Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Dayton Flammable Vapor Belt-Drive Fan with Drive, 18 1/2 in Wheel, 4,477 cfm - Flammable Vapor Belt-Drive Fans with Drive
DaytonFlammable Vapor Belt-Drive Fans with Drive

Dayton Flammable Vapor Belt-Drive Fan with Drive, 18 1/2 in Wheel, 4,477 cfm

The Dayton Centrifugal Upblast Roof Exhaust Fan (SKU 3G-OTH-80706) is a flammable vapor belt-drive fan with drive, featuring an 18 1/2 in wheel and 4,477 cfm exhaust airflow. It is unassembled, includes a drive…

SKU 3G-OTH-80706

Brand
Dayton
Item
Flammable Vapor Belt-Drive Fan with Drive, 18 1/2 in Wheel, 4,477 cfm
Category
Flammable Vapor Belt-Drive Fans with Drive
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Dayton
Type
Includes Drive Pack, 4,477 cfm
Wheel
18 1/2 in
Assembly
Unassembled
Base Shape
Square
Drive Package
Includes Drive Package
Motor Enclosure
Totally Enclosed Fan Cooled
Motor Efficiency
Standard Motor
Number of Speeds
1
Mounting Location
Roof
Nameplate Voltage
115/208-230V AC
High-Efficiency Motor
No
Includes Drive Package
Yes
Hazardous Location Rating
Class I Groups C & D, Class II Groups E, F & G
Hazardous Location Specification
Class I Group C, Class I Group D, Class II Group E, Class II Group F, Class II Group G
Exhaust Airflow @ 0.000 in SP - Range
2,000 to 4,999 cfm
Exhaust Airflow @ 0.500 in SP - Range
2,000 to 4,999 cfm
For High-Static Pressure Applications
No

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dayton Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Dayton Centrifugal Upblast Roof Exhaust Fan (SKU 3G-OTH-80706) is a flammable vapor belt-drive fan with drive, featuring an 18 1/2 in wheel and 4,477 cfm exhaust airflow. It is unassembled, includes a drive package, and has a totally enclosed fan cooled standard motor with 1 speed at 115/208-230V AC. This square-base fan is rated for hazardous locations: Class I Groups C & D and Class II Groups E, F & G.

Frequently Asked Questions

What is the Dayton Centrifugal Upblast Roof Exhaust Fan used for?

The Dayton is a belt-drive roof exhaust fan designed for hazardous locations where flammable vapors may be present. It is rated Class I Groups C & D and Class II Groups E, F & G, making it suitable for industrial environments such as chemical plants, paint booths, and grain handling facilities.

What are the specifications of the Dayton roof exhaust fan?

The Dayton features an 18 1/2 in wheel, 4,477 cfm exhaust airflow, and a totally enclosed fan-cooled motor. It operates at 115/208-230V AC, single speed, and includes a drive package. The fan is unassembled with a square base for roof mounting and is rated for hazardous locations.

Where to buy the Dayton exhaust fan worldwide?

3G Electric supplies the Dayton centrifugal upblast roof exhaust fan to customers worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.

How to install the Dayton belt-drive roof exhaust fan?

Installation requires mounting the unassembled fan on a roof curb, connecting the motor to a 115/208-230V AC power supply, and assembling the drive package per Dayton's manual. Ensure proper sealing for hazardous location compliance. Always follow local electrical codes and use a licensed electrician.

Used in

Common applications for Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Products

3G Electric supplies Dayton flammable vapor belt-drive fans with drive. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Unassembled centrifugal upblast roof exhaust fan with belt drive and included drive package. Features an 18 1/2 in wheel, 5,648 cfm airflow, and a totally enclosed fan cooled motor rated 208-230/460V AC, single speed, standard efficiency. Square base for roof mounting. Rated for hazardous locations: Class I Groups C & D, Class II Groups E, F & G. Suitable for exhausting flammable vapors and airborne particulates in industrial environments
Dayton
Unassembled centrifugal upblast roof exhaust fan with belt drive and included drive package. Features an 18 1/2 in wheel, 5,648 cfm airflow, and a totally enclosed fan cooled motor rated 208-230/460V AC, single speed, standard efficiency. Square base for roof mounting. Rated for hazardous locations: Class I Groups C & D, Class II Groups E, F & G. Suitable for exhausting flammable vapors and airborne particulates in industrial environments
This belt-drive roof exhaust fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E, F & G. It features an 18 1/2 in wheel, delivers 3,098 cfm, and includes a drive package. The totally enclosed fan-cooled motor operates at 115/208-230V AC, single speed. The unit is unassembled with a square base, suitable for exhausting flammable vapors in industrial settings
Dayton
This belt-drive roof exhaust fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E, F & G. It features an 18 1/2 in wheel, delivers 3,098 cfm, and includes a drive package. The totally enclosed fan-cooled motor operates at 115/208-230V AC, single speed. The unit is unassembled with a square base, suitable for exhausting flammable vapors in industrial settings
Belt-drive centrifugal upblast roof exhaust fan for hazardous locations. Rated Class I Groups C & D and Class II Groups E, F & G. Includes drive package, 18 1/2 in wheel, 3551 cfm, 115/208-230V AC, 1-speed TEFC motor. Unassembled with square base
Dayton
Belt-drive centrifugal upblast roof exhaust fan for hazardous locations. Rated Class I Groups C & D and Class II Groups E, F & G. Includes drive package, 18 1/2 in wheel, 3551 cfm, 115/208-230V AC, 1-speed TEFC motor. Unassembled with square base
This belt-drive upblast roof exhaust fan is designed for hazardous locations where flammable vapors may be present. It features an 18 1/2 in wheel, delivers 4,477 cfm, and includes a drive package. The totally enclosed fan-cooled motor is rated 208-230/460V AC. Suitable for Class I Groups C & D and Class II Groups E, F & G environments
Dayton
This belt-drive upblast roof exhaust fan is designed for hazardous locations where flammable vapors may be present. It features an 18 1/2 in wheel, delivers 4,477 cfm, and includes a drive package. The totally enclosed fan-cooled motor is rated 208-230/460V AC. Suitable for Class I Groups C & D and Class II Groups E, F & G environments
This belt-drive roof exhaust fan is designed for hazardous locations classified as Class I Groups C & D and Class II Groups E, F & G. It features an 18 1/2 in wheel and delivers 4,061 cfm. The fan includes a drive package and is unassembled with a square base for roof mounting. Motor is totally enclosed fan-cooled, single speed, rated 115/208-230V AC
Dayton
This belt-drive roof exhaust fan is designed for hazardous locations classified as Class I Groups C & D and Class II Groups E, F & G. It features an 18 1/2 in wheel and delivers 4,061 cfm. The fan includes a drive package and is unassembled with a square base for roof mounting. Motor is totally enclosed fan-cooled, single speed, rated 115/208-230V AC
This belt-drive fan includes a drive package and is designed for hazardous locations rated Class I Groups C & D and Class II Groups E, F & G. It features an 18 1/2 in wheel, delivers 3,551 cfm, and is powered by a totally enclosed fan-cooled standard-efficiency motor (208-230/460V AC, 1 speed). The unassembled unit has a square base for roof mounting and is not intended for high-static-pressure applications
Dayton
This belt-drive fan includes a drive package and is designed for hazardous locations rated Class I Groups C & D and Class II Groups E, F & G. It features an 18 1/2 in wheel, delivers 3,551 cfm, and is powered by a totally enclosed fan-cooled standard-efficiency motor (208-230/460V AC, 1 speed). The unassembled unit has a square base for roof mounting and is not intended for high-static-pressure applications

More from Dayton

View all Dayton parts
This belt-drive fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It features an 11-inch wheel, delivers 1526 cfm, and includes a drive pack. The totally enclosed nonventilated motor operates at 230/460V AC single-speed. Unassembled with a square base for roof mounting
Dayton
This belt-drive fan is designed for hazardous locations rated Class I Groups C & D and Class II Groups E & F. It features an 11-inch wheel, delivers 1526 cfm, and includes a drive pack. The totally enclosed nonventilated motor operates at 230/460V AC single-speed. Unassembled with a square base for roof mounting
This unassembled tubeaxial fan is designed for Class I Group C hazardous locations. It delivers 1,904 cfm at 0.000 in SP with a 12-inch blade, powered by a 1/2 hp, 3-phase, totally enclosed fan-cooled motor (208-230/460V AC, single speed). Includes a drive package, B-type spark-resistant construction, and is intended for horizontal mounting. Typical applications include ventilation of areas where flammable vapors or gases may be present
Dayton
This unassembled tubeaxial fan is designed for Class I Group C hazardous locations. It delivers 1,904 cfm at 0.000 in SP with a 12-inch blade, powered by a 1/2 hp, 3-phase, totally enclosed fan-cooled motor (208-230/460V AC, single speed). Includes a drive package, B-type spark-resistant construction, and is intended for horizontal mounting. Typical applications include ventilation of areas where flammable vapors or gases may be present
This belt-drive fan is designed for horizontal mounting and intended for use in hazardous locations classified as Class I Group C and D. It features a 60-inch blade, delivers 50,567 cfm at 0.000 in static pressure, and operates on 230/460V AC, 3-phase power with a single-speed, totally enclosed fan-cooled motor. The unassembled unit includes a drive package and has spark-resistant construction Type B
Dayton
This belt-drive fan is designed for horizontal mounting and intended for use in hazardous locations classified as Class I Group C and D. It features a 60-inch blade, delivers 50,567 cfm at 0.000 in static pressure, and operates on 230/460V AC, 3-phase power with a single-speed, totally enclosed fan-cooled motor. The unassembled unit includes a drive package and has spark-resistant construction Type B
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 24 in blade, delivers 10,310 cfm at 0.000 in SP, and is powered by a 3-phase, 230/460V AC motor with a totally enclosed fan-cooled enclosure. Rated for Class I Group C hazardous locations with spark-resistant construction Type B, it is intended for vertical mounting and includes a drive package
Dayton
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 24 in blade, delivers 10,310 cfm at 0.000 in SP, and is powered by a 3-phase, 230/460V AC motor with a totally enclosed fan-cooled enclosure. Rated for Class I Group C hazardous locations with spark-resistant construction Type B, it is intended for vertical mounting and includes a drive package
This belt-drive fan is designed for hazardous locations classified as Class I Groups C & D and Class II Groups E & F. It delivers 2,839 cfm with an 18 1/2 in wheel and includes a drive package. The fan is unassembled, mounts on a square roof base, and operates with a standard-efficiency totally enclosed nonventilated motor at 115/208-230V AC, single speed
Dayton
This belt-drive fan is designed for hazardous locations classified as Class I Groups C & D and Class II Groups E & F. It delivers 2,839 cfm with an 18 1/2 in wheel and includes a drive package. The fan is unassembled, mounts on a square roof base, and operates with a standard-efficiency totally enclosed nonventilated motor at 115/208-230V AC, single speed
This unassembled belt-drive fan is designed for hazardous locations classified as Class I Group C and D. It features a 42-inch blade delivering 25,320 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, totally enclosed fan-cooled motor. The unit includes a drive package, mounts horizontally, and has spark-resistant construction Type B for flammable vapor applications
Dayton
This unassembled belt-drive fan is designed for hazardous locations classified as Class I Group C and D. It features a 42-inch blade delivering 25,320 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, totally enclosed fan-cooled motor. The unit includes a drive package, mounts horizontally, and has spark-resistant construction Type B for flammable vapor applications
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 19,290 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, single-speed motor with a totally enclosed fan-cooled enclosure. The fan includes a drive package and is intended for vertical mounting. It meets Class I Group C and D hazardous location specifications with Spark Resistant Construction Type B
Dayton
This unassembled belt-drive fan is designed for moving flammable vapors in hazardous locations. It features a 34-inch blade delivering 19,290 cfm at 0.000 in SP, powered by a 230/460V AC, 3-phase, single-speed motor with a totally enclosed fan-cooled enclosure. The fan includes a drive package and is intended for vertical mounting. It meets Class I Group C and D hazardous location specifications with Spark Resistant Construction Type B
This unassembled flammable vapor belt-drive fan is designed for horizontal mounting and includes a drive package. It features a 60-inch blade, a 3-phase totally enclosed nonventilated motor rated at 230/460V AC, and delivers 45,933 cfm at 0.000 in SP. Suitable for Class I Group C hazardous locations with spark-resistant construction type B
Dayton
This unassembled flammable vapor belt-drive fan is designed for horizontal mounting and includes a drive package. It features a 60-inch blade, a 3-phase totally enclosed nonventilated motor rated at 230/460V AC, and delivers 45,933 cfm at 0.000 in SP. Suitable for Class I Group C hazardous locations with spark-resistant construction type B