Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

CYTIVA WHATMAN Filter Capsule - Capsule Filters
CYTIVA WHATMANCapsule Filters

CYTIVA WHATMAN Filter Capsule

The CYTIVA WHATMAN Filter Capsule (MPN 6710-7502) is a 75 mm diameter capsule filter with a PTFE membrane and polypropylene housing. It features tubing inlet and outlet connections with a 12 mm max inlet connection…

SKU 3G-OTH-361883

Also listed as: 67107502 · 6710 7502

Brand
CYTIVA WHATMAN
Item
Filter Capsule
Category
Capsule Filters
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

CYTIVA WHATMAN
Manufacturer Part Number
6710-7502
Type
Tubing, Filter Capsule, Tubing
Product Type
Filter Capsule
Filter Material
PTFE Membrane
Housing Material
Polypropylene
Max Inlet Connection
12 mm
Inlet Connection Type
Tubing
Outlet Connection Type
Tubing

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CYTIVA WHATMAN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The CYTIVA WHATMAN Filter Capsule (MPN 6710-7502) is a 75 mm diameter capsule filter with a PTFE membrane and polypropylene housing. It features tubing inlet and outlet connections with a 12 mm max inlet connection. This filter capsule is designed for industrial filtration applications requiring chemical compatibility and particulate removal.

Frequently Asked Questions

What is the CYTIVA WHATMAN Filter Capsule 6710-7502 used for?

This 75 mm capsule filter with a PTFE membrane and polypropylene housing is used for industrial filtration requiring chemical compatibility and particulate removal. It is suitable for applications where tubing connections are needed, such as in pharmaceutical, chemical, or laboratory processes.

What are the specifications of the CYTIVA WHATMAN Filter Capsule 6710-7502?

The CYTIVA WHATMAN Filter Capsule (MPN 6710-7502) has a 75 mm diameter, PTFE membrane filter material, polypropylene housing, and tubing inlet/outlet connections with a 12 mm max inlet connection. It is a capsule filter type designed for reliable particulate filtration.

Where to buy the CYTIVA WHATMAN Filter Capsule 6710-7502 worldwide?

3G Electric supplies the CYTIVA WHATMAN Filter Capsule 6710-7502 to customers worldwide. We handle full logistics, customs clearance, and delivery to your location. Contact us for pricing and lead time on this PTFE membrane capsule filter.

How to install the CYTIVA WHATMAN Filter Capsule 6710-7502?

Installation involves connecting the tubing to the 12 mm max inlet and outlet ports, ensuring a secure fit to prevent leaks. Follow standard industrial filtration practices: verify flow direction, pre-wet the PTFE membrane if required, and check housing integrity before use.

Used in

Common applications for CYTIVA WHATMAN
Environmental monitoring — Cytiva Whatman Grade C glass microfiber filters for particulate air sampling
Pharmaceutical quality control — Cytiva Whatman sterile syringe filters (0.45 µm PES) for sample filtration
Gravimetric analysis — Cytiva Whatman quantitative ashless filter paper Grade 40 for precipitate weighing
Industrial water testing — Cytiva Whatman pH indicator test strips (0–14 range) for quick pH checks
Microbiological analysis — Cytiva Whatman sterile MCE membrane filters (47 mm, 0.45 µm) for colony counting
Chemical processing — Cytiva Whatman hardened low ash filter paper Grade 52 for vacuum filtration of aggressive solutions

CYTIVA WHATMAN Products

3G Electric supplies CYTIVA WHATMAN capsule filters. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
This 36 mm diameter filter capsule is designed for venting applications, providing a compact solution to protect sensitive equipment from airborne contaminants in laboratory or process environments
CYTIVA WHATMAN
This 36 mm diameter filter capsule is designed for venting applications, providing a compact solution to protect sensitive equipment from airborne contaminants in laboratory or process environments
This inline filter features a PTFE membrane and polypropylene housing, with tubing inlet and outlet connections (max inlet 9.52 mm). It is used for inline filtration of fluids in laboratory and industrial processes where chemical resistance and particle removal are required
CYTIVA WHATMAN
This inline filter features a PTFE membrane and polypropylene housing, with tubing inlet and outlet connections (max inlet 9.52 mm). It is used for inline filtration of fluids in laboratory and industrial processes where chemical resistance and particle removal are required
This inline filter features a PTFE membrane and polypropylene housing with tubing inlet and outlet connections (max inlet 12.7 mm). It is used for particulate filtration in fluid systems, such as laboratory or process lines, to remove particles from liquids or gases
CYTIVA WHATMAN
This inline filter features a PTFE membrane and polypropylene housing with tubing inlet and outlet connections (max inlet 12.7 mm). It is used for particulate filtration in fluid systems, such as laboratory or process lines, to remove particles from liquids or gases
Non-sterile syringe filter with a 0.45 µm PTFE membrane and polypropylene housing. Features a female Luer Lock inlet and male Luer Slip outlet, with a 100 mL maximum capacity. Suitable for filtration of aggressive solvents and aqueous solutions in laboratory sample preparation and HPLC applications
CYTIVA WHATMAN
Non-sterile syringe filter with a 0.45 µm PTFE membrane and polypropylene housing. Features a female Luer Lock inlet and male Luer Slip outlet, with a 100 mL maximum capacity. Suitable for filtration of aggressive solvents and aqueous solutions in laboratory sample preparation and HPLC applications

More from CYTIVA WHATMAN

View all CYTIVA WHATMAN parts
This filter capsule is designed for venting applications in industrial systems. With a 150 mm diameter, it is used to maintain clean or sterile air flow by removing particulates and microorganisms from vent lines
CYTIVA WHATMAN
This filter capsule is designed for venting applications in industrial systems. With a 150 mm diameter, it is used to maintain clean or sterile air flow by removing particulates and microorganisms from vent lines
This filter capsule features a glass microfiber filter material and a polypropylene housing. It has barb-type inlet and outlet connections with a 12.7 mm max inlet connection. Suitable for inline filtration of liquids or gases in industrial processes
CYTIVA WHATMAN
This filter capsule features a glass microfiber filter material and a polypropylene housing. It has barb-type inlet and outlet connections with a 12.7 mm max inlet connection. Suitable for inline filtration of liquids or gases in industrial processes
This filter capsule features a nylon membrane with glass microfiber prefilter in a polypropylene housing. It has tubing inlet and outlet connections with a 9.52 mm max inlet connection. Suitable for filtration of aqueous solutions and solvents in laboratory sample preparation and HPLC mobile phase filtration
CYTIVA WHATMAN
This filter capsule features a nylon membrane with glass microfiber prefilter in a polypropylene housing. It has tubing inlet and outlet connections with a 9.52 mm max inlet connection. Suitable for filtration of aqueous solutions and solvents in laboratory sample preparation and HPLC mobile phase filtration
This filter capsule features a polypropylene filter medium and housing, with tubing-style inlet and outlet connections. The maximum inlet connection size is 12.7 mm. It is used for inline filtration of liquids and gases in industrial processes
CYTIVA WHATMAN
This filter capsule features a polypropylene filter medium and housing, with tubing-style inlet and outlet connections. The maximum inlet connection size is 12.7 mm. It is used for inline filtration of liquids and gases in industrial processes
This filter capsule features a polypropylene filter material and housing with tubing inlet and outlet connections (12.7 mm max inlet). It is used for industrial filtration of liquids and gases where chemical compatibility is required
CYTIVA WHATMAN
This filter capsule features a polypropylene filter material and housing with tubing inlet and outlet connections (12.7 mm max inlet). It is used for industrial filtration of liquids and gases where chemical compatibility is required
This filter capsule features a PTFE membrane and polypropylene housing with tubing inlet and outlet connections (10 mm max inlet). Designed for compact inline filtration of liquids and gases in laboratory and industrial processes
CYTIVA WHATMAN
This filter capsule features a PTFE membrane and polypropylene housing with tubing inlet and outlet connections (10 mm max inlet). Designed for compact inline filtration of liquids and gases in laboratory and industrial processes
This filter capsule features a glass microfiber filter material for particulate removal and a polypropylene housing. It has barbed inlet and outlet connections with a 9.52 mm max inlet connection, suitable for inline filtration of liquids or gases in tubing systems
CYTIVA WHATMAN
This filter capsule features a glass microfiber filter material for particulate removal and a polypropylene housing. It has barbed inlet and outlet connections with a 9.52 mm max inlet connection, suitable for inline filtration of liquids or gases in tubing systems
This 75 mm diameter filter capsule features polypropylene filter and housing materials. It has tubing inlet and outlet connections with a 12.7 mm max inlet connection. Designed for liquid or gas filtration in laboratory and process applications requiring broad chemical compatibility
CYTIVA WHATMAN
This 75 mm diameter filter capsule features polypropylene filter and housing materials. It has tubing inlet and outlet connections with a 12.7 mm max inlet connection. Designed for liquid or gas filtration in laboratory and process applications requiring broad chemical compatibility