Satronic DKG 972-N mod.10 is a burner control relay for 2-stage atmospheric gas burners, operating at 50 Hz ±5% or 60 Hz ±5% with selectable flame detection via ionization probe, infrared, or UV sensors. Supply…

SKU 3G-CBM-05924

Also listed as: 972 N · 972-N

Brand
Satronic
Item
Relay DKG 972-N mod.10
Part Number
972N
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Satronic
Manufacturer Part Number
972N
burner type
2-stage atmospheric gas burners
frequency option 1
50 Hz ±5%
frequency option 2
60 Hz ±5%
flame detector options
ionization probe, IRD 1020 infrared, UVD 971 UV
supply voltage option 1
220/240V -15…+10%
supply voltage option 2
110/120V -15…+10%
probe insulation min mohm
50
probe leakage max microamps
0.4

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Satronic Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

Satronic DKG 972-N mod.10 is a burner control relay for 2-stage atmospheric gas burners, operating at 50 Hz ±5% or 60 Hz ±5% with selectable flame detection via ionization probe, infrared, or UV sensors. Supply voltage options include 220/240V or 110/120V. Probe insulation minimum 50 MΩ ensures reliable performance in industrial heating applications.

Frequently Asked Questions

What is the Satronic DKG 972-N mod.10 used for?

The Satronic DKG 972-N mod.10 is a burner control relay designed for 2-stage atmospheric gas burners. It is commonly used in industrial heating applications and hot air generators (WLE per DIN 4794) to control and monitor burner operation with selectable flame detection via ionization probe, infrared, or UV sensors.

What are the specifications of the Satronic DKG 972-N mod.10?

The Satronic DKG 972-N mod.10 operates at 50 Hz ±5% or 60 Hz ±5% with supply voltage options of 220/240V -15…+10% or 110/120V -15…+10%. It supports flame detection via ionization probe, IRD 1020 infrared, or UVD 971 UV sensors. Probe insulation is minimum 50 MΩ, and probe leakage is maximum 0.4 µA.

Where to buy the Satronic DKG 972-N mod.10 in Singapore?

You can source the Satronic DKG 972-N mod.10 through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for availability and lead time on this Honeywell-compatible burner control relay.

How to install the Satronic DKG 972-N mod.10?

Installation should follow the manufacturer's datasheet and local regulations. Ensure the supply voltage matches the unit (220/240V or 110/120V) and frequency (50/60 Hz). Connect the flame detector (ionization probe, IRD 1020, or UVD 971) with probe insulation above 50 MΩ. Use a fast 10 A or time-delay 6 A fuse as specified.

Used in

Common applications for Satronic
Industrial boiler systems — Satronic TF 836.3 relay for oil burner control up to 30 kg/h
Commercial heating plants — Satronic DMG 972-N MOD.01 for flame detection in gas burners
Process heating equipment — Satronic CM391.2 10.10 for automatic gas burner safety lock-out
Forced draught oil burners — Satronic DKO 970-N mod.05 for 1 or 2-speed intermittent operation
Forced draught gas burners — Satronic SR3/TR2V SF for burners up to 120 kW
Atmospheric gas burners — Satronic SM 592.2 TW1.5/TS10 for intermittent operation with manual reset
Not sure this is the right part? Photo-identify it

Satronic Products

3G Electric supplies Satronic burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Relay DKG 972-N mod.05
Satronic
Relay DKG 972-N mod.05
Relay DKG 972-N mod.28
Satronic
Relay DKG 972-N mod.28
DKG 972-N relay mod.03
Satronic
DKG 972-N relay mod.03
Relay DLG 976-N MOD.01
Satronic
Relay DLG 976-N MOD.01
Relay DMG 970-N MOD.01
Satronic
Relay DMG 970-N MOD.01
Relay DMG 973-N MOD.01
Satronic
Relay DMG 973-N MOD.01

More from Satronic

View all Satronic parts
Cell FC13R (replaced by FT13-V)
Satronic
Cell FC13R (replaced by FT13-V)
Relay DLG 976-N MOD.03
Satronic
Relay DLG 976-N MOD.03
QRA 10MC cell
Satronic
QRA 10MC cell
Cell FC11 (replaced by FT11-V)
Satronic
Cell FC11 (replaced by FT11-V)
Cell QRA 10C
Satronic
Cell QRA 10C
Cell QRA 55 E 27
Satronic
Cell QRA 55 E 27
Relay 530 SE
Satronic
Relay 530 SE
Cell MZ 770S
Satronic
Cell MZ 770S

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first