Kromschroder Gas filter GFK 20R10/6
The Kromschroder GFK 20R10/6 is a gas filter for burner control systems with DN20 sizing and Rp ¾ connection. It features a polypropylene foam element rated to 50 µm and handles maximum pressure of 0.4 bar, suitable…
SKU 3G-CBM-04440
Also listed as: KRO 02104 · KRO-02104
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
The Kromschroder GFK 20R10/6 is a gas filter for burner control systems with DN20 sizing and Rp ¾ connection. It features a polypropylene foam element rated to 50 µm and handles maximum pressure of 0.4 bar, suitable for fuel gas applications requiring DIN 3386 compliance.
Frequently Asked Questions
What is the Kromschroder GFK 20R10/6 gas filter used for?
The Kromschroder GFK 20R10/6 is used to filter fuel gas and combustion air in burner control systems, protecting downstream devices from blockage. It is suitable for natural gas, town gas, LPG (gaseous), biogas, and air, and complies with DIN 3386.
What are the specifications of the Kromschroder GFK 20R10/6?
The Kromschroder GFK 20R10/6 has a DN20 sizing with Rp ¾ threaded connection per ISO 7-1. It uses a polypropylene foam filter element rated to 50 µm, handles a maximum inlet pressure of 0.4 bar, and operates from -15 °C to +80 °C. The housing is made of AlSi.
Where to buy the Kromschroder GFK 20R10/6 in Singapore?
3G Electric supplies the Kromschroder GFK 20R10/6 gas filter to customers in Singapore. We handle logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this DN20 burner control component.
How to install the Kromschroder GFK 20R10/6 gas filter?
Install the Kromschroder GFK 20R10/6 with the flow direction arrow pointing downstream. Use the Rp ¾ threaded connections per ISO 7-1. Ensure the filter element is clean before installation. For pressure measurement, use the Rp 1/8 test points on the inlet side. Follow local gas safety regulations.
Used in
Common applications for KromschroderKromschroder Products
3G Electric supplies Kromschroder burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.