Dwyer 629-05-CH-P2-E5-S1-3V transmitter
Dwyer differential pressure transmitter (629-05-CH-P2-E5-S1-3V) measures pressure differentials to 100 psid with 0.5% accuracy and 4-20 mA output. IP65-rated with 1/4" NPT female connection, suitable for HVAC and…
SKU 3G-CBM-02140
Also listed as: DWY 06016 · DWY-06016
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
Dwyer differential pressure transmitter (629-05-CH-P2-E5-S1-3V) measures pressure differentials to 100 psid with 0.5% accuracy and 4-20 mA output. IP65-rated with 1/4" NPT female connection, suitable for HVAC and process control applications.
Frequently Asked Questions
What is the Dwyer 629-05-CH-P2-E5-S1-3V transmitter used for?
The Dwyer 629-05-CH-P2-E5-S1-3V differential pressure transmitter monitors pressure differences in air, gas, and compatible liquids. It is suitable for HVAC, heat exchangers, filters, pumps, and process control applications where 0.5% accuracy and a 4-20 mA output are required.
What are the specifications of the Dwyer 629-05-CH-P2-E5-S1-3V?
The Dwyer 629-05-CH-P2-E5-S1-3V measures 0-100 psid with 0.5% accuracy and a 4-20 mA output. It has an IP65 enclosure, 1/4" NPT female process connection, CE certification, burst pressure of 500 psi, and overpressure rating of 200 psi. Operating temperature range is -18 to +93°C.
Where to buy the Dwyer 629-05-CH-P2-E5-S1-3V in Singapore?
3G Electric supplies the Dwyer 629-05-CH-P2-E5-S1-3V differential pressure transmitter to Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this model.
How to install the Dwyer 629-05-CH-P2-E5-S1-3V transmitter?
Mount the Dwyer 629-05-CH-P2-E5-S1-3V in any orientation using the 1/4" NPT female connections. Use compatible liquids or gases within 0-100 psid. Wire the 4-20 mA loop to the terminal block; ensure supply voltage is 13-30 VDC. Zero and span adjustments are accessible under the top cover.
Used in