Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Dwyer Average flow probe PAFS-1004 - Measurement
DwyerMeasurement

Dwyer Average flow probe PAFS-1004

The Dwyer PAFS-1004 is an average flow probe designed for fluid measurement in industrial piping systems. It features ABS/polycarbonate construction rated UL94-5V and connects via 6 mm ID tubing. Operating range…

SKU 3G-CBM-02226

Also listed as: DWY 30006 · DWY-30006

Brand
Dwyer
Item
Average flow probe PAFS-1004
Category
Measurement
UNSPSC
41112412 — Pressure gauge
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Dwyer
material
ABS/polycarbonate UL94-5V
mounting
Integral bracket with gasket
length cm
19.55
probe type
Average flow probe
tubing connection
6 mm ID, 10 mm OD
storage temperature range
-40 to +60°C
operating temperature range
4 to 49°C

Datasheet Content

Sonde de débit moyen Idéal pour la mesure de débit de ventilation La Série PAFS-1000 Sonde de Debit Moyen est indiquée pour détecter une pression différentielle dans la section d’entiée d’unités terminales a volume d’cit variable et d’unités terminales de ventilation. Les appareils peuvent également étre utilisés pour détecter la pression différentielle en d‘autres endroits des systémes de conduite principaux et secondaires. Le port “H” détecte la pression totale tandis que le port “L” détecte la pression statique. La différence entre ces signaux correspond au différentiel, ou pression dynamique. Pour les modéles de PAFS-1002 @ PAFS-1005, jusqu’d quatte points de détection et des longueurs de 8.02 4 25.26 cm sont disponibles pour adapter le diamtre de Ia boite de 10.16 € 40.64 cm. Pour les modéles de PAFS:1006 a PAFS -1011, jusqu’t dix points de détection et des longueurs de 31.75 & 60.72 cm sont disponibles pour adapter les dimensions de conduite Gi une taille adéquate, SPECIFICATIONS Service : Air et gaz compatible. Matériaux : ABS/polycarbonate (UL94-5V). Limites de Température : Opérationnelle : de 4 4 49°C ; Stockage : de -40 4 +60°C. Raccord : 6 mm ID, 10 mm OD de tubage. Position de Montage : Bride intégrale avec joint. Poids : 28 g. MOUNTING HOLES 2X03/16 [04.76] PUSH-ON CONNECTIONS: Bp FOR 3/8 POLY TUBING [9.53 OD] 3/4 mae FOAM GASKET 1/8 THK [6.35 THK] 3178] APPLICATIONS Contidle de zone dans les systémes HVAC. Modeéle Longueur (Dimension A) Ref. PAFS-1002 | 8.02 cm WwY30002 PAFS-1003 | 13.73 cm WY30004 PAFS-1004 | 19.55 cm WY30006 PAFS-1005 | 25.26 cm WwY30008 PAFS-1006 | 31.75 cm WY30010 PAFS-1007 | 37.47 cm WY30012 PAFS-1008 | 43.50 cm WwY30014 PAFS-1009 | 49.29 cm WY30016 PAFS-1010 | 55.0] cm WY30018 PAFS-1011 | 60.72 cm wy30020 Dwyer

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Dwyer PAFS-1004 is an average flow probe designed for fluid measurement in industrial piping systems. It features ABS/polycarbonate construction rated UL94-5V and connects via 6 mm ID tubing. Operating range spans 4 to 49°C, making it suitable for HVAC and process monitoring applications.

Frequently Asked Questions

What is the Dwyer PAFS-1004 average flow probe used for?

The Dwyer PAFS-1004 average flow probe measures differential pressure in HVAC and process monitoring systems. It detects total and static pressure in variable-air-volume terminal units and ductwork, helping engineers balance airflow and monitor ventilation performance in commercial and industrial buildings.

What are the specifications of the Dwyer PAFS-1004?

The Dwyer PAFS-1004 has an ABS/polycarbonate body rated UL94-5V, a 19.55 cm probe length, and connects via 6 mm ID, 10 mm OD tubing. It operates from 4 to 49°C and stores from -40 to +60°C. The integral bracket with foam gasket simplifies mounting on ductwork.

Where to buy the Dwyer PAFS-1004 in Singapore?

3G Electric supplies the Dwyer PAFS-1004 average flow probe to Singapore. We handle sourcing, logistics, customs clearance, and local delivery. Contact our team for pricing and lead time on this measurement device for HVAC and process applications.

How to install the Dwyer PAFS-1004 average flow probe?

Mount the Dwyer PAFS-1004 using its integral bracket and foam gasket to seal against the duct. Connect 6 mm ID tubing to the push-on ports: the 'H' port for total pressure and the 'L' port for static pressure. Ensure the probe is perpendicular to airflow for accurate differential pressure readings.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer measurement. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Dwyer
Dwyer
Average flow probe PAFS-1003
Dwyer
Dwyer
Average flow probe PAFS-1005
Dwyer
Dwyer
Average flow probe PAFS-1007
Dwyer
Dwyer
Average flow probe PAFS-1008
Dwyer
Dwyer
Average flow probe PAFS-1010
Average flow rate probe PAFS-1006
Dwyer
Average flow rate probe PAFS-1006

More from Dwyer

View all Dwyer parts
Magnehelic pressure gauge 2000-30PA
Dwyer
Magnehelic pressure gauge 2000-30PA
Flow meter FS 2
Dwyer
Flow meter FS 2
Dwyer
Dwyer
Average flow probe PAFS-1002
Dwyer
Dwyer
MAFS-48 metallic average flow probe
Dwyer
Dwyer
Transmitter 645-6
Dwyer
Dwyer
Current detector SCS-211125-R
Dwyer
Dwyer
Current transmitter SCT10-102
Dwyer
Dwyer
Current transmitter CCT 50-203