The CHEMETRICS Water Quality Test Kit: Chloride (SKU K-2070, MPN K-2070) is a water quality test kit designed for measuring chloride levels. It offers a range of 10,000 to 100,000 ppm with a sensitivity of 10,000 ppm…

SKU 3G-OTH-376593

Also listed as: K2070 · K 2070

Brand
CHEMETRICS
Item
Chloride Test Kit, 10,000 to 100,000 ppm, 30 Tests, K-2070
Part Number
K-2070
Category
Water Quality Test Kits
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Compliance & shipping

Hazardous material
Yes — hazmat handling and paperwork applyHazardous Material
California Prop 65 warning
Warning appliesProp 65 warning
Licence required
No licence required
Safety Data Sheet
Not available
Special shipping
Required — additional freight charges may applyThis item requires special shipping, additional charges may apply.

Technical Specifications

CHEMETRICS
Manufacturer Part Number
K-2070
Type
10,000 to 100,000 ppm, 10,000 ppm
Tests
30
Mfr. Model
K-2070
Number of Tests
30
www.P65Warnings.ca.gov
.

Datasheet Content

TECHNICAL DATA SHEET Chloride - Mercuric Nitrate Method Version 9 / Aug. 2025 Applications and Industries Interference Information Drinking water, surface waters, seawater, domestic and • Bromide and iodide are titrated along with chloride causing industrial wastewater. a false positive result. • Chromate and sulfite may interfere when present in excess References of 10 ppm. ASTM D 512 – 04, Chloride Ion in Water, Test Method A • Sulfide is expected to interfere. APHA Standard Methods, 23rd ed., Method 4500 CI- C -1997 EPA Methods for Chemical Analysis of Water and Wastes, • Nitrite interferes significantly. This chemistry is not method 325.3 (1983). applicable for the analysis of nitrite-treated cooling waters. • Copper should not interfere at levels below 50 ppm. Chemistry • Ferrous and ferric iron do not affect the accuracy of the test In an acidic solution, mercuric nitrate reacts with chloride to if present at up to 125 ppm, unless hydrogen peroxide is form mercuric chloride. Diphenylcarbazone, the endpoint present. Iron may alter the solution and/or end point colors. indicator, forms a purple complex with excess mercuric ions. • Hydrogen peroxide, in the presence of iron, prevents the Results are expressed as ppm (mg/L) Cl-. formation of the purple color, causing a false high result. Available Analysis Systems Addition of 2% EDTA to the sample prior to analysis will Titrimetric: Titrets® help to minimize the interference. Hydrogen peroxide alone at up to 125 ppm does not interfere. Storage Requirements • Zinc, lead, nickel, and chromous ion may alter the solution Products should be stored in the dark and at room and/or endpoint color but should not affect the accuracy of temperature. the test if present at up to 100 ppm. Shelf Life • QACs interfere if present at ppm levels. When stored in the dark and at room temperature: • Deep sample color may interfere. Titrets® kit: at least 1 year • Samples with high pHs or that are buffered to a pH above approximately 3 may cause a white precipitate to form in Accuracy Statement the test ampoule and prevent the formation of the purple Statements of accuracy are based on laboratory tests color, causing a false positive test result. The pH of such performed under ideal testing conditions using standards of samples can be adjusted with 0.1N Nitric Acid (HNO3) prior known concentration prepared in deionized water. to analysis. Sample pHs of less than 3 may limit the ability Due to the non-linear nature of the test scale, the accuracy of of the indicator to form the purple color, also causing false these tests varies with the location of the test result on the high results. Sodium hydroxide (NaOH), but not sodium scale. At twice the minimum concentration for a particular kit carbonate (Na2CO3), can be used to adjust the sample pH range, the accuracy is ± 10% error. to near neutral prior to analysis. Safety Information Interpretation of Results Safety Data Sheets (SDS) are available upon request and at At the endpoint of this titration, the color of the solution in the www.sdsfetch.com. Read SDS before using these products. test ampoule changes from purple to colorless. If the Titret® Breaking the tip of an ampoule in air when a valve assembly is ampoule is filled with sample but the color of the solution not attached may cause the glass ampoule to shatter. Wear remains purple (does not change to colorless), the chloride safety glasses and protective gloves. concentration is below the test range. If the solution in the Note: These products contain mercury and must be disposed ampoule is colorless immediately upon introduction of the first of according to local, state and federal laws. small dose of sample, add additional small doses to ensure the purple color does not appear. If no purple appears, the chloride concentration is above the test range. 4295 Catlett Rd., Midland, VA 22728 │ 800.356.3072 │ tech@aquaphoenixsci.com

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CHEMETRICS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The CHEMETRICS Water Quality Test Kit: Chloride (SKU K-2070, MPN K-2070) is a water quality test kit designed for measuring chloride levels. It offers a range of 10,000 to 100,000 ppm with a sensitivity of 10,000 ppm and includes a Titrettor for testing. The kit provides 30 tests per unit.

Frequently Asked Questions

What is the CHEMETRICS K-2070 water quality test kit used for?

The CHEMETRICS K-2070 test kit measures chloride levels in water, with a range of 10,000 to 100,000 ppm and a sensitivity of 10,000 ppm. It is used in industrial water treatment, wastewater monitoring, and process control applications where high chloride concentrations must be verified.

What are the specifications of the CHEMETRICS K-2070 chloride test kit?

The CHEMETRICS K-2070 (MPN K-2070) tests chloride from 10,000 to 100,000 ppm with a sensitivity of 10,000 ppm. It includes a Titrettor and provides 30 tests per kit. The kit is designed for high-range chloride analysis in industrial water quality testing.

Where to buy the CHEMETRICS K-2070 chloride test kit worldwide?

3G Electric supplies the CHEMETRICS K-2070 chloride test kit worldwide. As a global industrial solutions provider, we handle logistics, customs clearance, and delivery to your facility. Contact us to order this water quality test kit for your application.

How to use the CHEMETRICS K-2070 chloride test kit?

To use the CHEMETRICS K-2070, follow the included Titrettor instructions for titrimetric analysis. Fill the sample cup, add reagent, and titrate until the endpoint color change. Record the volume used and read the chloride concentration from the conversion chart. Always wear appropriate PPE.

Used in

Common applications for CHEMETRICS
Boiler water treatment — CHEMETRICS Chemical Oxygen Demand kit (K-7355) for monitoring organic contaminants in feedwater.
Wastewater effluent monitoring — CHEMETRICS Total Chlorine kit (K-2513) for compliance testing of disinfection residuals.
Cooling tower management — CHEMETRICS Ozone kit (I-2019) for tracking ozone levels in recirculating water systems.
Industrial process water — CHEMETRICS Hydrogen Peroxide kit (K-5520B) for verifying peroxide concentrations in bleaching or cleaning operations.
Groundwater analysis — CHEMETRICS Iron kit (K-6002) for detecting iron contamination in well water or remediation sites.
Drinking water disinfection — CHEMETRICS Monochloramine kit (K-6802) for monitoring chloramine levels in municipal distribution systems.
Not sure this is the right part? Photo-identify it

CHEMETRICS Products

3G Electric supplies CHEMETRICS water quality test kits. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This test kit measures chloride concentration in water over a range of 1,000 to 10,000 ppm with a sensitivity of 1,000 ppm. It includes Activator Solution and provides 30 tests per kit. Used for water quality monitoring in industrial and environmental applications
CHEMETRICS
This test kit measures chloride concentration in water over a range of 1,000 to 10,000 ppm with a sensitivity of 1,000 ppm. It includes Activator Solution and provides 30 tests per kit. Used for water quality monitoring in industrial and environmental applications
This test kit measures chloride concentration in water samples over a range of 50 to 500 ppm with a sensitivity of 50 ppm. It includes an Activator Solution and provides 30 tests per kit. Typical applications include monitoring chloride levels in industrial process water, wastewater, and environmental samples
CHEMETRICS
This test kit measures chloride concentration in water samples over a range of 50 to 500 ppm with a sensitivity of 50 ppm. It includes an Activator Solution and provides 30 tests per kit. Typical applications include monitoring chloride levels in industrial process water, wastewater, and environmental samples
This test kit measures chloride concentration in water across a range of 250 to 2,500 ppm with a sensitivity of 250 ppm. It includes an Activator Solution and provides 30 tests per kit. Typical applications include monitoring chloride levels in industrial water treatment, environmental sampling, and process control
CHEMETRICS
This test kit measures chloride concentration in water across a range of 250 to 2,500 ppm with a sensitivity of 250 ppm. It includes an Activator Solution and provides 30 tests per kit. Typical applications include monitoring chloride levels in industrial water treatment, environmental sampling, and process control
This test kit measures chloride concentration in water over a range of 20 to 200 ppm with a sensitivity of 20 ppm. It includes 30 ampoules with valve assemblies for performing up to 30 tests. Typical applications include industrial water treatment, environmental monitoring, and process control
CHEMETRICS
This test kit measures chloride concentration in water over a range of 20 to 200 ppm with a sensitivity of 20 ppm. It includes 30 ampoules with valve assemblies for performing up to 30 tests. Typical applications include industrial water treatment, environmental monitoring, and process control
This test kit measures chloride concentration in water over a range of 0 to 40 ppm. It includes an Ampoule Blank and provides 29 tests per kit. Sensitivity is ≤ 1.3 ppm at 0 ppm, ± 1.5 ppm at 5.0 ppm, ± 2.5 ppm at 10.0 ppm, and ± 4.5 ppm at 30.0 ppm. Typical applications include monitoring chloride levels in industrial water treatment and environmental water samples
CHEMETRICS
This test kit measures chloride concentration in water over a range of 0 to 40 ppm. It includes an Ampoule Blank and provides 29 tests per kit. Sensitivity is ≤ 1.3 ppm at 0 ppm, ± 1.5 ppm at 5.0 ppm, ± 2.5 ppm at 10.0 ppm, and ± 4.5 ppm at 30.0 ppm. Typical applications include monitoring chloride levels in industrial water treatment and environmental water samples
This test kit measures sulfide levels in water over a range of 1,000 to 10,000 ppm with a sensitivity of 1,000 ppm. It includes refill ampoules for 30 tests and is used for monitoring sulfide concentrations in industrial wastewater, environmental samples, and process water
CHEMETRICS
This test kit measures sulfide levels in water over a range of 1,000 to 10,000 ppm with a sensitivity of 1,000 ppm. It includes refill ampoules for 30 tests and is used for monitoring sulfide concentrations in industrial wastewater, environmental samples, and process water

More from CHEMETRICS

View all CHEMETRICS parts
This test kit measures sulfide concentration in water over a range of 125 to 1,250 ppm with a sensitivity of 125 ppm. It includes HR CHEMets® Refill Ampoules and provides 30 tests per kit. Suitable for monitoring sulfide levels in various water sources
CHEMETRICS
This test kit measures sulfide concentration in water over a range of 125 to 1,250 ppm with a sensitivity of 125 ppm. It includes HR CHEMets® Refill Ampoules and provides 30 tests per kit. Suitable for monitoring sulfide levels in various water sources
This test kit measures hydrogen peroxide concentration in water over a range of 125 to 1,250 ppm with a sensitivity of 125 ppm. It includes a 25 mL sample cup and provides 30 tests per kit. Suitable for monitoring peroxide levels in industrial water treatment and disinfection processes
CHEMETRICS
This test kit measures hydrogen peroxide concentration in water over a range of 125 to 1,250 ppm with a sensitivity of 125 ppm. It includes a 25 mL sample cup and provides 30 tests per kit. Suitable for monitoring peroxide levels in industrial water treatment and disinfection processes
This test kit measures ozone levels in water using pre-measured Vacu-Vials®. Range is 0 to 0.05 ppm, with 30 tests per kit. Sensitivity is ≤0.05 ppm at 0 ppm, ±0.06 ppm at 0.20 ppm, ±0.25 ppm at 1.25 ppm, and ±0.38 ppm at 3.75 ppm. Suitable for monitoring ozone in water treatment, aquaculture, and industrial process applications
CHEMETRICS
This test kit measures ozone levels in water using pre-measured Vacu-Vials®. Range is 0 to 0.05 ppm, with 30 tests per kit. Sensitivity is ≤0.05 ppm at 0 ppm, ±0.06 ppm at 0.20 ppm, ±0.25 ppm at 1.25 ppm, and ±0.38 ppm at 3.75 ppm. Suitable for monitoring ozone in water treatment, aquaculture, and industrial process applications
This test kit measures ozone concentration in water from 0 to 5 ppm. It includes a screwdriver and provides 30 tests per kit. Sensitivity is ≤0.05 ppm at 0 ppm, ±0.06 ppm at 0.20 ppm, ±0.25 ppm at 1.25 ppm, and ±0.38 ppm at 3.75 ppm. Typical applications include water treatment, aquaculture, and industrial process monitoring
CHEMETRICS
This test kit measures ozone concentration in water from 0 to 5 ppm. It includes a screwdriver and provides 30 tests per kit. Sensitivity is ≤0.05 ppm at 0 ppm, ±0.06 ppm at 0.20 ppm, ±0.25 ppm at 1.25 ppm, and ±0.38 ppm at 3.75 ppm. Typical applications include water treatment, aquaculture, and industrial process monitoring
This test kit measures iron levels in water over a range of 0 to 100 mg/L with a sensitivity of 5 mg/L. It includes Activator Solution and provides 30 tests. Suitable for field or laboratory analysis of dissolved iron in water samples for industrial water treatment and process monitoring
CHEMETRICS
This test kit measures iron levels in water over a range of 0 to 100 mg/L with a sensitivity of 5 mg/L. It includes Activator Solution and provides 30 tests. Suitable for field or laboratory analysis of dissolved iron in water samples for industrial water treatment and process monitoring
This test kit measures monochloramine levels in water over a range of 0 to 20 ppm with a sensitivity of 0.625 ppm. It includes a Stabilizer Solution and provides 30 tests per kit. Typical applications include water treatment and industrial process water testing
CHEMETRICS
This test kit measures monochloramine levels in water over a range of 0 to 20 ppm with a sensitivity of 0.625 ppm. It includes a Stabilizer Solution and provides 30 tests per kit. Typical applications include water treatment and industrial process water testing
This test kit measures total chlorine in water over a range of 0 to 5 ppm with a sensitivity of 0.25 ppm. It includes a 25 mL sample cup and uses a visual comparator method with increments of 0.12, 0.25, 0.2, and 0.38 ppm. Typical applications include monitoring disinfection levels in municipal water treatment, wastewater, and industrial process water
CHEMETRICS
This test kit measures total chlorine in water over a range of 0 to 5 ppm with a sensitivity of 0.25 ppm. It includes a 25 mL sample cup and uses a visual comparator method with increments of 0.12, 0.25, 0.2, and 0.38 ppm. Typical applications include monitoring disinfection levels in municipal water treatment, wastewater, and industrial process water
This test kit measures iron concentration in water over a range of 10 to 100 ppm with a sensitivity of 10 ppm. It includes a Flat Comparator for visual color matching and provides 30 tests per kit. Suitable for monitoring iron levels in water treatment and process control applications
CHEMETRICS
This test kit measures iron concentration in water over a range of 10 to 100 ppm with a sensitivity of 10 ppm. It includes a Flat Comparator for visual color matching and provides 30 tests per kit. Suitable for monitoring iron levels in water treatment and process control applications