Honeywell VK 8525 M 1502 U gas block - Gas Controls
HoneywellGas Controls

Honeywell VK 8525 M 1502 U gas block

The Honeywell VK 8525 M 1502 U is a gas block control valve for natural gas applications, handling up to 3.12 m³/h at 5 mbar with G 1/2 external thread connections. Operating on 24 Vdc supply voltage, it integrates…

SKU 3G-CBM-00430

Also listed as: BLO 05361 · BLO-05361

Brand
Honeywell
Item
VK 8525 M 1502 U gas block
Category
Gas Controls
UNSPSC
40142201 — Gas regulators
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Honeywell
connections
G 1/2 external thread
capacity max
3200 L/h at 5 mbar delta p
capacity min
500 L/h
hold voltage
12 Vdc ±1.5 Vdc
supply voltage
24 Vdc -4/+6 Vdc
opening voltage
22 Vdc ±1.5 Vdc
ambient temperature
-5 to 70°C
capacity natural gas
3.12 m³/h at 5 mbar
power consumption motor
6 W
power consumption safety
4 W

Datasheet Content

VK8525M(R) MODULATING GAS CONTROL “GASTEP” INSTRUCTION SHEET Main gas connection Connections with G 1/2” external thread fitted with nuts according to ISO 228-1 in combination with applicable sealing(s) withstand the torsion and bending stress of EN 161 group 1 Capacity Natural gas versions: 3,12 m3/h air minimum at 5 mbar pressure drop LPG versions without regulator: 1,8 m3/h air minimum at 5 mbar pressure drop LPG versions with regulator (specials): 1,2 m3/h air at specific conditions: - inlet pressure 50 mbar (nominal) - outlet pressure 16 mbar See also capacity curves on page 3. In the capacity curves, min. and max. are specified. APPLICATION Operating pressure ranges The Gastep gas control has been developed for modulating Natural gas: 15 ... 30 mbar gas fired appliances. LP gas: 25 ... 60 mbar The application of the Gastep gas control requires specific control electronics in order to fulfil the safety requirements. Maximum inlet pressure 60 mbar DESCRIPTION Timing opening time : < 1 second The Gastep gas control comprises: closing time : < 1 second - an electrically operated on/off safety valve class B - an electrically operated steppermotor based modulating Valve classification main valve Safety valve: class B - an optional integrated gas pressure regulator in Main valve: class B * accordance with class C requirement of EN 88. The Gastep gas control meets the EN 161 and the EN 88 *) The main valve is classified as safety valve class B only, if used in combination with a specific electronic system, Subject to change without notice. All rights reserved requirements. performing additional safety checks to the judgement of the notified body and meeting the requirements for safety SPECIFICATIONS electronics according EN298 ! Model VK8525M: modulating gas control without pressure Electrical data regulator Safety valve operator VK8525MR: modulating gas control with pressure regulator Opening voltage: 22 Vdc ± 1.5 Vdc Dimensions Hold voltage (regulated): 12 Vdc ± 1.5 Vdc See fig. 1. Power consumption: 4 W maximum Connection: 2.8 x 0.8 mm tabs Ambient temperature -5 ... 70°C Main valve steppermotor Supply voltage: 24 Vdc - 4/+6Vdc Power consumption: 6 W maximum Connection: JST XHDP-06V-1 1 EN1R-9184 0903RA-NE Outlet G 1/2" Stepper motor Pressure test points Cap screw 12 hex Adjustment screw 7 hex Pressure regulator Safety operator Inlet G 1/2" Fig. 1. Dimensional drawing EN1R-9184 0903RA-NE 2 6 Qmax. 3200 L/h delta p 5 mbar Qmin. 500L/h air 5 4 Delta p in mbar Qmin. 500L/h 3 2 1 0 0 500 1000 1500 2000 2500 3000 3500 Q in L /h (air) Fig. 2. Nominal capacity curve Natural Gas (regulated versions) 6 Qmax. 1200 L/h delta p 5 mbar Qmin. 300 L/h air 5 4 Delta P in mbar Qmin. 300L/h 3 2 1 0 0 200 300 400 600 800 1000 1200 1400 Q in L /h (air) Fig. 3. Nominal capacity curve LP Gas (regulated versions) 3 EN1R-9184 0903RA-NE • INSTALLATION With the main burner in operation, paint all pipe joints (including adapters) and gas control inlet and outlet with a rich soap and water solution or an approved leak IMPORTANT detection fluid. Take care that installer is a trained experienced • If another gas leak is detected, tighten adapter screws, service person. joints and pipe connections. Turn off gas supply before starting installation. • Replace the part if gas leak can not be stopped. Disconnect power supply to prevent electrical shock and/or equipment damage. Take care that dirt cannot enter the gas control…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Honeywell Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Honeywell VK 8525 M 1502 U is a gas block control valve for natural gas applications, handling up to 3.12 m³/h at 5 mbar with G 1/2 external thread connections. Operating on 24 Vdc supply voltage, it integrates safety and modulation functions in residential and commercial heating systems.

Frequently Asked Questions

What is the Honeywell VK 8525 M 1502 U gas block used for?

The Honeywell VK 8525 M 1502 U is a modulating gas control valve for natural gas applications. It integrates an electrically operated safety valve and a stepper-motor-based main valve, making it suitable for residential and commercial gas-fired heating systems that require precise modulation and safety functions.

What are the specifications of the Honeywell VK 8525 M 1502 U?

The Honeywell VK 8525 M 1502 U has G 1/2 external thread connections, a natural gas capacity of 3.12 m³/h at 5 mbar pressure drop, and operates on a 24 Vdc supply voltage. The safety valve opening voltage is 22 Vdc ±1.5 Vdc, hold voltage is 12 Vdc ±1.5 Vdc, and ambient temperature range is -5 to 70°C.

Where to buy the Honeywell VK 8525 M 1502 U in Singapore?

3G Electric supplies the Honeywell VK 8525 M 1502 U gas block to Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for a quotation and lead time on this item.

How to install the Honeywell VK 8525 M 1502 U gas block?

Installation should follow the manufacturer's instruction sheet. Ensure the gas supply is off, connect G 1/2 external threads with appropriate seals to withstand torsion per EN 161 group 1. Wire the 24 Vdc supply to the stepper motor and safety operator tabs. Commission by checking opening voltage and pressure test points.

Used in

Common applications for Honeywell
Commercial kitchen and inflight-catering steam boilers — RM7890 / RM7895 flame relays with UV detection
Food-processing ramp-and-dwell ovens — DBC2000E / DBC2100E controllers
Hotel and hospital boiler plants — VR8205 combination gas controls
Petrochemical tank-farm heating — V4xxx gas-valve bodies with ML7420 actuators
Retrofit swap-outs from legacy Fireye / Satronic — Honeywell replacement kits

Honeywell Products

3G Electric supplies Honeywell gas controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Gas block VK 8525 M 1510 U
Honeywell
Gas block VK 8525 M 1510 U
VK 4100 C 1026 U gas block
Honeywell
VK 4100 C 1026 U gas block
Gas block VK 4115 V 1352 U
Honeywell
Gas block VK 4115 V 1352 U
Gas block VK 4115 F 1237 U
Honeywell
Gas block VK 4115 F 1237 U
Gas block VK 4115 F 1229 U
Honeywell
Gas block VK 4115 F 1229 U
Gas block VK 4105 C 1025 U
Honeywell
Gas block VK 4105 C 1025 U

More from Honeywell

View all Honeywell parts
Honeywell
Honeywell
VK 4105 M 2071 U gas block
Honeywell
Honeywell
Gas block VK 4100 C 1000 U
Honeywell
Honeywell
Thermocouple switch V44/46/86/88
Honeywell
Honeywell
Gas block VK 4105 C 1009 U
Honeywell
Honeywell
Gas block V 8600 C 1053 U
Honeywell
Honeywell
Gas block VK 4105 C 1090 U
Honeywell
Honeywell
Gas block VK 4105 C 1041 U
Gas block VK 4105 N 2039 U
Honeywell
Gas block VK 4105 N 2039 U