Fantini Cosmi Built-in hygrostat 1 outlet L22EM1A 230V
Fantini Cosmi flush-mount hygrostat with single-pole relay output for humidity control in HVAC and building automation. Measures 0-100 RH% with ±0.7 RH% accuracy at 230 Vac, IP55 protected. Ideal for wall-mounted…
SKU 3G-CBM-03658
Also listed as: FAN 24048 · FAN-24048
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
Fantini Cosmi flush-mount hygrostat with single-pole relay output for humidity control in HVAC and building automation. Measures 0-100 RH% with ±0.7 RH% accuracy at 230 Vac, IP55 protected. Ideal for wall-mounted indoor humidity management applications.
Frequently Asked Questions
What is the Fantini Cosmi L22EM1A hygrostat used for?
The Fantini Cosmi L22EM1A is a flush-mount hygrostat used for humidity control in HVAC and building automation systems. It measures 0-100 RH% with ±0.7 RH% accuracy and operates a single-pole relay output at 230 Vac for dehumidification or humidification applications.
What are the specifications of the Fantini Cosmi L22EM1A?
The L22EM1A is a flush-mount hygrostat with one outlet, single-pole relay output rated 16(4)A 240 Vac, power supply 230 Vac, measuring range 0-100 RH%, accuracy ±0.7 RH%, and IP55 protection. It complies with EN60730-1 and EN60730-2-9.
Where to buy the Fantini Cosmi L22EM1A in Singapore?
You can source the Fantini Cosmi L22EM1A hygrostat through 3G Electric in Singapore. We supply this flush-mount hygrostat for humidity control and handle logistics, customs clearance, and delivery to your facility.
How to install the Fantini Cosmi L22EM1A hygrostat?
Install the L22EM1A by flush mounting it in a panel using the provided fixing brackets. Ensure the sealing gasket is fitted to maintain IP55 protection. Connect the 230 Vac supply and single-pole relay output per the wiring diagram. Set the desired humidity setpoint and hysteresis for ON/OFF or PID control.
Used in
Common applications for Fantini CosmiFantini Cosmi Products
3G Electric supplies Fantini Cosmi switches & thermostats. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.