Send a part number, a photo, or a whole BOM — we supply it and stand behind it. EXW Singapore — collect from our office.

3G Electric
Dayton Clean Air Belt-Drive Fan without Drive, 30 in Blade, 1912-8056 cfm - Clean Air Belt-Drive Fans without Drive
DaytonClean Air Belt-Drive Fans without Drive

Dayton Clean Air Belt-Drive Fan without Drive, 30 in Blade, 1912-8056 cfm

The Dayton Axial Downblast Roof Exhaust Fan (Less Drive Pack, MPN) is an unassembled clean air belt-drive fan for industrial and commercial applications. It features a 30-inch blade, a square base, and is designed…

SKU 3G-OTH-80402

Brand
Dayton
Item
Clean Air Belt-Drive Fan without Drive, 30 in Blade, 1912-8056 cfm
Category
Clean Air Belt-Drive Fans without Drive
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
EXW Singapore
Collect or forward from our office
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.

Technical Specifications

Dayton
Type
For 1,912 cfm to 8,056 cfm Airflow
Blade
30 in
Assembly
Unassembled
Base Shape
Square
Application
Industrial and Commercial Applications
For Air Type
Clean Air
Drive Package
Less Drive Package
Mounting Location
Roof

Technical Documents

No technical documents available for this product.
Request documentation →
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dayton Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Dayton Axial Downblast Roof Exhaust Fan (Less Drive Pack, MPN) is an unassembled clean air belt-drive fan for industrial and commercial applications. It features a 30-inch blade, a square base, and is designed for roof mounting with airflow from 1,912 cfm to 8,056 cfm. This less drive package does not include the drive components.

Frequently Asked Questions

What is the Dayton Axial Downblast Roof Exhaust Fan () used for?

This Dayton fan is designed for industrial and commercial clean air exhaust applications. It mounts on the roof and moves air from 1,912 cfm to 8,056 cfm, making it suitable for ventilating warehouses, factories, and large commercial spaces.

What are the specifications of the Dayton fan?

The Dayton is an unassembled belt-drive fan with a 30-inch blade and a square base. It handles clean air only, delivers 1,912 to 8,056 cfm, and comes as a less drive package (no drive components included). It is designed for roof mounting in industrial or commercial settings.

Where to buy the Dayton fan worldwide?

3G Electric supplies the Dayton axial downblast roof exhaust fan to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us to order this less drive package unit for your industrial or commercial ventilation project.

How to install the Dayton less drive fan?

Since this is a less drive package, you must supply and install the motor, belt, and pulley separately. Mount the square base securely on a roof curb, connect ductwork, and ensure the fan handles only clean air. Follow Dayton's manual for belt tension and alignment.

Used in

Common applications for Dayton
Manufacturing — Dayton 21XJ72 motor for machine tool coolant pumps circulates coolant during cutting, grinding, and drilling operations.
Water management — Dayton 3YU59 submersible sump pump removes water from basements, crawl spaces, and construction sites.
HVAC — Dayton 804T11 unit heater provides supplemental heating in warehouses, workshops, and garages.
Power transmission — Dayton 2X897 pillow block bearing supports rotating shafts in conveyors, fans, and other machinery.
Workshop — Dayton 2LKR8 bench grinder sharpens tools and deburrs metal parts with dust exhaust for a cleaner environment.
Fluid handling — Dayton 5RGV6 fountain pump circulates and aerates water in decorative ponds and fountains.
Not sure this is the right part? Photo-identify it→

Dayton Products

3G Electric supplies Dayton clean air belt-drive fans without drive. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion →Pumps & Compressors →Spare Parts →All Products →

Compatible alternatives & equivalents

Cross-referenced by specification & description
Unassembled axial downblast roof exhaust fan for industrial and commercial clean air applications. Features a 24-inch blade, square base, and supports airflow from 1,352 cfm to 5,320 cfm. Supplied without drive package; drive components must be sourced separately
Dayton
Unassembled axial downblast roof exhaust fan for industrial and commercial clean air applications. Features a 24-inch blade, square base, and supports airflow from 1,352 cfm to 5,320 cfm. Supplied without drive package; drive components must be sourced separately
Belt-drive centrifugal downblast roof exhaust fan for clean air applications. Unassembled unit with a 13 1/4-inch wheel and square base, supplied without a drive package. Single-speed operation for roof mounting; not intended for high-static pressure use
Dayton
Belt-drive centrifugal downblast roof exhaust fan for clean air applications. Unassembled unit with a 13 1/4-inch wheel and square base, supplied without a drive package. Single-speed operation for roof mounting; not intended for high-static pressure use
This unassembled belt-drive centrifugal downblast roof exhaust fan is designed for clean air applications. It features a 21 1/2-inch wheel and a square base, supplied without a drive package. The single-speed fan is intended for roof mounting and is not suitable for high-static-pressure applications
Dayton
This unassembled belt-drive centrifugal downblast roof exhaust fan is designed for clean air applications. It features a 21 1/2-inch wheel and a square base, supplied without a drive package. The single-speed fan is intended for roof mounting and is not suitable for high-static-pressure applications

More from Dayton

View all Dayton parts →
This belt-drive fan is designed for roof-mounted exhaust in commercial or industrial buildings, moving general ventilation air. It features an 18 1/2-inch wheel, single speed, and a square base. Supplied unassembled without a drive package, it is intended for clean air applications and not for high-static-pressure use
Dayton
This belt-drive fan is designed for roof-mounted exhaust in commercial or industrial buildings, moving general ventilation air. It features an 18 1/2-inch wheel, single speed, and a square base. Supplied unassembled without a drive package, it is intended for clean air applications and not for high-static-pressure use
This belt-drive axial upblast roof exhaust fan is designed for high-volume air movement in industrial and commercial ventilation systems. It handles airflow from 17,378 cfm to 50,958 cfm and features a 54-inch blade. The fan is intended for roof-mounted exhaust applications to remove heat, fumes, and stale air from large spaces
Dayton
This belt-drive axial upblast roof exhaust fan is designed for high-volume air movement in industrial and commercial ventilation systems. It handles airflow from 17,378 cfm to 50,958 cfm and features a 54-inch blade. The fan is intended for roof-mounted exhaust applications to remove heat, fumes, and stale air from large spaces
This belt-drive axial upblast roof exhaust fan is designed for clean air applications requiring airflow from 11,600 to 19,212 cfm. The 36-inch blade and upblast configuration direct exhaust upward, away from the roof surface. Suitable for general ventilation in industrial and commercial settings
Dayton
This belt-drive axial upblast roof exhaust fan is designed for clean air applications requiring airflow from 11,600 to 19,212 cfm. The 36-inch blade and upblast configuration direct exhaust upward, away from the roof surface. Suitable for general ventilation in industrial and commercial settings
Unassembled clean air belt-drive fan for roof mounting. Square base, 36-inch blade, handles 2,580 to 10,406 cfm. Less drive package requires separate drive components. Suitable for industrial and commercial exhaust ventilation
Dayton
Unassembled clean air belt-drive fan for roof mounting. Square base, 36-inch blade, handles 2,580 to 10,406 cfm. Less drive package requires separate drive components. Suitable for industrial and commercial exhaust ventilation
This unassembled belt-drive centrifugal fan is designed for clean-air roof exhaust applications. It features an 11-inch wheel and a square base, supplied without a drive package. The single-speed unit is suitable for general ventilation where high static pressure is not required
Dayton
This unassembled belt-drive centrifugal fan is designed for clean-air roof exhaust applications. It features an 11-inch wheel and a square base, supplied without a drive package. The single-speed unit is suitable for general ventilation where high static pressure is not required
This belt-drive axial upblast roof exhaust fan is designed for clean air applications, moving 11,471 to 32,495 cfm with a 42-inch blade. The upblast discharge directs exhaust upward, away from the roof surface, making it suitable for high-volume ventilation in industrial and commercial buildings. Supplied without a drive, it allows for custom integration into existing systems
Dayton
This belt-drive axial upblast roof exhaust fan is designed for clean air applications, moving 11,471 to 32,495 cfm with a 42-inch blade. The upblast discharge directs exhaust upward, away from the roof surface, making it suitable for high-volume ventilation in industrial and commercial buildings. Supplied without a drive, it allows for custom integration into existing systems
Unassembled axial downblast roof exhaust fan for clean air in industrial and commercial settings. Features a 20-inch blade and square base, designed for roof mounting. Supports airflow from 960 cfm to 3,957 cfm. Supplied without drive package
Dayton
Unassembled axial downblast roof exhaust fan for clean air in industrial and commercial settings. Features a 20-inch blade and square base, designed for roof mounting. Supports airflow from 960 cfm to 3,957 cfm. Supplied without drive package
Belt-drive centrifugal downblast roof exhaust fan for general clean-air ventilation. Unassembled unit with a 14-inch wheel and square base. Single-speed motor. Supplied without drive package. Not for high-static-pressure applications
Dayton
Belt-drive centrifugal downblast roof exhaust fan for general clean-air ventilation. Unassembled unit with a 14-inch wheel and square base. Single-speed motor. Supplied without drive package. Not for high-static-pressure applications

Customer reviews

No reviews yet — be the first

Questions & answers

No questions yet — ask us the first