Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

CHAINFLEX Control Cable: 16 AWG, 36 Conductors, Order by the Foot, PVC Jacket - Continuous Flexing Control Cables
CHAINFLEXContinuous Flexing Control Cables

CHAINFLEX Control Cable: 16 AWG, 36 Conductors, Order by the Foot, PVC Jacket

The CHAINFLEX Control Cable: 16 AWG is a continuous flexing control cable from the CF6 series, featuring 36 copper conductors with a PVC jacket rated at 300 V. It includes a ground conductor and is UV/sunlight…

SKU 3G-OTH-50870

Brand
CHAINFLEX
Item
Control Cable: 16 AWG, 36 Conductors, Order by the Foot, PVC Jacket
Category
Continuous Flexing Control Cables
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

CHAINFLEX
Manufacturer Part Number
CF6-15-36
Type
Order by the Foot, PVC Jacket, 300 V
Standards
IEC 60332-1-2
Conductors
36
Cable Series
CF6
Product Type
Control Cable
Includes Ground
Yes
Conductor Material
Copper
Resistance Properties
UV/Sunlight Resistant
Minimum Bend Radius Factor - Fixed
4 x OD
Minimum Bend Radius Factor - E-Chain
6.8 x OD
Minimum Bend Radius Factor - Flexible
5 x OD
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CHAINFLEX Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The CHAINFLEX Control Cable: 16 AWG is a continuous flexing control cable from the CF6 series, featuring 36 copper conductors with a PVC jacket rated at 300 V. It includes a ground conductor and is UV/sunlight resistant, with minimum bend radius factors of 4 x OD for fixed, 5 x OD for flexible, and 6.8 x OD for e-chain applications. This cable complies with IEC 60332-1-2 standards and is sold by the foot.

Frequently Asked Questions

What is CHAINFLEX Control Cable CF6-15-36 used for?

CHAINFLEX Control Cable CF6-15-36 is a continuous flexing control cable designed for automated machinery, robotics, and cable carrier (e-chain) systems. Its 36 copper conductors and UV-resistant PVC jacket suit industrial environments requiring repeated bending and exposure to sunlight.

What are the specifications of CHAINFLEX Control Cable CF6-15-36?

This CHAINFLEX CF6 series cable has 36 conductors of 16 AWG copper, a PVC jacket rated at 300 V, and includes a ground conductor. Minimum bend radius factors are 4 x OD fixed, 5 x OD flexible, and 6.8 x OD for e-chain. It complies with IEC 60332-1-2 and is UV/sunlight resistant.

Where to buy CHAINFLEX Control Cable CF6-15-36 worldwide?

3G Electric supplies CHAINFLEX Control Cable CF6-15-36 worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.

How to select the right CHAINFLEX control cable for e-chain applications?

For e-chain applications, ensure the cable's minimum bend radius factor matches your carrier's requirements. The CF6-15-36 has a factor of 6.8 x OD for e-chain. Also verify conductor count, voltage rating (300 V), and environmental resistance like UV protection. Consult CHAINFLEX documentation for specific carrier compatibility.

Used in

Common applications for CHAINFLEX
Automated assembly lines — Chainflex CF10 control cables for signal transmission in cable carriers
Robotic arms — Chainflex CF280ULH servo motor cables for power and feedback in high-flex joints
Material handling conveyors — Chainflex CF78-UL control cables with PUR jacket for oil resistance
CNC machining centers — Chainflex CF9-UL control cables rated at 1,000 V for spindle and axis control
Packaging machinery — Chainflex CFBUS-PVC-021 bus cables for CAN-Bus communication in continuous motion
Automotive manufacturing — Chainflex CF2 control cables with UV-resistant PUR jacket for outdoor gantry systems

CHAINFLEX Products

3G Electric supplies CHAINFLEX continuous flexing control cables. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
CHAINFLEX Control Cable: 16 AWG, 18 Conductors, Order by the Foot, PVC Jacket, 300 V (MPN CF6-15-18). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: Oil and Grease Resistant; Standards: IPA 14644-1.
CHAINFLEX
CHAINFLEX Control Cable: 16 AWG, 18 Conductors, Order by the Foot, PVC Jacket, 300 V (MPN CF6-15-18). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: Oil and Grease Resistant; Standards: IPA 14644-1.
CHAINFLEX Control Cable: 17 AWG, 18 Conductors, Order by the Foot, PVC Jacket, 600 V (MPN CF6-10-18). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: UV/Sunlight Resistant; Standards: CTP C-DE.PB49.B.00416.
CHAINFLEX
CHAINFLEX Control Cable: 17 AWG, 18 Conductors, Order by the Foot, PVC Jacket, 600 V (MPN CF6-10-18). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: UV/Sunlight Resistant; Standards: CTP C-DE.PB49.B.00416.
CHAINFLEX Control Cable: 16 AWG, 36 Conductors, Order by the Foot, PVC Jacket, 600 V (MPN CF5-15-36). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: Oil and Grease Resistant; Standards: CE 2014/35/EU.
CHAINFLEX
CHAINFLEX Control Cable: 16 AWG, 36 Conductors, Order by the Foot, PVC Jacket, 600 V (MPN CF5-15-36). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: Oil and Grease Resistant; Standards: CE 2014/35/EU.
CHAINFLEX Control Cable: 16 AWG, 36 Conductors, Order by the Foot, PVC Jacket, 300 V (MPN CF140-15-36). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 7.5 x OD; Resistance Properties: Flame Retardant; Standards: CF130.15.07.UL ISO Class 1 (Outer Jacket Material).
CHAINFLEX
CHAINFLEX Control Cable: 16 AWG, 36 Conductors, Order by the Foot, PVC Jacket, 300 V (MPN CF140-15-36). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 7.5 x OD; Resistance Properties: Flame Retardant; Standards: CF130.15.07.UL ISO Class 1 (Outer Jacket Material).
CHAINFLEX Control Cable: 17 AWG, 25 Conductors, Order by the Foot, PVC Jacket, 300 V (MPN CF6-10-25). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: Oil and Grease Resistant; Standards: WTTC UL 2277.
CHAINFLEX
CHAINFLEX Control Cable: 17 AWG, 25 Conductors, Order by the Foot, PVC Jacket, 300 V (MPN CF6-10-25). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: Oil and Grease Resistant; Standards: WTTC UL 2277.
CHAINFLEX Control Cable: 16 AWG, 36 Conductors, Order by the Foot, PVC Jacket, 300 V (MPN CF130-15-36). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 7.5 x OD; Resistance Properties: Flame Retardant; Standards: FT-1.
CHAINFLEX
CHAINFLEX Control Cable: 16 AWG, 36 Conductors, Order by the Foot, PVC Jacket, 300 V (MPN CF130-15-36). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 6 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 7.5 x OD; Resistance Properties: Flame Retardant; Standards: FT-1.

More from CHAINFLEX

View all CHAINFLEX parts
CHAINFLEX Control Cable: 14 AWG, 5 Conductors, 25 ft, PVC Jacket, 600 V (MPN CF5-25-05-25). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: Heat Resistant; Standards: CE.
CHAINFLEX
CHAINFLEX Control Cable: 14 AWG, 5 Conductors, 25 ft, PVC Jacket, 600 V (MPN CF5-25-05-25). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: Heat Resistant; Standards: CE.
CHAINFLEX Control Cable: 18 AWG, 25 Conductors, Order by the Foot, PVC Jacket, 300 V (MPN CF881-07-25). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 7 x OD; Minimum Bend Radius Factor - Flexible: 10 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 12.5 x OD; Resistance Properties: Oil and Grease Resistant; Standards: CE 2014/35/EU.
CHAINFLEX
CHAINFLEX Control Cable: 18 AWG, 25 Conductors, Order by the Foot, PVC Jacket, 300 V (MPN CF881-07-25). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 7 x OD; Minimum Bend Radius Factor - Flexible: 10 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 12.5 x OD; Resistance Properties: Oil and Grease Resistant; Standards: CE 2014/35/EU.
CHAINFLEX Control Cable: 17 AWG, 12 Conductors, Order by the Foot, PVC Jacket, 600 V (MPN CF6-10-12). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: Oil and Grease Resistant; Standards: IEC 60332-1-2.
CHAINFLEX
CHAINFLEX Control Cable: 17 AWG, 12 Conductors, Order by the Foot, PVC Jacket, 600 V (MPN CF6-10-12). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: Oil and Grease Resistant; Standards: IEC 60332-1-2.
CHAINFLEX Control Cable: 20 AWG, 25 Conductors, Order by the Foot, PUR Jacket, 600 V (MPN CF890-05-25). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 7 x OD; Minimum Bend Radius Factor - Flexible: 10 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 12.5 x OD; Resistance Properties: UV/Sunlight Resistant; Standards: VW-1.
CHAINFLEX
CHAINFLEX Control Cable: 20 AWG, 25 Conductors, Order by the Foot, PUR Jacket, 600 V (MPN CF890-05-25). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 7 x OD; Minimum Bend Radius Factor - Flexible: 10 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 12.5 x OD; Resistance Properties: UV/Sunlight Resistant; Standards: VW-1.
CHAINFLEX Control Cable: 18 AWG, 4 Conductors, 25 ft, PVC Jacket, 600 V (MPN CF5-07-04-25). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: Oil and Grease Resistant; Standards: CE.
CHAINFLEX
CHAINFLEX Control Cable: 18 AWG, 4 Conductors, 25 ft, PVC Jacket, 600 V (MPN CF5-07-04-25). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: Oil and Grease Resistant; Standards: CE.
CHAINFLEX Control Cable: 18 AWG, 18 Conductors, 25 ft, PVC Jacket, 600 V (MPN CF6-07-18-25). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: Heat Resistant; Standards: CE.
CHAINFLEX
CHAINFLEX Control Cable: 18 AWG, 18 Conductors, 25 ft, PVC Jacket, 600 V (MPN CF6-07-18-25). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 4 x OD; Minimum Bend Radius Factor - Flexible: 5 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 6.8 x OD; Resistance Properties: Heat Resistant; Standards: CE.
CHAINFLEX Control Cable: 20 AWG, 4 Conductors, Order by the Foot, TPR Jacket, 300 V (MPN CF9-05-04-1). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 3 x OD; Minimum Bend Radius Factor - Flexible: 4 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 5 x OD; Resistance Properties: Coolant Resistant; Standards: DIN 47100.
CHAINFLEX
CHAINFLEX Control Cable: 20 AWG, 4 Conductors, Order by the Foot, TPR Jacket, 300 V (MPN CF9-05-04-1). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 3 x OD; Minimum Bend Radius Factor - Flexible: 4 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 5 x OD; Resistance Properties: Coolant Resistant; Standards: DIN 47100.
CHAINFLEX Control Cable: 20 AWG, 25 Conductors, Order by the Foot, PVC Jacket, 300 V (MPN CF881-05-25). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 7 x OD; Minimum Bend Radius Factor - Flexible: 10 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 12.5 x OD; Resistance Properties: Oil and Grease Resistant; Standards: FT-1.
CHAINFLEX
CHAINFLEX Control Cable: 20 AWG, 25 Conductors, Order by the Foot, PVC Jacket, 300 V (MPN CF881-05-25). Key specifications — Conductor Material: Copper; Conductor Configuration: Single; Minimum Bend Radius Factor - Fixed: 7 x OD; Minimum Bend Radius Factor - Flexible: 10 x OD; Includes Ground: Yes; Minimum Bend Radius Factor - E-Chain: 12.5 x OD; Resistance Properties: Oil and Grease Resistant; Standards: FT-1.