Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Image not available
CointraBurner Controls

Cointra Thermostatic valve M5,L5, Cointra

COINTRA thermostatic valve controls atmospheric gas burners in non-permanent operation with 2-4 mm spark gap and 2.5 VA consumption. Offers non-volatile and volatile lockout options with SELV safety circuit at 24V…

SKU 3G-CBM-05997

Also listed as: REL 45117 · REL-45117

Brand
Cointra
Item
Thermostatic valve M5,L5, Cointra
Category
Burner Controls
UNSPSC
40101833 — Boiler or heater igniter
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Cointra
series
MICROFLAT
spark gap
2-4 mm
application
atmospheric gas burners, non-permanent operation with or without fan
consumption
2.5 VA
lockout type
non-volatile and volatile
safety circuit
SELV type, 24V

Datasheet Content

MICROFLAT SERIES TYPES C.../U T… X… APPLICATION This range of electronic gas burner control systems is suitable AUTOMATIC GAS BURNER CONTROL for atmospheric gas burners for non-permanent operation with or without fan in the combustion circuit. SYSTEMS FOR GAS BURNERS AND GAS These controls are provided with both non volatile lockout, i.e. BURNING APPLIANCES WITH OR the restart from this condition is only possible by manual WITHOUT FAN reset, and volatile lockout, i.e. the restart from this condition is possible by the interruption and subsequent restoration of the mains supply. The automatic burner control units of this series are suitable for: – combi boilers – heating boilers – hot air generators – radiant heaters – water heaters. Thanks to the design and variety of models, they can also be used for the automation of ovens, cookers, stoves and in gas firing appliances with atmospheric burner in general. FEATURES Table 1 shows the main features of this series. Other important features are: − CE type certification in accordance with Gas Appliance Directive 90/396 and subsequent modifications 93/68 (see table 1); − in compliance with EN 298 (European standard for automatic gas burner flame monitoring and control systems); − flame monitoring based on the rectification property of the flame (ionization); − two independent safety contacts in series on the gas valve output; − electrical service life at max. declared loading > 250.000 operations; − inbuilt ignition device with completely solid state design and high efficiency; − auxiliary contact for low power ignition or main gas valve control for intermittent pilot systems type SELV, therefore suitable to control circuits type SELV - Safety Extra Low Voltage, e.g. 24V (see Table 1); − volatile lockout in case of flame loss in running condition for type CE12U NR. 4044_r03 1/6 BURNER OPTIONS Max. length of the cables of TABLE 1 external components: 1m Internal fuse rating: 3.15 A quick acting volatile lockout due to flame failure in running state External fuse rating: 2 A quick acting Flame monitoring: The flame detection device makes use of the rectification property of the flame (ionization). This device is not provided classification code according to 298 (2) with any protection impedance, therefore the flame detection electrode is not safe against electric shock. molex – Minimum ionization current: 1.2µA electrical reset from lockout safety thermostat provision on request: 0.5µA atmospheric without fan manual reset from lockout – Recommended ionization current: 3 ÷ 5 times the atmospheric with fan minimum ionization current – Max. length of the cable: 1m auxiliary contact – Minimum insulation resistance of cable and flame single flame double flame stelvio - stocko detection device to earth: ≥ 50MΩ Max. stray capacitance of the detection probe: ≤ 1nF CE PIN Max. short circuit current: < 200µA AC Ignition:…

Technical Documents

(1)
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Cointra Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

COINTRA thermostatic valve controls atmospheric gas burners in non-permanent operation with 2-4 mm spark gap and 2.5 VA consumption. Offers non-volatile and volatile lockout options with SELV safety circuit at 24V for burner control applications.

Frequently Asked Questions

What is the Cointra thermostatic valve M5, L5 used for?

The Cointra thermostatic valve M5, L5 is used to control atmospheric gas burners in non-permanent operation, with or without a fan. It is suitable for combi boilers, heating boilers, hot air generators, radiant heaters, and water heaters, as well as ovens, cookers, and stoves.

What are the specifications of the Cointra thermostatic valve M5, L5?

The Cointra thermostatic valve is part of the MICROFLAT series, with a spark gap of 2-4 mm and consumption of 2.5 VA. It offers both non-volatile and volatile lockout options, and features a SELV safety circuit at 24V. It complies with EN 298 and has an internal fuse rating of 3.15 A.

Where to buy the Cointra thermostatic valve M5, L5 in Singapore?

You can source the Cointra thermostatic valve M5, L5 through 3G Electric in Singapore. We handle logistics, customs clearance, and delivery to your location. Contact us for availability and lead time on this burner control component.

How to install the Cointra thermostatic valve M5, L5?

Install the Cointra thermostatic valve by connecting the SELV safety circuit at 24V and ensuring the spark gap is set to 2-4 mm. Use cables no longer than 1 m for external components. Follow the manufacturer's manual for proper wiring and lockout reset procedures.

Used in

Common applications for Cointra
Commercial boiler maintenance — Cointra 5L nozzles and thermostatic valve assemblies for scheduled pressure-burner overhaul and component replacement
Atmospheric gas-burner retrofit — MICROFLAT ignition-control modules for retrofitting or upgrading non-permanent-operation burner systems with 24 V safety logic
Thermal-control regulation — Cointra M10S and M5 thermostatic valves for modulating water or process-fluid temperature in heating loops and hot-water distribution networks
Burner-system fault recovery — Thermocouple and membrane-seal replacement to restore flame-detection and pressure-regulation function after thermal stress or electrode erosion
OEM boiler parts supply — Standardized Cointra nozzles, seals, and ignition components as plug-compatible spares for original-equipment service and warranty repair networks

Cointra Products

3G Electric supplies Cointra burner controls. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Gas Trains & Valves Ignition Transformers Burner Controls Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Thermostatic valve M10S Cointra 5274
Cointra
Thermostatic valve M10S Cointra 5274
Thermostatic valve CS10 Cointra 5238
Cointra
Thermostatic valve CS10 Cointra 5238
Safety valve M-H 1/2"(NF) 3bar Cointra 056110
Cointra
Safety valve M-H 1/2"(NF) 3bar Cointra 056110
Thermocouple M15 M20 MA20 Cointra 7576
Cointra
Thermocouple M15 M20 MA20 Cointra 7576
Satronic
Satronic
Relay CM 381N.4 TW5/TS5
Satronic
Satronic
Relay CM 391-2 Frisquet

More from Cointra

View all Cointra parts