Delta VM3 RL 2.4 is an oil burner fuel pump unit with integrated solenoid valve, operating at 3500 rpm with a pressure range of 10-25 bar and factory setting of 20 ±0.3 bar. The 32 mm hub and 150 µm filter support…

SKU 3G-CBM-01902

Also listed as: DEL 05131 · DEL-05131

Brand
Delta
Item
Pump VM3 RL 2.4
Category
Oil Pumps
UNSPSC
40151524 — Oil pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Delta
type
Oil burner fuel unit with solenoid valve
model
VM3 RL 2.4
series
VM1-VM4U flanged
standard
DIN 24220, EN 225
coil options
F84 380V 50-60Hz, 230V 50-60Hz, 110V 50-60Hz, 24V 50-60Hz, 24V 95Hz, 24V DC, 12V DC
pressure range
10-25 bar
hub diameter mm
32
shaft diameter mm
8
rotation speed rpm
3500
pressure setting bar
20 ±0.3
standard filter mesh
150µ
nozzle port connection
G 1/8
inlet return connection
G 1/4
standard filter area cm2
20
pressure gauge connection
G 1/8

Datasheet Content

 Oil burners fuel unit with solenoid valve VM1 - VM4U flanged Printed in Italy - DE101/0102                                  The DELTA fuel unit is an efficient modern oil burner pump with compact design and since its mounting flange, hub and shaft sizes are manufactured to international standards (DIN 24220, EN 225), it can be 10 fitted to every oil burner. Features 1 High suction capability.   Suitable for one or two pipe systems. 9 Self priming.  2  Reliable pressure and positive cut-off. 8 Solenoid valve incorporated.  Special shaft seal.   Silent operation. 7 Low power absorption. 3  Easily installed and adjusted.  4 Pressure and vacuum gauge ports. Applications 5 6 The DELTA fuel unit type VM is designed for pumping oil in high pressure oil burners and transfer pump applications. From the suction side, the gears pass the oil to the WARNING pressure chamber, where it comes up against the head of the piston. Due to the build up of pressure, the piston It must not be used to pump water or acid. is forced back against the pressure regulating spring. The flow of pressurized oil is interrupted by an incorporated solenoid valve (10), and can, therefore, be Operation opened following the start of the motor (pre-purge), or interrupted before stopping the motor itself (instant shut- The VM fuel unit consists of a pump, solenoid valve, off of the flame preventing the nozzle dripping). The filter and pressure regulator valve housed within one excessive oil discharges to the return side (or by-passes casting. The pumping action is obtained from two spur in the one pipe version). It will be realized of course that gears (2), one of which is connected to the drive shaft the spring tension, which is varied by the regulator screw (3). The pump casting provides the various oil ways, for (1), regulates the pressure of oil required. the suction (6), return (5) and nozzle (9) ports. Pressure The pump can be converted from the single pipe version (8) and vacuum (7) gauge ports are also provided. to the two pipe version, fitting the by-pass plug (4) in the The VM unit is available in two pipe and one pipe return port. version. Both versions are self priming. On start up, the rotating gears purge the air from the suction chamber, through a vent groove in the piston to the return line in two pipe version, and through the nozzle line (after the solenoid valve opening) in one pipe version. On initial commissioning, it is possible to bleed the air more quickly, through the pressure gauge. Because a vacuum now exists oil, due to atmospheric pressure, enters the suction chamber through the filter. Printed in Italy - DE102/0102 Pump identification VM 1 R L 2 4 P F Pump type Nozzle capacity (see graphs) Rotation (seen from shaft end) R = clockwise L = counter clockwise Nozzle line (seen from cover) R = right L = left Pipes system 1 = one pipe 2 = two pipes Pressure ranges Factory setting 3 = 2 ÷ 10 bar 4 ±0,3 bar 4 = 4 ÷ 15 bar 10 ±0,3 bar 5 = 8 ÷ 20 bar 15 ±0,3 bar 6 = 10 ÷ 25 bar 20 ±0,3 bar Special versions U = cover type U with filter inox 65 cm² mesh 110µ without pressure and vacuum gauge L = cover type L with filter nylon 9 cm² mesh 150µ (only VM1) P = auxiliary pressure port K = nozzle port type K (4mm shorter) Coil type F = F84 coil with connector plug M = M8 coil with flexible metal conduit Technical specifications Oil viscosity ………………………………… 2 ÷ 50 cSt Oil temperature …………………………….. 60° C max Power consumption ………………………. See graphs Nozzle capacity …………………………….. See graphs Suction line vacuum ………………………. 0,5 bar max Suction line pressure ……………….…….. 0,7 bar max Return line pressure ……………………….1,5 bar max Rotation speed ……………………….……. 3500 rpm max Standard filter ……………………………… Nylon, mesh 150µ, 20cm² Dimensions …………………………………. Hub ø32, shaft ø8 (DIN 24220) Optional : flange hub ø54, shaft da 7/16” Connections ………………………………... Inlet – return : G ¼” Nozzle port : G1/8” Pressure – vacuum gauge : G1/8” Weight ……………………………………….. gr. 1100 Coil specifications ………………………… F84 380V 50-60Hz 230V 50-60Hz M8 230V 50-60Hz L=700mm 110V 50-60Hz 24V 50-60Hz 230V 50-60Hz L=260mm 24V 95Hz 24V DC 110V 60Hz L=700mm 12V DC 24V 50Hz L=300mm L=300mm L=400mm 24V 50Hz L=700mm L=500mm L=700mm 24V 50Hz L=700mm L=1000mm L=1600mm 24V DC L=700mm Printed in Italy - DE103/0102 Nozzle capacity Power consumption Visc. 5 cSt (1.4° E) L/h 2800 RPM 125 Visc. 5 cSt (1.4° E) Watts 2800 RPM 100 200 VM4 75 VM4 150 VM3 VM3 50 100 VM2 VM2 VM1 25 50 VM1 5 10 15 20 25 Bar 5 10 15 20 25 Bar 88 ÷ 98 DELTA 10 Cod. F84 230V/50-60Hz 11VA s.c. 102 14…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Delta Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Delta VM3 RL 2.4 is an oil burner fuel pump unit with integrated solenoid valve, operating at 3500 rpm with a pressure range of 10-25 bar and factory setting of 20 ±0.3 bar. The 32 mm hub and 150 µm filter support reliable fuel delivery in heating systems.

Frequently Asked Questions

What is the Delta VM3 RL 2.4 oil pump used for?

The Delta VM3 RL 2.4 is an oil burner fuel unit designed for pumping oil in high-pressure oil burners and transfer pump applications. It is commonly used in heating systems, including residential and commercial boilers, where reliable fuel delivery and integrated solenoid valve control are required.

What are the specifications of the Delta VM3 RL 2.4?

The Delta VM3 RL 2.4 operates at 3500 rpm with a pressure range of 10-25 bar and a factory setting of 20 ±0.3 bar. It features a 32 mm hub, 8 mm shaft, 150 µm filter, and coil options including 230V 50-60Hz and 24V DC. It conforms to DIN 24220 and EN 225 standards.

Where to buy the Delta VM3 RL 2.4 in Singapore?

3G Electric supplies the Delta VM3 RL 2.4 oil pump to customers in Singapore. We handle logistics, customs clearance, and delivery to your site. Contact our team for pricing and lead time on this model.

How to install the Delta VM3 RL 2.4 oil pump?

Installation should follow the manufacturer's guidelines: ensure the pump is mounted securely using the standard flange, connect suction and return lines per the one- or two-pipe system, and adjust the pressure regulator screw to the desired setting. Always verify the solenoid valve wiring matches the coil voltage.

Used in

Common applications for Delta
Oil burner heating systems — Delta VM1 and VM2 fuel unit pumps delivering 35–55 l/h at 20 bar pressure setting
Industrial lubrication circuits — Delta A-series and A2-series pumps with 130 µm stainless steel strainers at 10 bar pressure
Hydraulic equipment integration — Delta AD-series pumps rated 3500 rpm with 32 mm hub diameter for modular system assembly
Burner nozzle supply — Delta fuel units with G1/8" nozzle port and solenoid valve integration for atomization control
Replacement pump specification — Delta cable assemblies (700 mm, 3-core) for retrofit and maintenance of existing burner equipment
Multi-stage heating plant operation — Delta VM2 models with 150 µm nylon filtration for continuous-duty burner fuel supply

Delta Products

3G Electric supplies Delta oil pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Delta
Delta
Pump VM3 LR 2.4
Pump VM1 RL 2.4
Delta
Pump VM1 RL 2.4
Pump VM2 RL 2.4
Delta
Pump VM2 RL 2.4
Pump VM1 LL 2.4
Delta
Pump VM1 LL 2.4
Pump VM4 RL 2,4
Delta
Pump VM4 RL 2,4
Pump VM2 LL 2.4
Delta
Pump VM2 LL 2.4

More from Delta

View all Delta parts
Delta
Delta
VM3 LL 2.4 pump
Delta
Delta
Cover joint V
Delta
Delta
Pump VM1 LL 2.4 2P
Delta
Delta
Sieve S
Delta
Delta
Universal pump VU2
Delta
Delta
24 V coil for VU1
Delta
Delta
Cap + seal for pump filter (type A)
Delta
Delta
Pump VM3 RR 2.4