Dayton Flammable Vapor Belt-Drive Fan with Drive, 18 1/2 in Wheel, 4,608 cfm - Flammable Vapor Belt-Drive Fans with Drive
DaytonFlammable Vapor Belt-Drive Fans with Drive

Dayton Flammable Vapor Belt-Drive Fan with Drive, 18 1/2 in Wheel, 4,608 cfm

The Dayton Centrifugal Downblast Roof Exhaust Fan (SKU 3G-OTH-81499) is a flammable vapor belt-drive fan with drive, featuring a belt drive and a square base. It is rated for hazardous locations including Class I…

SKU 3G-OTH-81499

Brand
Dayton
Item
Flammable Vapor Belt-Drive Fan with Drive, 18 1/2 in Wheel, 4,608 cfm
Category
Flammable Vapor Belt-Drive Fans with Drive
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Dayton
Type
Includes Drive Pack, 4,608 cfm
Wheel
18 1/2 in
Assembly
Unassembled
Base Shape
Square
Drive Package
Includes Drive Package
Motor Enclosure
Totally Enclosed Fan Cooled
Motor Efficiency
Standard-Efficiency Motors
Number of Speeds
1
Mounting Location
Roof
Nameplate Voltage
208-230/460V AC
High-Efficiency Motor
No
Hazardous Location Rating
Class I Groups C & D, Class II Groups E, F & G
Hazardous Location Specification
Class I Group C, Class I Group D, Class II Group E, Class II Group F, Class II Group G
Exhaust Airflow @ 0.000 in SP - Range
2,000 to 4,999 cfm
Exhaust Airflow @ 0.500 in SP - Range
2,000 to 4,999 cfm
For High-Static Pressure Applications
No

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dayton Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Dayton Centrifugal Downblast Roof Exhaust Fan (SKU 3G-OTH-81499) is a flammable vapor belt-drive fan with drive, featuring a belt drive and a square base. It is rated for hazardous locations including Class I Groups C & D and Class II Groups E, F & G, with a totally enclosed fan cooled motor and a nameplate voltage of 208-230/460V AC. The fan delivers exhaust airflow ranges of 2,000 to 4,999 cfm at both 0.000 in SP and 0.500 in SP, and is unassembled with standard-efficiency motors.

Frequently Asked Questions

What is the Dayton centrifugal downblast roof exhaust fan used for?

The Dayton is a belt-drive roof exhaust fan designed for hazardous locations such as chemical plants or refineries. It handles flammable vapors and is rated Class I Groups C & D and Class II Groups E, F & G. It delivers 4,608 cfm for general ventilation in industrial settings.

What are the specifications of the Dayton roof exhaust fan?

The Dayton has an 18 1/2 in wheel, 4,608 cfm airflow, and a totally enclosed fan cooled motor. Nameplate voltage is 208-230/460V AC. It includes a drive pack, has a square base, and is unassembled. Motor efficiency is standard, not high-efficiency.

Where to buy the Dayton exhaust fan worldwide?

3G Electric supplies the Dayton centrifugal downblast roof exhaust fan worldwide. As a global industrial distributor, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.

How to install the Dayton belt-drive roof exhaust fan?

Installation requires mounting the unassembled fan on a roof curb, connecting ductwork, and wiring the motor per nameplate voltage (208-230/460V AC). Ensure proper support and seal all joints. Follow local codes and the manufacturer's manual for belt tension and alignment.

Used in

Common applications for Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Products

3G Electric supplies Dayton flammable vapor belt-drive fans with drive. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Belt-drive roof exhaust fan for hazardous locations rated Class I Groups C & D and Class II Groups E, F & G. Unassembled unit with 21 1/2 in wheel delivers 4,759 cfm. Includes drive package and totally enclosed fan cooled motor for 230/460V AC operation
Dayton
Belt-drive roof exhaust fan for hazardous locations rated Class I Groups C & D and Class II Groups E, F & G. Unassembled unit with 21 1/2 in wheel delivers 4,759 cfm. Includes drive package and totally enclosed fan cooled motor for 230/460V AC operation
This unassembled belt-drive fan includes a drive pack and a square base for roof mounting. It features an 18 1/2 in wheel and a totally enclosed fan-cooled standard-efficiency motor rated at 230/460V AC, single speed. Rated for hazardous locations Class I Groups C & D and Class II Groups E, F & G, it delivers 4,102 cfm exhaust airflow. Typical applications include ventilation in environments where flammable vapors or combustible dusts may be present
Dayton
This unassembled belt-drive fan includes a drive pack and a square base for roof mounting. It features an 18 1/2 in wheel and a totally enclosed fan-cooled standard-efficiency motor rated at 230/460V AC, single speed. Rated for hazardous locations Class I Groups C & D and Class II Groups E, F & G, it delivers 4,102 cfm exhaust airflow. Typical applications include ventilation in environments where flammable vapors or combustible dusts may be present
This unassembled belt-drive fan includes a drive package and is designed for roof-mount exhaust applications. It features an 18 1/2 in wheel delivering 3150 cfm, with a totally enclosed nonventilated motor rated for 230/460V AC. Suitable for hazardous locations classified as Class I Groups C & D and Class II Groups E, F & G, it is used to ventilate areas where flammable vapors or combustible dusts may be present
Dayton
This unassembled belt-drive fan includes a drive package and is designed for roof-mount exhaust applications. It features an 18 1/2 in wheel delivering 3150 cfm, with a totally enclosed nonventilated motor rated for 230/460V AC. Suitable for hazardous locations classified as Class I Groups C & D and Class II Groups E, F & G, it is used to ventilate areas where flammable vapors or combustible dusts may be present
This belt-drive downblast roof exhaust fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It includes a drive package and features a 30 1/2 in wheel delivering 7,694 cfm. The unassembled unit has a square base and a totally enclosed fan-cooled standard-efficiency motor (115/208-230V AC, 1 speed). Suitable for exhausting air in areas where flammable vapors or combustible dusts may be present
Dayton
This belt-drive downblast roof exhaust fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It includes a drive package and features a 30 1/2 in wheel delivering 7,694 cfm. The unassembled unit has a square base and a totally enclosed fan-cooled standard-efficiency motor (115/208-230V AC, 1 speed). Suitable for exhausting air in areas where flammable vapors or combustible dusts may be present
This unassembled belt-drive centrifugal downblast roof exhaust fan includes a drive pack and a 21 1/2 in wheel delivering 5,340 cfm. It features a totally enclosed fan-cooled motor rated 208-230/460V AC, single speed, with standard efficiency. Rated for hazardous locations Class I Groups C & D and Class II Groups E, F & G, it is suitable for ventilating areas with flammable vapors or combustible dusts
Dayton
This unassembled belt-drive centrifugal downblast roof exhaust fan includes a drive pack and a 21 1/2 in wheel delivering 5,340 cfm. It features a totally enclosed fan-cooled motor rated 208-230/460V AC, single speed, with standard efficiency. Rated for hazardous locations Class I Groups C & D and Class II Groups E, F & G, it is suitable for ventilating areas with flammable vapors or combustible dusts
This belt-drive fan is designed for roof mounting and includes a drive package. It features a 24 1/2 in wheel and delivers 4,637 cfm exhaust airflow. The totally enclosed fan-cooled motor operates at 115/208-230V AC, single speed. Suitable for hazardous locations rated Class I Groups C & D and Class II Groups E & F
Dayton
This belt-drive fan is designed for roof mounting and includes a drive package. It features a 24 1/2 in wheel and delivers 4,637 cfm exhaust airflow. The totally enclosed fan-cooled motor operates at 115/208-230V AC, single speed. Suitable for hazardous locations rated Class I Groups C & D and Class II Groups E & F

More from Dayton

View all Dayton parts
This belt-drive fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It features an 11-inch wheel, delivers 1526 cfm, and includes a drive pack. The totally enclosed nonventilated motor operates at 230/460V AC single-speed. Unassembled with a square base for roof mounting
Dayton
This belt-drive fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It features an 11-inch wheel, delivers 1526 cfm, and includes a drive pack. The totally enclosed nonventilated motor operates at 230/460V AC single-speed. Unassembled with a square base for roof mounting
This unassembled tubeaxial fan is designed for Class I Group C hazardous locations. It delivers 1,904 cfm at 0.000 in SP with a 12-inch blade, powered by a 1/2 hp, 3-phase, totally enclosed fan-cooled motor (208-230/460V AC, single speed). Includes a drive package, B-type spark-resistant construction, and is intended for horizontal mounting. Typical applications include ventilation of areas where flammable vapors or gases may be present
Dayton
This unassembled tubeaxial fan is designed for Class I Group C hazardous locations. It delivers 1,904 cfm at 0.000 in SP with a 12-inch blade, powered by a 1/2 hp, 3-phase, totally enclosed fan-cooled motor (208-230/460V AC, single speed). Includes a drive package, B-type spark-resistant construction, and is intended for horizontal mounting. Typical applications include ventilation of areas where flammable vapors or gases may be present
This belt-drive fan is designed for horizontal mounting and intended for use in hazardous locations classified as Class I Group C and D. It features a 60-inch blade, delivers 50,567 cfm at 0.000 in static pressure, and operates on 230/460V AC, 3-phase power with a single-speed, totally enclosed fan-cooled motor. The unassembled unit includes a drive package and has spark-resistant construction Type B
Dayton
This belt-drive fan is designed for horizontal mounting and intended for use in hazardous locations classified as Class I Group C and D. It features a 60-inch blade, delivers 50,567 cfm at 0.000 in static pressure, and operates on 230/460V AC, 3-phase power with a single-speed, totally enclosed fan-cooled motor. The unassembled unit includes a drive package and has spark-resistant construction Type B
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 24 in blade, delivers 10,310 cfm at 0.000 in SP, and is powered by a 3-phase, 230/460V AC motor with a totally enclosed fan-cooled enclosure. Rated for Class I Group C hazardous locations with spark-resistant construction Type B, it is intended for vertical mounting and includes a drive package
Dayton
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 24 in blade, delivers 10,310 cfm at 0.000 in SP, and is powered by a 3-phase, 230/460V AC motor with a totally enclosed fan-cooled enclosure. Rated for Class I Group C hazardous locations with spark-resistant construction Type B, it is intended for vertical mounting and includes a drive package
This belt-drive fan is designed for hazardous locations classified as Class I Groups C & D and Class II Groups E & F. It delivers 2,839 cfm with an 18 1/2 in wheel and includes a drive package. The fan is unassembled, mounts on a square roof base, and operates with a standard-efficiency totally enclosed nonventilated motor at 115/208-230V AC, single speed
Dayton
This belt-drive fan is designed for hazardous locations classified as Class I Groups C & D and Class II Groups E & F. It delivers 2,839 cfm with an 18 1/2 in wheel and includes a drive package. The fan is unassembled, mounts on a square roof base, and operates with a standard-efficiency totally enclosed nonventilated motor at 115/208-230V AC, single speed
This unassembled belt-drive fan is designed for hazardous locations classified as Class I Group C and D. It features a 42-inch blade delivering 25,320 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, totally enclosed fan-cooled motor. The unit includes a drive package, mounts horizontally, and has spark-resistant construction Type B for flammable vapor applications
Dayton
This unassembled belt-drive fan is designed for hazardous locations classified as Class I Group C and D. It features a 42-inch blade delivering 25,320 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, totally enclosed fan-cooled motor. The unit includes a drive package, mounts horizontally, and has spark-resistant construction Type B for flammable vapor applications
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 19,290 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, single-speed motor with a totally enclosed fan-cooled enclosure. The fan includes a drive package and is intended for vertical mounting. It meets Class I Group C and D hazardous location specifications with Spark Resistant Construction Type B
Dayton
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 19,290 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, single-speed motor with a totally enclosed fan-cooled enclosure. The fan includes a drive package and is intended for vertical mounting. It meets Class I Group C and D hazardous location specifications with Spark Resistant Construction Type B
This unassembled flammable vapor belt-drive fan is designed for horizontal mounting and includes a drive package. It features a 60-inch blade, a 3-phase totally enclosed nonventilated motor rated at 230/460V AC, and delivers 45,933 cfm at 0.000 in SP. Suitable for Class I Group C hazardous locations with spark-resistant construction type B
Dayton
This unassembled flammable vapor belt-drive fan is designed for horizontal mounting and includes a drive package. It features a 60-inch blade, a 3-phase totally enclosed nonventilated motor rated at 230/460V AC, and delivers 45,933 cfm at 0.000 in SP. Suitable for Class I Group C hazardous locations with spark-resistant construction type B