Danfoss TMVX thermostatic expansion valve for R404A refrigeration systems with 5/8" UNF inlet and 3/4" UNF outlet. Features 12 mm bulb diameter, 1.5 m capillary length, and ~3 K static superheat. Suitable for…

SKU 3G-CBM-01709

Also listed as: CRE 04008 · CRE-04008

Brand
Danfoss
Item
TMVX R404 TMVX00108 expansion valve
Category
Refrigeration
UNSPSC
40101704 — Condensing units
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Danfoss
type
TMVX thermostatic expansion valve
inlet
5/8" UNF
outlet
3/4" UNF
refrigerant
R404A
bulb diameter
12 mm
capillary length
1.5 m
static superheat
~3 K
external equalization
7/16" UNF

Datasheet Content

Series TMV THERMOSTATIC EXPANSION VALVES INTERCHANGEABLE ORIFICE CARTRIDGE PRODUCT DATA Features • TMV / TMVBL: with internal pressure equalisation; for single injection in installations with one or more cooling circuits • TMVX / TMVXBL: with external pressure equalisation; for optimal evaporation effectiveness in all applications. Obligatory for multiple injection by liquid distributors • Combi adsorber charge The same valve can be used for different refrigerants (see table on page 2) Controller charge is high sensitive and responsive TMVX thus lowest possible level of superheat can be achieved Charge is not sensitive to effects of temperature on the capillary tube and valve head Damping characteristic results in stable control behaviour • Suitable for systems with hot gas defrosting • Adjustable superheat setting TMVXBL • Flare connections: TMV, TMVX • Flare / solder connections: TMVBL, TMVXBL • Extreme durable due to stainless steel head and Application stainless steel diaphragm welded using protective gas • Interchangeable orifice cartridges Thermostatic expansion valves series TMV are used in general refrigeration and for original equipment. • Refrigerants: R134a, R401A, R12 R22, R407C, R407A, R422D Plants with one or more circuits such as refrigerated cabinets R404A, R507A, R402A, R407B, R502 even with cramped mounting conditions, ice and cream R410A machines, milk cooling units, water chillers, vehicle air conditioning systems, cold stores, and air conditioning systems. Specification Nominal capacity range 0.52 to 22.4 kW R22 (small orifice graduation for Materials optimal control behaviour, interchangeable orifice Body brass cartridges) Thermal head stainless steel Evaporating temperature range see table on page 2 Connection solder: copper Maximum pressure PS see table on page 2 flare: brass Maximum test pressure PF see table on page 2 Max. ambient temperature 100 °C Max. bulb temperature 140 °C Static superheat approx. 3 K Length of capillary tube 1.5 m Bulb diameter 12 mm Copyright © 2009 Honeywell GmbH • Subject to change without notice EN0H-1900GE23 R0709 SERIES TMV Thermal Charges and Temperature Ranges 1. Adsorber charge 2. Adsorber charge with pressure limiting performance MOP Refrigerant Evaporation PS PF Refri- Evaporation MOP PS PF temperature (bar(a)) (bar(a)) gerant temperature (bar(a)) (bar(a)) range range R134a, R401A, +15 °C to -30 °C 34 37.4 R134a, +5 °C to -30 °C MOP A +15 °C 34 37.4 R12 R401A, -10 °C to -30 °C MOP A ±0 °C 29 31.9 R12 R22, R407C, +15 °C to -45 °C 36 39.6 R407A, R422D R22, +5 °C to –45 °C MOP A +15 °C 36 39.6 R407C, R404A, R507A, ±0 °C to -50 °C 36 39.6 -10 °C to -45 °C MOP A ±0 °C 29 31.9 R407A, R402A, R407B, +15 °C to -30 °C 36 39.6 R422D -27 °C to -45 °C MOP A -18 °C 29 31.9 R502 R404A, -10 °C to -50 °C MOP A ±0 °C 36 39.6 R407C +15 °C to -30 °C 36 39.6 R507A, -20 °C to -50 °C MOP A -10 °C 34 37.4 R410A +15 °C to -20 °C 40 44 R402A, Further refrigerants on request. R407B, -27 °C to -50 °C MOP A -18 °C 34 37.4 R502 Thermal systems with adsorber charge are completely insensitive to effects of temperature on the capillary tube and Further refrigerants and MOP on request valve head. It reacts only according to the temperature of the bulb. Thus, Honeywell TMV valves with combi adsorber charge work absolutely reliable, even in icy condition or while defrosting using hot gas. Capacities Nominal capacity (kW)* Type Orifice size R134a R22 R407C R422D R404A R507A R410A 0.3 0.36 0.52 0.50 0.36 0.36 0.36 0.62 0.5 0.69 0.99 0.95 0.67 0.68 0.69 1.2 0.7 1.0 1.4 1.3 0.92 0.97 0.98 1.6 1.0 1.4 2.0 1.9 1.3 1.4 1.4 2.4 TMV 1.5 2.2 3.2 3.1 2.2 2.2 2.3 3.8 TMVX 2.0 2.9 4.0 3.9 2.7 2.8 2.9 4.8 TMVBL 2.5 4.0 5.8 5.6 3.9 4.1 4.1 6.9 TMVXBL 3.0 6.6 9.3 8.9 6.3 6.5 6.6 11.1 3.5 8.7 12.2 11.7 8.3 8.6 8.7 14.6 4.5 11.8 17.0 16.4 11.3 12.0 12.1 20.3 4.75 15.9 22.4 21.6 15.3 15.8 15.9 26.8 * Capacities are based on t0 = +4 °C, tc = +38 °C and 1 K subcooled liquid refrigerant entering the valve. For other operating conditions see capacity charts in Honeywell catalogue or consult the Honeywell software. Dimensions and Weights Type Connections Weight (kg) Inlet Outlet Pressure (B) (A) equaliser (C) TMV 5/8" UNF 3/4" UNF - approx. 0.35 TMVX 5/8" UNF 3/4" UNF 7/16" UNF approx. 0.36 5/8" UNF 12 mm ODF - TMVBL approx. 0.33 5/8" UNF 1/2" ODF - 5/8" UNF 12 mm ODF 6 mm ODF TMVXBL approx. 0.34 5/8" UNF 1/2" ODF 1/4" ODF EN0H-1900GE23 R0709 2 Honeywell GmbH • Subject to change without notice…
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Danfoss Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Danfoss TMVX thermostatic expansion valve for R404A refrigeration systems with 5/8" UNF inlet and 3/4" UNF outlet. Features 12 mm bulb diameter, 1.5 m capillary length, and ~3 K static superheat. Suitable for commercial refrigeration applications requiring precise flow control.

Frequently Asked Questions

What is the Danfoss TMVX R404 TMVX00108 expansion valve used for?

The Danfoss TMVX thermostatic expansion valve is used in commercial refrigeration systems, including refrigerated cabinets, ice cream machines, milk cooling units, water chillers, cold stores, and air conditioning systems. It provides precise flow control for R404A refrigerant in applications requiring external pressure equalisation.

What are the specifications of the Danfoss TMVX00108 expansion valve?

The Danfoss TMVX00108 has a 5/8" UNF inlet and 3/4" UNF outlet, with a 12 mm bulb diameter and 1.5 m capillary length. It features ~3 K static superheat, external equalisation at 7/16" UNF, and is designed for R404A refrigerant. The valve body is brass with a stainless steel thermal head.

Where to buy the Danfoss TMVX00108 expansion valve in Singapore?

3G Electric supplies the Danfoss TMVX00108 expansion valve to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for a quotation and lead time on this R404A thermostatic expansion valve.

How to install the Danfoss TMVX expansion valve?

Install the Danfoss TMVX valve with the bulb mounted on a horizontal suction line after the evaporator outlet. Ensure the capillary tube is not exposed to excessive heat. The valve features adjustable superheat setting and external equalisation connection at 7/16" UNF. Follow standard refrigeration best practices for brazing and pressure testing.

Used in

Common applications for Danfoss
Light-oil industrial burners — OD / OD-H nozzles as scheduled replacement parts
Heating-boiler oil-supply circuits — BFP 10L / 11L / 41L pumps and coupling kits
Burner-rack solenoid valves — EV and EVR series for oil and gas shut-off
Legacy plant troubleshooting — matching a failed burner nameplate to correct Danfoss nozzle/pump combination
Refrigeration pressure controls — KP / RT series for secondary-refrigerant loops

Danfoss Products

3G Electric supplies Danfoss refrigeration. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Danfoss
Danfoss
Regulator TMVXBL R410 TMVXBL00218
Danfoss
Danfoss
Regulator TMVXBL R404 1/4" TMVXBL00208
Pressure regulator TMV R404 TMV00008
Danfoss
Pressure regulator TMV R404 TMV00008
Pressure regulator TMVX R134A TMVX00105
Danfoss
Pressure regulator TMVX R134A TMVX00105
Danfoss
Danfoss
Regulator TMVXBL R404 6mm TMVXBL00108
Pressure regulator TMV R134A TMV00005
Danfoss
Pressure regulator TMV R134A TMV00005

More from Danfoss

View all Danfoss parts
Calibrated orifice 3.5 TMVD00006 for TMV/TMVX-TMVBL/TMVXBL
Danfoss
Calibrated orifice 3.5 TMVD00006 for TMV/TMVX-TMVBL/TMVXBL
Compressor DANFOSS SH-140 A4ALC
Danfoss
Compressor DANFOSS SH-140 A4ALC
DANFOSS SH-380 A4ABE compressor
Danfoss
DANFOSS SH-380 A4ABE compressor
Compressor DANFOSS SH-295 A4ABE
Danfoss
Compressor DANFOSS SH-295 A4ABE
DANFOSS SZ-120 S4VC compressor
Danfoss
DANFOSS SZ-120 S4VC compressor
DANFOSS SH-300 B4ABE compressor
Danfoss
DANFOSS SH-300 B4ABE compressor
Pressure reducer TS2 068Z3400
Danfoss
Pressure reducer TS2 068Z3400
Compressor DANFOSS SH-240 A4ABE
Danfoss
Compressor DANFOSS SH-240 A4ABE