hp, 3,200 cfm, 230/460V AC, 3 ph, Totally Enclosed (MPN P18-4M)
Panel Mounted Hazardous Location Exhaust Fan: Direct Drive, 24 in Blade, 1/3 hp, 5,520 cfm, 1 ph (MPN P24-4)
CANARM
Panel Mounted Hazardous Location Exhaust Fan: Direct Drive, 24 in Blade, 1/3 hp, 5,520 cfm, 1 ph (MPN P24-4)
Panel Fan: Direct Drive, 20 in Blade, 1/3 hp, 3,640 cfm, 230/460V AC, 3 ph, Totally Enclosed (MPN P20-4M)
CANARM
Panel Fan: Direct Drive, 20 in Blade, 1/3 hp, 3,640 cfm, 230/460V AC, 3 ph, Totally Enclosed (MPN P20-4M)