Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Dwyer Water leak detector WD3-LP-D2-A - Measurement
DwyerMeasurement

Dwyer Water leak detector WD3-LP-D2-A

Dwyer water leak detector for conductive fluids with 24 VDC/24 VAC operation and 85 dB audible alarm. Detects leaks at 1/32 inch sensitivity across 0 to +50°C. SPDT relay output suits facility monitoring and…

SKU 3G-CBM-02339

Also listed as: DWY 56006 · DWY-56006

Brand
Dwyer
Item
Water leak detector WD3-LP-D2-A
Category
Measurement
UNSPSC
41112412 — Pressure gauge
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Dwyer
service
water or conductive fluids
voltage
24 VDC / 24 VAC
relay type
SPDT
audible alarm
85 dB @ 30 cm
temperature range
0 to +50°C
detection sensitivity
1/32 inch

Datasheet Content

Détecteur de fuite d’eau Série WD3 Alimentation 24 Volts ou sur batteries, Relais SPST ou SPDT 3-5/8 1-3/16 [91.70] [30.12] 3 [76.68] 5/16 [7.52] 1-5/16 [33.15] 5/8 [16.58] 4-1/8 [105.23] 2 1/8 [50.66] [2.50] 5/8 [16.18] La Série WD3 Détecteur de Fuite d’Eau protège l’équipement de tout dégât des SPÉCIFICATIONS eaux en détectant la présence d’eau dans les récipients de récupération d’eau de l’appareil Service : Eau ou Fluides conducteurs de traitement, sous les faux-planchers du centre de données, ou sur les planchers autour Ecart de Détection Minimum : 1/32”. des pompes de puisards et des drains. L’eau est détectée une fois le niveau atteint qui lie Type de Commutateur : Modèles de Batterie : SPST NON SSR ; les deux bandes conductrices sur le fond du boîtier. En fonction du modèle commandé, une Modèles de Source Externe d’Alimentation : Relais SPDT. alerte audible ou visuelle fournit une indication locale de l’état de l’alarme et un commutateur Caractéristiques Electrique : Modèle de Batterie : Pilot facteur de service interne donnera une indication ou un contrôle à distance pour prévenir une accumulation 250 mA @ 24 VDC ; Modèles de Source Externe d’Alimentation : 1A @ 24 VAC/DC. d’eau. Alarme Audible : Au moins 85 dB @ 30 cm (dépend du modèle). Pour les applications où l’alimentation n’est pas disponible, le modèle WD3-BP-D1-A est Alarme Visuelle : LED rouge pour niveau d’eau ; LED jaune pour batterie faible (modèles alimenté par batterie. Le détecteur d’eau peut être alimenté en tension alternative ou alimentés par batterie seulement) ; LED verte le niveau de puissance (modèles alimentés en continue. La hauteur de détection peut être réglée à son plus bas à 1/32” à l’aide du support source externe seulement). de fixation réglable inclus. Ce support de fixation peut s’attacher à n’importe quelle surface Limites de Température : 0 to +50°C. plane à l’aide de bandes adhésives d’attache ou de vis de fixation. Besoins en Puissance : Modèle de Batterie : 3V CR2450 batterie au lithium métal, installée à son emplacement, remplaçable par l’utilisateur ; ACCESSOIRE Modèles de Source Externe d’Alimentation : de 11 à 27 VAC/DC. A-WD3-BRK, Support de Fixation de Remplacement. Consommation électrique : Modèle de Batterie : 0.9 mA en état de stabilité / 3.0 mA pendant l’état d’alarme ; Modèles de Source Externe d’Alimentation : 30 mA en état de stabilité / 85 mA pendant l’état d’alarme. Modèle Sortie Puissance Alarme Réf. Durée de Vie de la Batterie : 5 ans en état de stabilité / 48 heures en état d’alarme. Audible Raccordement Electrique : 1.5 m, 22 AWG, PVC, câble classé UL plenum. WD3-BP-D1-A SPST NON SSR Batterie Oui DWY56002 Matériaux du Boîtier : ABS et polycarbonate avec un classement d’inflammabilité UL 94 V-0. WD3-LP-D2 Relais SPDT 11 à 27 VAC/DC Non DWY56004 Caractéristiques du Boîtier : Modèles audibles d’alarme : Hermétique jusqu’au WD3-LP-D2-A Relais SPDT 11 à 27 VAC/DC Oui 3G-CBM-02339 3/4 de la hauteur du boîtier ; Modèles non-audibles d’alarme : IP 68 submersible. Poids : 137.5 g. Homologations : CE, RoHS. RoHS

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Dwyer water leak detector for conductive fluids with 24 VDC/24 VAC operation and 85 dB audible alarm. Detects leaks at 1/32 inch sensitivity across 0 to +50°C. SPDT relay output suits facility monitoring and equipment protection applications.

Frequently Asked Questions

What is the Dwyer WD3-LP-D2-A water leak detector used for?

The Dwyer WD3-LP-D2-A detects water or conductive fluid leaks to protect equipment in data center subfloors, treatment water recovery vessels, and around sump pumps and drains. It triggers an 85 dB audible alarm and SPDT relay output for remote monitoring, making it suitable for facility monitoring and equipment protection applications.

What are the specifications of the Dwyer WD3-LP-D2-A?

The Dwyer WD3-LP-D2-A operates on 24 VDC/24 VAC, detects leaks at 1/32 inch sensitivity, and has an SPDT relay rated 1A @ 24 VAC/DC. Its audible alarm is 85 dB at 30 cm, and the temperature range is 0 to +50°C. It is designed for water or conductive fluids.

Where to buy the Dwyer WD3-LP-D2-A in Singapore?

3G Electric supplies the Dwyer WD3-LP-D2-A water leak detector to Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this Dwyer model. Our team provides technical support for installation and application questions.

How to install the Dwyer WD3-LP-D2-A water leak detector?

Mount the Dwyer WD3-LP-D2-A using the included adjustable bracket on any flat surface with adhesive strips or screws. Position it so the conductive strips on the bottom contact water at the desired 1/32 inch detection height. Connect 24 VDC/24 VAC power and wire the SPDT relay for remote alarm or control.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer measurement. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Related products

More from Dwyer

View all Dwyer parts
Magnehelic pressure gauge 2000-30PA
Dwyer
Magnehelic pressure gauge 2000-30PA
Flow meter FS 2
Dwyer
Flow meter FS 2
Dwyer
Dwyer
Average flow probe PAFS-1002
Dwyer
Dwyer
MAFS-48 metallic average flow probe
Dwyer
Dwyer
Transmitter 645-6
Dwyer
Dwyer
Current detector SCS-211125-R
Dwyer
Dwyer
Current transmitter SCT10-102
Dwyer
Dwyer
Current transmitter CCT 50-203