Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

3G Electric
CYTIVA WHATMAN Non-Sterile Syringe Filter - Non-Sterile Syringe Filters
CYTIVA WHATMANNon-Sterile Syringe Filters

CYTIVA WHATMAN Non-Sterile Syringe Filter

<p>The CYTIVA WHATMAN Non-Sterile Syringe Filter (MPN 6753-2502) is a high-performance filtration solution designed for laboratory and industrial applications. With a 0.2 µm pore size and nylon membrane, it…

SKU 3G-OTH-361382

Also listed as: 67532502 · 6753 2502

Brand
CYTIVA WHATMAN
Item
Non-Sterile Syringe Filter
Part Number
6753-2502
Category
Non-Sterile Syringe Filters
Available to Order
Also known as:6753-2502CYTIVA WHATMAN
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

CYTIVA WHATMAN
Manufacturer Part Number
6753-2502
Type
100 mL Max Capacity - mL, Male, Female
Pore Size
0.2 um
Product Type
Syringe Filter
Filter Material
Nylon
Housing Material
Polypropylene
Inlet Connection Type
Female Luer Lock
Outlet Connection Type
Male Luer Slip
Compatible Product Type
Female Luer Lock
Inlet Connection Gender
Female
Outlet Connection Gender
Male

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

CYTIVA WHATMAN Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

<p>The CYTIVA WHATMAN Non-Sterile Syringe Filter (MPN 6753-2502) is a high-performance filtration solution designed for laboratory and industrial applications. With a 0.2 µm pore size and nylon membrane, it effectively removes particulates and microorganisms from samples. This filter features a 100 mL maximum capacity, a female Luer lock inlet, and a male Luer slip outlet, ensuring secure and convenient connections. The polypropylene housing provides chemical compatibility and durability.</p><p>Ideal for use in pharmaceutical, biotechnology, and analytical laboratories, this filter is suitable for clarifying and sterilizing aqueous and organic solutions. As a Singapore-based supplier, 3G Electric offers this product with worldwide shipping, SGD quotes on request, and GST handled for local buyers. Enjoy fast delivery across Singapore and Southeast Asia.</p>

Frequently Asked Questions

What are the key specifications of this syringe filter?

The CYTIVA WHATMAN syringe filter has a 0.2 µm pore size, nylon membrane, 100 mL maximum capacity, female Luer lock inlet, and male Luer slip outlet. It is non-sterile and has a polypropylene housing.

Can I get a quote in SGD and what about delivery in Singapore?

Yes, 3G Electric provides SGD quotes on request. For Singapore buyers, GST is handled, and we offer fast delivery across Singapore and Southeast Asia.

Used in

Common applications for CYTIVA WHATMAN
Environmental monitoring — Cytiva Whatman Grade C glass microfiber filters for particulate air sampling
Pharmaceutical quality control — Cytiva Whatman sterile syringe filters (0.45 µm PES) for sample filtration
Gravimetric analysis — Cytiva Whatman quantitative ashless filter paper Grade 40 for precipitate weighing
Industrial water testing — Cytiva Whatman pH indicator test strips (0–14 range) for quick pH checks
Microbiological analysis — Cytiva Whatman sterile MCE membrane filters (47 mm, 0.45 µm) for colony counting
Chemical processing — Cytiva Whatman hardened low ash filter paper Grade 52 for vacuum filtration of aggressive solutions
Not sure this is the right part? Photo-identify it

CYTIVA WHATMAN Products

3G Electric supplies CYTIVA WHATMAN non-sterile syringe filters. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

More from CYTIVA WHATMAN

View all CYTIVA WHATMAN parts
Non-sterile syringe filter with 0.2 µm pore size nylon membrane and polypropylene housing. Maximum capacity 100 mL. Inlet: female luer lock; outlet: male luer slip. Used for sample filtration in laboratory and industrial applications, including HPLC sample preparation and solvent filtration
CYTIVA WHATMAN
Non-sterile syringe filter with 0.2 µm pore size nylon membrane and polypropylene housing. Maximum capacity 100 mL. Inlet: female luer lock; outlet: male luer slip. Used for sample filtration in laboratory and industrial applications, including HPLC sample preparation and solvent filtration
Non-sterile syringe filter with 0.2 µm pore size PTFE membrane and polypropylene housing. Features a female Luer Lock inlet and male Luer Slip outlet with 0.5 mL max capacity. Used for filtration of small-volume samples in laboratory and industrial settings, suitable for aqueous and organic solutions
CYTIVA WHATMAN
Non-sterile syringe filter with 0.2 µm pore size PTFE membrane and polypropylene housing. Features a female Luer Lock inlet and male Luer Slip outlet with 0.5 mL max capacity. Used for filtration of small-volume samples in laboratory and industrial settings, suitable for aqueous and organic solutions
Non-sterile syringe filter with 0.45 µm pore size glass microfiber media for particulate removal from liquid samples. Polypropylene housing with female Luer Lock inlet and male Luer Slip outlet. 1.4 mL max capacity. Suitable for general laboratory filtration applications
CYTIVA WHATMAN
Non-sterile syringe filter with 0.45 µm pore size glass microfiber media for particulate removal from liquid samples. Polypropylene housing with female Luer Lock inlet and male Luer Slip outlet. 1.4 mL max capacity. Suitable for general laboratory filtration applications
Non-sterile syringe filter with a 1 µm PTFE membrane and polypropylene housing. Features a female Luer Lock inlet and male Luer Slip outlet, with a maximum capacity of 100 mL. Suitable for filtration of small-volume samples in laboratory and industrial applications
CYTIVA WHATMAN
Non-sterile syringe filter with a 1 µm PTFE membrane and polypropylene housing. Features a female Luer Lock inlet and male Luer Slip outlet, with a maximum capacity of 100 mL. Suitable for filtration of small-volume samples in laboratory and industrial applications
Non-sterile syringe filter with 0.45 µm pore size nylon membrane and polypropylene housing. Features a female Luer Lock inlet and male Luer Slip outlet for secure attachment to syringes. Maximum capacity of 1.4 mL. Used for particulate removal from liquid samples prior to analysis in laboratory and industrial filtration applications
CYTIVA WHATMAN
Non-sterile syringe filter with 0.45 µm pore size nylon membrane and polypropylene housing. Features a female Luer Lock inlet and male Luer Slip outlet for secure attachment to syringes. Maximum capacity of 1.4 mL. Used for particulate removal from liquid samples prior to analysis in laboratory and industrial filtration applications
This non-sterile syringe filter features glass microfiber media with 0.7 µm pore size for particulate removal from liquids up to 100 mL. The polypropylene housing has a female Luer Lock inlet and male Luer Slip outlet, suitable for sample preparation and filtration in laboratory fluid processing
CYTIVA WHATMAN
This non-sterile syringe filter features glass microfiber media with 0.7 µm pore size for particulate removal from liquids up to 100 mL. The polypropylene housing has a female Luer Lock inlet and male Luer Slip outlet, suitable for sample preparation and filtration in laboratory fluid processing

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first