Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
DwyerMeasurement

Dwyer Air velocity probe AVU 4M/S 0/10V AVU-1-V

The Dwyer AVU air velocity probe measures air and non-combustible gas flow with 0/10V analog output and ±5% accuracy, housed in an IP67-rated enclosure suitable for industrial HVAC and process monitoring applications.

SKU 3G-CBM-02144

Also listed as: DWY 08008 · DWY-08008

Brand
Dwyer
Item
Air velocity probe AVU 4M/S 0/10V AVU-1-V
Category
Measurement
UNSPSC
41112412 — Pressure gauge
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Dwyer
fluid
Air and non-combustible compatible gases
output
0/10V
accuracy
±5%
ce certified
true
housing rating
IP67
max startup current
85 mA

Datasheet Content

Série AVU Sonde de vitesse de l’air Série AVU Idéal pour mesure CVC, ±5% ou ±8% avec précision sur toute la gamme 3-11/32 3/4 [19.0] [85.0] 51/64 [2.0] 8-55/64 [225.0] 9-29/64 [240.0] 2-1/4 [57.0] La sonde de vitesse de l’air Série AVU est idéale pour un large éventail d’applications SPÉCIFICATIONS de mesures de CVC et de contrôle, en particulier dans les systèmes intégrés de domotique et Fluides : Air et gaz compatibles non combustibles. DE GESTION DE LÏNERGIE ,A SÏRIE !65 OFFRE UNE ÏTONNANTE PRÏCISION DE  Ì BAS COßT AVEC Précision : ±5% et ±8%. modèles dont les plages de mesures vont de 0-4 à 0-16 m/s, fournissant un signal de sortie Temps de réponse (90%) :  SEC TYPIQUE  de 4-20 mA ou 0-10 VCC. Limites de température : 0 à +50°C. ,A SONDE 3ÏRIE !65 MESURE LA PERTE DE CHALEUR DUN DE SES DEUX ÏLÏMENTS DE DÏTECTION DANS Limite d’humidité : 0-90% HR, sans condensation. LE COURANT DAIR POUR CALCULER LA VITESSE DE LAIR ,ES APPAREILS SONT PRATIQUEMENT INSENSIBLES Alimentation : à la dérive due à l’élément de détection, ce qui assure leur précision sur toute la plage de - Modèles A : 24 VCC +10% -15% ; VITESSE DE L’AIR vitesse de l’air. - Modèles V : 24 VCC ou 24 VCA +10% - 15%. s 3ORTIE   M! OU   6## Signal de sortie : modèles –A : boucle de courant 4-20 mA ; modèles -V : 0-10 VCC. s "OÔTIER )0 Résistance de boucle : MODÒLES !  OHMS s !LIMENTATION EN COURANT CONTINU OU ALTERNATIF VERSION EN BOUCLE  ## SEULEMENT Consommation électrique : 60 mA + courant de sortie. s 0RÏCISION  ET  Courant de démarrage maximal : 85 mA ; 10 Limite de Courant de V. Output :  -ODÒLES DE 6  M! APPLICATIONS Connexions électriques : #ONNECTEUR Ì VIS 0RESSE ÏTOUPE POUR lL DE   MM lL DE   s !PPROVISIONNEMENT ET GAINE DE VENTILATEUR DEXTRACTION Boîtier : IP67 sauf point de mesure. s 3YSTÒMES DE SALLE BLANCHE Dimensions de la sonde : 19 mm x 240 mm. s ³TUDES ET FABRICATION DE SYSTÒMES CONTRE LA POLLUTION ATMOSPHÏRIQUE Orientation : )NDIFFÏRENTE ,A SONDE DOIT ÐTRE ALIGNÏE AVEC LE mUX DAIR s 3YSTÒMES DE CONTRÙLE DE PROCESSUS Poids : 250 g. Homologation : CE. Modèle Gamme Sortie Précision Réf. AVU-1-A  TO  FPM  TO  MS 4 to 20 mA 5% $79 AVU-2-A  TO  FPM  TO  MS 4 to 20 mA 5% $79 AVU-3-A  TO  FPM  TO  MS 4 to 20 mA 5% $79 AVU-1-V  TO  FPM  TO  MS 0 to 10 VDC 5% $79 AVU-2-V  TO  FPM  TO  MS 0 to 10 VDC 5% $79 AVU-3-V  TO  FPM  TO  MS 0 to 10 VDC 5% $79 AVUB-1-V  TO  FPM  TO  MS 0 to 10 VDC 8% $79 AVUB-2-V  TO  FPM  TO  MS 0 to 10 VDC 8% $79 AVUB-3-V  TO  FPM  TO  MS 0 to 10 VDC 8% $79

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Dwyer AVU air velocity probe measures air and non-combustible gas flow with 0/10V analog output and ±5% accuracy, housed in an IP67-rated enclosure suitable for industrial HVAC and process monitoring applications.

Frequently Asked Questions

What is the Dwyer AVU air velocity probe used for?

The Dwyer AVU air velocity probe measures air and non-combustible gas flow in HVAC systems, building automation, clean rooms, and process control. It provides a 0/10 VDC analog output with ±5% accuracy and is housed in an IP67-rated enclosure for industrial environments.

What are the specifications of the Dwyer AVU-1-V?

The Dwyer AVU-1-V measures 0 to 4 m/s air velocity with 0/10 VDC output and ±5% accuracy. It operates on 24 VDC or 24 VAC power, has a maximum startup current of 85 mA, and is CE certified. The probe dimensions are 19 mm x 240 mm with an IP67-rated housing.

Where to buy the Dwyer AVU-1-V in Singapore?

3G Electric supplies the Dwyer AVU-1-V air velocity probe to Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact our team for a quote and lead time on this measurement instrument.

How to install the Dwyer AVU air velocity probe?

Install the Dwyer AVU probe aligned with the airflow direction; orientation is otherwise indifferent. Use the cable gland for 4-8 mm diameter cable and connect to the screw terminals. Ensure the power supply meets 24 VDC or 24 VAC requirements and avoid condensation above 90% RH.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer measurement. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dwyer
Dwyer
Air velocity probe AVU 4M/S 0/10V 8% AVUB-1-V
Dwyer
Dwyer
AVU air velocity probe 8M/S 0/10V AVU-2-V
Dwyer
Dwyer
AVU air velocity probe 16M/S 0/10V AVU-3-V
Dwyer
Dwyer
Air speed probe AVU 8M/S 4/20mA AVU-2-A
Dwyer
Dwyer
Air velocity probe AVU 16M/S 4/20mA AVU-3-A
Dwyer
Dwyer
AVU air speed probe 4M/S 4/20mA AVU-1-A

More from Dwyer

View all Dwyer parts
Magnehelic pressure gauge 2000-30PA
Dwyer
Magnehelic pressure gauge 2000-30PA
Flow meter FS 2
Dwyer
Flow meter FS 2
Dwyer
Dwyer
Average flow probe PAFS-1002
Dwyer
Dwyer
MAFS-48 metallic average flow probe
Dwyer
Dwyer
Transmitter 645-6
Dwyer
Dwyer
Current detector SCS-211125-R
Dwyer
Dwyer
Current transmitter SCT10-102
Dwyer
Dwyer
Current transmitter CCT 50-203