Satronic Relay SM 592.2 TW5/TS10
The Satronic Relay SM 592.2 TW5/TS10 is a burner control relay rated for maximum burner outputs of 120 kW per prEN 676 or 350 kW per DIN 4788, featuring fast-blow fuse protection ≤5A and minimum insulation resistance…
SKU 3G-CBM-06018
Local availability & support — Singapore
- Local office
- 20 Woodlands Link #09-05, Singapore 738733
- Phone
- +65 8878 8355
- Delivery
- Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
- Payment
- Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
- Ships to
- Singapore
Need installation or engineering help?
Ask a question
Product Description
The Satronic Relay SM 592.2 TW5/TS10 is a burner control relay rated for maximum burner outputs of 120 kW per prEN 676 or 350 kW per DIN 4788, featuring fast-blow fuse protection ≤5A and minimum insulation resistance ≥50 MΩ for industrial combustion applications.
Frequently Asked Questions
What is the Satronic Relay SM 592.2 TW5/TS10 used for?
The Satronic Relay SM 592.2 TW5/TS10 is an automatic gas burner control system designed for atmospheric and fan-assisted burners in intermittent operation. It is suitable for combi boilers, heating boilers, warm air generators, radiant heaters, water heaters, ovens, and cookers.
What are the specifications of the Satronic Relay SM 592.2 TW5/TS10?
The Satronic Relay SM 592.2 TW5/TS10 has a maximum burner output of 120 kW per prEN 676 or 350 kW per DIN 4788. It features fast-blow fuse protection ≤5A, minimum insulation resistance ≥50 MΩ, maximum parasitic capacitance ≤1 nF, and maximum short-circuit current <200 µA AC.
Where to buy the Satronic Relay SM 592.2 TW5/TS10 in Singapore?
3G Electric supplies the Satronic Relay SM 592.2 TW5/TS10 to customers in Singapore. We handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this burner control relay.
How to install the Satronic Relay SM 592.2 TW5/TS10?
Installation of the Satronic Relay SM 592.2 TW5/TS10 should follow the manufacturer's datasheet and local regulations. Ensure the relay is mounted in a suitable enclosure, wired per the diagram, and that the ionization probe is correctly positioned for flame monitoring. Manual reset is required after lock-out.
Used in
Common applications for SatronicSatronic Products
3G Electric supplies Satronic burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.