Supco Current and voltage data logger
Supco current and voltage data logger for HVAC diagnostics captures up to 10,750 data points with sampling intervals from 1 second to 18 hours. Operating from -40°C to 65°C with ±0.5°C accuracy and 19-20 month…
SKU 3G-CBM-01282
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
Supco current and voltage data logger for HVAC diagnostics captures up to 10,750 data points with sampling intervals from 1 second to 18 hours. Operating from -40°C to 65°C with ±0.5°C accuracy and 19-20 month battery life, it serves field technicians and system commissioning workflows.
Frequently Asked Questions
What is the Supco current and voltage data logger used for?
The Supco LCV data logger is used for HVAC diagnostics, including monitoring compressor and fan run cycles, troubleshooting intermittent problems, and verifying power conditions. It simultaneously records AC current and voltage, making it ideal for field technicians and system commissioning workflows in commercial and industrial settings.
What are the specifications of the Supco LCV data logger?
The Supco LCV logger measures AC current from 0 to 300 Amps with ±5% accuracy and AC voltage from 0 to 500 Volts with ±1 V accuracy. It stores up to 10,750 points for both parameters, with sampling intervals from 1 second to 18 hours. Operating temperature ranges from -40°C to 65°C using a lithium battery, with ±0.5°C temperature accuracy.
Where to buy the Supco LCV data logger in Singapore?
3G Electric supplies the Supco LCV current and voltage data logger to Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for pricing and lead time on this HVAC diagnostic tool, which supports field technicians with simultaneous current and voltage recording.
How to install the Supco LCV data logger for HVAC diagnostics?
To install the Supco LCV logger, connect the supplied clamp probe to the conductor under test and the voltage leads to the circuit. Use the LOGiT PC software (p/n LLS, not included) to set sampling intervals from 1 second to 18 hours. Ensure the logger is within its operating temperature range and use a lithium battery for -40°C to 65°C environments.
Used in
Common applications for SupcoSupco Products
3G Electric supplies Supco hvac equipment. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.