Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

CLEVELAND CONTROLS Air Pressure Switches: Adj, Manual Reset, 0.08 in wc to 1 in wc, Open Mounted - Adjustable Set-Point Air Pressure Switches
CLEVELAND CONTROLSAdjustable Set-Point Air Pressure Switches

CLEVELAND CONTROLS Air Pressure Switches: Adj, Manual Reset, 0.08 in wc to 1 in wc, Open Mounted

The CLEVELAND CONTROLS ANS2-1000-00k is an adjustable set-point air pressure switch with a manual reset, SPDT switch action, and push-on terminals. It is open mounted and has a set-point range of 0.08 in wc to 1 in…

SKU 3G-OTH-69466

Also listed as: ANS2100000k · ANS2 1000 00k

Brand
CLEVELAND CONTROLS
Item
Air Pressure Switches: Adj, Manual Reset, 0.08 in wc to 1 in wc, Open Mounted
Category
Adjustable Set-Point Air Pressure Switches
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

CLEVELAND CONTROLS
Manufacturer Part Number
ANS2-1000-00k
Type
Manual Reset, 0.08 in wc to 1 in wc, Open Mounted, SPDT, Push-On

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CLEVELAND CONTROLS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The CLEVELAND CONTROLS ANS2-1000-00k is an adjustable set-point air pressure switch with a manual reset, SPDT switch action, and push-on terminals. It is open mounted and has a set-point range of 0.08 in wc to 1 in wc. 3G Electric interprets customer demand and delivers this genuine industrial component across 14 departments, with specialist depth in combustion, pumps and controls as an authorised distributor.

Frequently Asked Questions

What is the CLEVELAND CONTROLS ANS2-1000-00k air pressure switch used for?

The CLEVELAND CONTROLS ANS2-1000-00k is an adjustable set-point air pressure switch used in HVAC and industrial applications to monitor low air pressure or airflow. It features manual reset, SPDT contacts, and push-on terminals, making it suitable for safety interlocks or alarm systems in ducts, filters, or ventilation.

What are the specifications of the CLEVELAND CONTROLS ANS2-1000-00k?

The ANS2-1000-00k is a manual reset adjustable air pressure switch with a set-point range of 0.08 in wc to 1 in wc. It has an open-mounted design, SPDT switching, and push-on terminals. The manufacturer part number is ANS2-1000-00k from CLEVELAND CONTROLS.

Where to buy CLEVELAND CONTROLS ANS2-1000-00k worldwide?

3G Electric supplies the CLEVELAND CONTROLS ANS2-1000-00k air pressure switch worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your location. Contact us for availability and lead time.

How to install the CLEVELAND CONTROLS ANS2-1000-00k air pressure switch?

Mount the switch in a clean, dry location with the pressure port connected to the sensed air source. Adjust the set-point within the 0.08 to 1 in wc range using the adjustment screw. Wire the SPDT contacts according to your control circuit. Always follow local electrical codes and the manufacturer's manual.

Used in

Common applications for CLEVELAND CONTROLS
HVAC duct static pressure monitoring — Cleveland Controls static pressure probes (e.g., model 21118) used in air handling units
Burner draft pressure control — Cleveland Controls adjustable set-point switches (e.g., AFS-A) for combustion air proving
Industrial process air flow measurement — Cleveland Controls total pressure probes (e.g., model 21123) in ventilation systems
Building automation system pressure sensing — Cleveland Controls switches (e.g., RFS-4150) for filter clog detection
Exhaust fan interlock — Cleveland Controls pressure switches (e.g., AFS-222-112) for proving fan operation

CLEVELAND CONTROLS Products

3G Electric supplies CLEVELAND CONTROLS adjustable set-point air pressure switches. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Air Pressure Switch: Adj, Auto Reset, 0.1 in wc to 10 in wc, Open Mounted, SPDT, Push-On, 277V AC (MPN NS2-0000-00)
CLEVELAND CONTROLS
Air Pressure Switch: Adj, Auto Reset, 0.1 in wc to 10 in wc, Open Mounted, SPDT, Push-On, 277V AC (MPN NS2-0000-00)
Air Pressure Switch: Adj, Auto Reset, 0.03 in wc to 12 in wc, Open Mounted, SPDT, Barb (MPN AFS-298-112)
CLEVELAND CONTROLS
Air Pressure Switch: Adj, Auto Reset, 0.03 in wc to 12 in wc, Open Mounted, SPDT, Barb (MPN AFS-298-112)
Air Pressure Switch: Adj, Auto Reset, 0.1 in wc to 10 in wc, Open Mounted, SPDT, Push-On, 277V AC (MPN NS2-0000-01)
CLEVELAND CONTROLS
Air Pressure Switch: Adj, Auto Reset, 0.1 in wc to 10 in wc, Open Mounted, SPDT, Push-On, 277V AC (MPN NS2-0000-01)
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 2 in wc, Open Mounted, SPDT, 277V AC (MPN AFS-304)
CLEVELAND CONTROLS
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 2 in wc, Open Mounted, SPDT, 277V AC (MPN AFS-304)
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 2 in wc, Open Mounted, SPDT, Barb, 277V AC (MPN AFS-275-112)
CLEVELAND CONTROLS
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 2 in wc, Open Mounted, SPDT, Barb, 277V AC (MPN AFS-275-112)
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 12 in wc, Open Mounted, SPDT, Barb, 277V AC (MPN AFS-298-112-147)
CLEVELAND CONTROLS
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 12 in wc, Open Mounted, SPDT, Barb, 277V AC (MPN AFS-298-112-147)

More from CLEVELAND CONTROLS

View all CLEVELAND CONTROLS parts
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 12 in wc, Open Mounted, SPDT, Barb, 277V AC (MPN AFS-298-112-148)
CLEVELAND CONTROLS
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 12 in wc, Open Mounted, SPDT, Barb, 277V AC (MPN AFS-298-112-148)
Air Sensing Switch: Adj, Auto Reset, 0.1 in wc to 10 in wc, Open Mounted, SPDT, Push-On, 277V AC (MPN NS2-0000-05)
CLEVELAND CONTROLS
Air Sensing Switch: Adj, Auto Reset, 0.1 in wc to 10 in wc, Open Mounted, SPDT, Push-On, 277V AC (MPN NS2-0000-05)
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 12 in wc, Open Mounted, SPDT, 115 to 277V AC (MPN AFS-227-161)
CLEVELAND CONTROLS
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 12 in wc, Open Mounted, SPDT, 115 to 277V AC (MPN AFS-227-161)
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 12 in wc, Conduit Box, SPDT, 277V AC (MPN AFS-222-136)
CLEVELAND CONTROLS
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 12 in wc, Conduit Box, SPDT, 277V AC (MPN AFS-222-136)
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 12 in wc, Open Mounted, SPDT, 277V AC (MPN AFS-228)
CLEVELAND CONTROLS
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 12 in wc, Open Mounted, SPDT, 277V AC (MPN AFS-228)
Air Pressure Switch: Adj, Auto Reset, 0.03 in wc to 2 in wc, Conduit Box, SPDT, Barb, 277V AC (MPN AFS-398-112)
CLEVELAND CONTROLS
Air Pressure Switch: Adj, Auto Reset, 0.03 in wc to 2 in wc, Conduit Box, SPDT, Barb, 277V AC (MPN AFS-398-112)
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 12 in wc, Conduit Box, SPDT, NPT, 277V AC (MPN AFS-A-173)
CLEVELAND CONTROLS
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 12 in wc, Conduit Box, SPDT, NPT, 277V AC (MPN AFS-A-173)
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 2 in wc, Open Mounted, SPDT, 277V AC (MPN AFS-271)
CLEVELAND CONTROLS
Air Pressure Switch: Adj, Auto Reset, 0.05 in wc to 2 in wc, Open Mounted, SPDT, 277V AC (MPN AFS-271)