Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

DTekGaz Gas detection central unit DIN rail 1 probe
DTekGazGas Detection

DTekGaz Gas detection central unit DIN rail 1 probe

DTekGaz gas detection central unit monitors toxic and explosive gases across one conventional zone via DIN rail mounting. Delivers dual alarms at 8% LEL (120 ppm) and 13% LEL (200 ppm) with integrated fault detection…

SKU 3G-CBM-02006

Also listed as: DTK 08010 · DTK-08010

Brand
DTekGaz
Item
Gas detection central unit DIN rail 1 probe
Category
Gas Detection
UNSPSC
41113117 — Single gas monitors
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

DTekGaz
type
gas detection central unit
zones
1 conventional zone
alarm 1
8% LEL (120 ppm)
alarm 2
13% LEL (200 ppm)
mounting
DIN rail
gas types
toxic and/or explosive
alarm general
20% LEL (300 ppm)
probe channels
1
fault detection
probe interruption, short-circuit, degradation

Datasheet Content

BX180 Centrale de détection gaz modulaire V. 10 1 zone conventionnelle 3G-CBM-02006 La NOUVELLE centrale BX180 a été projetée à partir de la version précédente pour détecter de manière polyvalente les éventuelles fuites de gaz dans le domaine industriel. Grâce à la possibilité de connecter une sonde à distance, elle détecte la présence de gaz toxiques et/ou explosifs. La présence de questo et d’autres perspicacités rendent la BX180 idéale pour: l’usage domestique, les applications industrielles et de petits parkings souterrains. Détection de gaz La centrale présente trois niveaux de danger qui sont: 1° alarme est fixée pour toutes les sondes à 8 % de la L.I.E. (120ppm) 2° alarme est fixée pour toutes les sondes à 13 % de la L.I.E. (200ppm) 3° Alarme générale est fixée à 20 % de la L.I.E. (300ppm) D’autres éléments rendent cette centrale extrêmement polyvalente et fiable par exemple avec une série de micro-interrupteurs il est possible de: Sélectionner ou supprimer la sonde en panne Sélectionner le type de gaz à détecter: toxique ou explosif Choisir le fonctionnement du relais: en mode continue ou en impulsion Choisir d’activer ou de désactiver la sécurité positive. La présence d'un bouton de TEST facilite le contrôle total de la centrale, en vérifiant à la fois l'efficacité de la centrale et des sondes connectées. Grâce au format rail DIN/OMEGA à 6 modules, les systèmes peuvent être construits en exploitant la modularité du rail DIN dans les amoires électriques. Outre le signal lumineux d’alarme, il est prévu un buzzer (vibreur) interne Important: Les opérations de montage/entretien de l'appareil doivent être effectuées par un personnel qualifié conformément aux lois et les normes en vigueur. Le constructeur n'assume aucune responsabilité quant à l'utilisation des produits qui doivent se conformer aux normes environnementales. Note importante Avant de brancher l'appareil, il est recommandé de lire attentivement la notice technique et de la conserver pour une utilisation ultérieure. Il est également recommandé d'effectuer correctement les branchements électriques selon les schémas inclus en respectant les consignes de sécurité et les normes. N.B. Consulter la notice technique dans tous les cas où le symbole à côté est présent CONFORMITÉ EN 50194  Notice technique INSTALLER DANS UNE EN 45544-1-3 EN 50270 EN 61010-1 Conforme EN 60079-29-1 Installation EN 60079-29-2 installation/emploi ZONE SÉCURITAIRE NON ATEX Rapport délivré par TUV Italia Guide branchement électrique aussi sur Précautions S’ASSURER de l’intégrité de la centrale après l’avoir retirée de sa confection. Vérifiez que les descriptions sur la boîte soient correspondantes au type de gaz et de la tension électrique utilisée. Suivre attentivement le schéma lorsqu’on effectue le branchement électrique. Nous déclinons toute responsabilité pour des dommages causés à des personnes, animaux ou choses pour n’importe quel usage inapproprié pour laquelle la centrale a été projetée. TERMES ET FIABILITÉ: l’installation de l’unité de controle, son entretien ordinaire et extraordinaire qui doivent s’effectuer une (1) fois par an et la mise au rebut à la fin de la période de fonctionnement garantie par le constructeur ne doivent être effectués que par un personnel autorisé et spécialisé. Pour utiliser avec satisfaction pour une longue période votre centrale numérique, utilisez-la en suivant les précautions : Ne pas mettre en contact avec de l’eau. La centrale n’est pas imperméable et si elle est plongée dans l’eau ou exposée à des taux d’humidité élevée elle peut rapporter de sérieux dommages. Ne pas faire tomber. Des forts coups ou des chutes pendant le transport ou l’installation peuvent endommager l’appareil. Évitez des brusques baisses de température. Des brusques variations de température peuvent provoquer la formation de condense et la centrale pourrait ne pas bien fonctionner. Nettoyage. Ne jamais nettoyer l’appareil avec des produits chimiques. Si nécessaire utilisez un chiffon humide. Caractéristiques Techniques Alimentation Primaire .......................................................................... 110-240 VAC 50/60 Hz ± 10% Alimentation secondaire par batterie Max 2.2 Ah (facutatif) pas fournie..................... 12,7 V ± 10% Charge batterie Max 2.2 Ah ................................................................. contrôlée par microprocesseur Consommation ....................................................................................................... 4 W Max @ 230 V Consommation ................................................................................................... 3 W Max @ 12 V Capacité des contacts sur relais ................................................................................ 10A 250V. résistif Alarmes de gaz Pré alarme commande relais...................................................... fixée à 13% de la L.I.E ou 200 ppm CO Alarme générale commande relais.............................................. fixèe à 20% de la L.I.E ou 300 ppm CO Pannes au capteur détectées par le circuit de défaut .................... interruption, court-circuit ou décadence Contrôle de OVER LOAD (surcharge)...........................................................................................sonde Contrôle de OVER LOAD (surcharge)....................................................................................... batterie Micro interrupteur pour inclure ou exclure les sondes........................................................... 1 incorporé Sonde connectée 1. ............................... Catalytique, Cellule Électrochimique, Pellistor, Semi-conducteur Signal d’entrée .............................................................................................. 4 ÷ 20 mA sur 220 ohm Précision de l’appareil ............................................................................................................. 1% FS Unité de contrôle ........................................................................................... Micro processeur 8 bits Température de fonctionnement ............................................................................... -10 °C ÷ + 60 °C Durée phase d’attente clignotante .................................................................................... 90 secondes Tests manuels .................................................................................................................. incorporés Distance maximum entre les sondes et la centrale...................................................................... 100 m Diamètre des câbles de branchement aux sondes...................................................................... 1 mm2 Branchement: les câbles de connexion de la sonde ne doivent pas être posées ensemble avec ceux de la puissance. Si on pose ensemble les câbles de connexion et ceux de la puissance, il faut utiliser un câble blindé Dimensions rail DIN/Oméga EN 50092 6 modules ................................................................ 105*90*58 Degré de protection ..........................................................................................................En air IP20 Compatibilité Électromagnétique CE ................................................ Normes de référence EN 50270 BX180 Pre Main Alarm Alarm RESET TEST Zone 1 37 mm 45 mm 90 mm 45 mm Power Battery 8 13 20 %LEL  Fault CO GAS 90 mm Over Load Battery Probe 105 mm Page 2 Sondes adaptables par zone et type de gaz So nde CAPTEUR DEGRÉ Apte pour GAZ PLAGE SORTIE PRECIS. ETALONNAGE RELAIS Protect. ZONE Détecté Mesure Automatique SG500 Ca ta ly tiqu e IP30 Domestique CH4-GPL 0÷100% LIE 4÷20 mA ±5 % NON NON SG544 Ca ta ly tiqu e IP44 Tertiaire CH4-GPL 0÷100% LIE 4÷20 mA ±5 % NON NON SGM595 Ca ta ly tiqu e IP55 Tertiaire Voir L is t e Pr ix 0÷100% LIE 4÷20 mA ±5 % OUI NON SGM595/A Ca ta ly tiqu e IP66 Zone 2 Voir L is t e Pr ix 0÷100% LIE 4÷20 mA ±5 % OUI NON SGM533 Ca ta ly tiqu e IP55 Tertiaire Voir L is t e Pr ix 0÷100% LIE 4÷20 mA ±5 % OUI OUI SG800 Ca ta ly tiqu e IP66 Zone 2 Voir L is t e Pr ix 0÷100% LIE 4÷20 mA ±5 % OUI OUI HCF100 Semi-conduct IP55 Tertiaire FREON 0÷300% ppm 4÷20 mA ±5 % NON OUI SG895 Ca ta ly tiqu e ATEX Zone 1 Voir L is t e Pr ix 0÷100% LIE 4÷20 mA ±5 % OUI NON SG580 Ca ta ly tiqu e IP66 Zone 2 Voir L is t e Pr ix 0÷100% LIE 4÷20 mA ±5 % NON NON SGF100 Catalytique IP64 Zone 2 MÉTHANE 0÷100% LIE 4÷20 mA ±5 % OUI OUI SGF102 Catalytique IP64 Zone 2 GPL 0÷100% LIE 4÷20 mA ±5 % OUI OUI SGF104 Optique fluo IP64 Zone 2 Oxy g èn e In % 4÷20 mA ±5 % OUI OUI SGF106 Semi-conduct IP64 Zone 2 FREON 0÷300% ppm 4÷20 mA ±5 % OUI OUI SGF108 Électrochimique IP64 Zone 2 H2S 0÷300% ppm 4÷20 mA ±5 % OUI OUI SGF110 Électrochimique IP64 Zone 2 C O 0÷300% ppm 4÷20 mA ±5 % OUI OUI SGF112 Catalytique IP64 Zone 2 Hyd r ogè n e 0÷100% LIE 4÷20 mA ±5 % OUI OUI CO100r Électrochimique IP55 Tertiaire C O 0÷300% ppm 4÷20 mA ±5 % OUI OUI CO100Ar Electrochimique IP66 Zone 2 C O 0÷300% ppm 4÷20 mA ±5 % OUI OUI SG800duct Ca ta ly tiqu e IP66 Zone 2 CH4-GPL 0÷100% LIE 4÷20 mA ±5 % OUI OUI CO200duct Élect rochimiq ue IP66 Zone 2 C O 0÷300% ppm 4÷20 mA ±5 % OUI OUI Légende Locaux domestiques: Habitations familiales. Chaufferies max 70 kW-h Locaux tertiaires: Grands locaux chaudière, ateliers,…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DTekGaz Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

DTekGaz gas detection central unit monitors toxic and explosive gases across one conventional zone via DIN rail mounting. Delivers dual alarms at 8% LEL (120 ppm) and 13% LEL (200 ppm) with integrated fault detection for probe integrity, suitable for industrial safety systems requiring single-probe gas monitoring.

Frequently Asked Questions

What is the DTekGaz BX180 gas detection central unit used for?

The DTekGaz BX180 central unit monitors toxic and explosive gas leaks in industrial environments, domestic settings, and small underground car parks. It connects one remote probe to detect gas presence and provides dual alarms at 8% LEL (120 ppm) and 13% LEL (200 ppm) with a general alarm at 20% LEL (300 ppm).

What are the specifications of the DTekGaz 3G-CBM-02006 gas detection central unit?

The DTekGaz 3G-CBM-02006 is a DIN-rail-mounted gas detection central unit with one conventional zone for one probe. It features alarm thresholds at 8% LEL (120 ppm), 13% LEL (200 ppm), and 20% LEL (300 ppm). It includes fault detection for probe interruption, short-circuit, and degradation, and supports toxic and/or explosive gas types.

Where to buy the DTekGaz BX180 gas detection central unit in Singapore?

You can source the DTekGaz BX180 gas detection central unit from 3G Electric in Singapore. We supply this industrial safety device and handle logistics, customs clearance, and delivery to your facility. Contact us for availability and lead time on this DTekGaz model.

How to install the DTekGaz BX180 gas detection central unit?

Installation must be performed by qualified personnel following local regulations and the manufacturer's technical manual. Mount the unit on a DIN rail in a non-ATEX safe zone, connect the remote probe per the wiring diagram, and configure DIP switches for gas type and relay mode. Always read the manual before powering the device.

Used in

Common applications for DTekGaz
Petrochemical plants — DTekGaz ATEX SG895 catalytic sensor probes monitor explosive gas concentrations in confined tanks and process vessels
Refrigeration and HVAC maintenance — DTekGaz HCF100 semiconductor probe detects R407C, R410A, and R32 leaks during service and commissioning
Industrial hazardous areas — DTekGaz extension card relay outputs interface with plant PLC/DCS systems to trigger alarms and emergency shutdowns
Portable field detection — DTekGaz 12 V rechargeable battery and metal-housed hydrogen/butane probes support temporary site surveys and confined-space entry
Fixed control room installations — DTekGaz 24 VDC audible alarm and extension modules provide centralized monitoring of multiple distributed sensor probes
Water treatment and biogas plants — DTekGaz catalytic and semiconductor probes detect methane, hydrogen sulfide, and other hazardous gas byproducts

DTekGaz Products

3G Electric supplies DTekGaz gas detection. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Gas detection central unit Din rail 2 probes
DTekGaz
Gas detection central unit Din rail 2 probes
Detection unit 1 probe
DTekGaz
Detection unit 1 probe
DTekGaz
DTekGaz
Gas detection central rail DIN 16 probes - 12V
DTekGaz
DTekGaz
Gas detection center Din rail 4 probes
DTekGaz
DTekGaz
Gas detection center Din rail 8 probes - 12V
Detection unit 3 probes
DTekGaz
Detection unit 3 probes

More from DTekGaz

View all DTekGaz parts
"Natural Gas Detection Test Kit" case (with TS1008+printer)
DTekGaz
"Natural Gas Detection Test Kit" case (with TS1008+printer)
DTekGaz
DTekGaz
R134A gas probe
DTekGaz
DTekGaz
Battery 12V - 2.2Ah
DTekGaz
DTekGaz
CO2 probe metal housing IP66
DTekGaz
DTekGaz
Probe for R32 gas
DTekGaz
DTekGaz
Probe for R404 gas
DTekGaz
DTekGaz
Central detection box DIN rail small IP 65
DTekGaz
DTekGaz
Valve for 1liter bottle