Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Dayton Type K Thermocouple Probe, Rounded Tip, 6 in Probe Length - Thermocouples for Gas Applications
DaytonThermocouples for Gas Applications

Dayton Type K Thermocouple Probe, Rounded Tip, 6 in Probe Length

The DAYTON is a Type K thermocouple probe for gas applications with a temperature range of -325°F to 2,280°F (-200°C to 1,250°C). It features a 6-inch probe length, 20 AWG wire, a rounded tip, and a weld junction…

SKU 3G-OTH-187448

Brand
Dayton
Item
Type K Thermocouple Probe, Rounded Tip, 6 in Probe Length
Category
Thermocouples for Gas Applications
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Dayton
Type
Type K, Rounded Tip
Probe Lg
6 in

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dayton Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DAYTON is a Type K thermocouple probe for gas applications with a temperature range of -325°F to 2,280°F (-200°C to 1,250°C). It features a 6-inch probe length, 20 AWG wire, a rounded tip, and a weld junction. Accuracy is ±1.1% below 293°C and ±0.4% otherwise.

Frequently Asked Questions

What is the DAYTON thermocouple probe used for?

The DAYTON Type K thermocouple probe is designed for gas applications requiring temperature measurement from -325°F to 2,280°F (-200°C to 1,250°C). Its rounded tip and weld junction suit industrial ovens, furnaces, and process heating systems where reliable, high-temperature sensing is needed.

What are the specifications of the DAYTON thermocouple probe?

The DAYTON is a Type K thermocouple probe with a 6-inch probe length, 20 AWG wire, and a weld junction. Accuracy is ±1.1% below 293°C and ±0.4% otherwise. It covers -325°F to 2,280°F (-200°C to 1,250°C) and has a rounded tip for gas applications.

Where to buy the DAYTON thermocouple probe worldwide?

3G Electric supplies the DAYTON thermocouple probe to customers worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your site. Contact us for pricing and lead time on this Type K probe for gas applications.

How to install a DAYTON thermocouple probe?

Install the DAYTON probe by inserting the 6-inch rounded tip into the gas stream or process area. Secure the probe using a compression fitting or thermowell, ensuring the weld junction is fully immersed. Connect the 20 AWG Type K wires to a compatible transmitter or controller, observing polarity.

Used in

Common applications for Dayton
HVAC ventilation — DAYTON centrifugal upblast roof exhaust fans (SKU 7M7U3) for kitchen exhaust systems
Mechanical power transmission — DAYTON HTD timing pulleys (SKU 404GV0) for conveyor belt drives
Process water handling — DAYTON self-priming centrifugal pumps (SKU 2ZXT4) for dewatering or transfer
Roofing and building services — DAYTON fixed ventilated roof curbs (SKU 4HX59) for filtered supply fan installations
Material handling — DAYTON latch assemblies (SKU 2KEN4) for electric chain hoist hook safety
Industrial air movement — DAYTON downblast roof exhaust fans (SKU 3HFL9) for clean air exhaust in manufacturing plants

Dayton Products

3G Electric supplies Dayton thermocouples for gas applications. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Type K thermocouple probe with a rounded tip and weld junction, 6 in probe length, 20 AWG wire gauge. Temperature range -325°F to 2,280°F (-200°C to 1,250°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise. Used for temperature measurement in gas-fired ovens, furnaces, and process heating systems
Dayton
Type K thermocouple probe with a rounded tip and weld junction, 6 in probe length, 20 AWG wire gauge. Temperature range -325°F to 2,280°F (-200°C to 1,250°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise. Used for temperature measurement in gas-fired ovens, furnaces, and process heating systems
Type K thermocouple probe with a 6-inch probe length and rounded tip, designed for gas applications such as monitoring flue or exhaust gas temperatures in industrial furnaces, boilers, and process heaters. Features a hose clamp for secure installation in gas ducts or pipes. Temperature range: -325°F to 2,280°F (-200°C to 1,250°C). Accuracy: ±1.1% below 293°C, ±0.4% otherwise
Dayton
Type K thermocouple probe with a 6-inch probe length and rounded tip, designed for gas applications such as monitoring flue or exhaust gas temperatures in industrial furnaces, boilers, and process heaters. Features a hose clamp for secure installation in gas ducts or pipes. Temperature range: -325°F to 2,280°F (-200°C to 1,250°C). Accuracy: ±1.1% below 293°C, ±0.4% otherwise
Type K thermocouple probe with a rounded tip and 24-inch probe length. Designed for temperature measurement in gas applications such as industrial furnaces, boilers, and process heating systems. Includes a hose clamp for mounting. Temperature range: -325°F to 2,280°F (-200°C to 1,250°C). Accuracy: ±1.1% below 293°C, ±0.4% otherwise
Dayton
Type K thermocouple probe with a rounded tip and 24-inch probe length. Designed for temperature measurement in gas applications such as industrial furnaces, boilers, and process heating systems. Includes a hose clamp for mounting. Temperature range: -325°F to 2,280°F (-200°C to 1,250°C). Accuracy: ±1.1% below 293°C, ±0.4% otherwise
Type K thermocouple probe with a 6-inch probe length, 20 AWG wire, and a rounded tip. Mounts via hose clamp. Temperature range -325°F to 2,280°F (-200°C to 1,250°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise. Suitable for gas applications such as industrial furnaces, boilers, and process heating systems
Dayton
Type K thermocouple probe with a 6-inch probe length, 20 AWG wire, and a rounded tip. Mounts via hose clamp. Temperature range -325°F to 2,280°F (-200°C to 1,250°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise. Suitable for gas applications such as industrial furnaces, boilers, and process heating systems
Type K thermocouple probe with a 24-inch length and rounded tip, suited for gas stream temperature measurement in industrial furnaces, boilers, and process heaters. Includes a hose clamp for secure installation. Temperature range: -325°F to 2,280°F (-200°C to 1,250°C)
Dayton
Type K thermocouple probe with a 24-inch length and rounded tip, suited for gas stream temperature measurement in industrial furnaces, boilers, and process heaters. Includes a hose clamp for secure installation. Temperature range: -325°F to 2,280°F (-200°C to 1,250°C)
Type J thermocouple probe with a 24-inch probe length, 20 AWG wire gauge, and a rounded tip with weld junction. Temperature range -346°F to 2,193°F (-210°C to 1,200°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise. Used for temperature measurement in gas-fired ovens, furnaces, and process heating systems
Dayton
Type J thermocouple probe with a 24-inch probe length, 20 AWG wire gauge, and a rounded tip with weld junction. Temperature range -346°F to 2,193°F (-210°C to 1,200°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise. Used for temperature measurement in gas-fired ovens, furnaces, and process heating systems

More from Dayton

View all Dayton parts
Type K thermocouple probe with a 24-inch probe length, rounded tip, and weld junction. Suitable for temperature measurement in gas-fired ovens, furnaces, and process heating systems. Temperature range -325°F to 2,280°F (-200°C to 1,250°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise
Dayton
Type K thermocouple probe with a 24-inch probe length, rounded tip, and weld junction. Suitable for temperature measurement in gas-fired ovens, furnaces, and process heating systems. Temperature range -325°F to 2,280°F (-200°C to 1,250°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise
Type J thermocouple probe with a rounded tip and 18-inch probe length, 20 AWG wire. Temperature range -210°C to 1,200°C (-346°F to 2,193°F) with accuracy ±1.1% below 293°C and ±0.4% otherwise. Includes hose clamp for installation in gas ducts or pipes for monitoring flue or exhaust gas temperatures
Dayton
Type J thermocouple probe with a rounded tip and 18-inch probe length, 20 AWG wire. Temperature range -210°C to 1,200°C (-346°F to 2,193°F) with accuracy ±1.1% below 293°C and ±0.4% otherwise. Includes hose clamp for installation in gas ducts or pipes for monitoring flue or exhaust gas temperatures
Type J thermocouple probe with a rounded tip and weld junction, 6 in probe length, 20 AWG wire. Temperature range -346°F to 2,193°F (-210°C to 1,200°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise. Suitable for temperature measurement in gas-fired ovens, furnaces, and process heating systems
Dayton
Type J thermocouple probe with a rounded tip and weld junction, 6 in probe length, 20 AWG wire. Temperature range -346°F to 2,193°F (-210°C to 1,200°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise. Suitable for temperature measurement in gas-fired ovens, furnaces, and process heating systems
Type K thermocouple with rounded tip for gas applications. Accuracy ±1.1 °C or ±0.04%. Probe length 6 in, cable length 12 in with FEP jacket and stainless steel overbraid. Maximum wire gauge 16 AWG. Suitable for temperature measurement in industrial ovens, furnaces, and exhaust systems
Dayton
Type K thermocouple with rounded tip for gas applications. Accuracy ±1.1 °C or ±0.04%. Probe length 6 in, cable length 12 in with FEP jacket and stainless steel overbraid. Maximum wire gauge 16 AWG. Suitable for temperature measurement in industrial ovens, furnaces, and exhaust systems
Type J thermocouple probe with a 12-inch length and rounded tip, featuring a weld junction. Suitable for gas temperature measurement in industrial furnaces, ovens, and process heating systems. Temperature range: -210°C to 1,200°C. Accuracy: ±1.1% below 293°C, ±0.4% otherwise
Dayton
Type J thermocouple probe with a 12-inch length and rounded tip, featuring a weld junction. Suitable for gas temperature measurement in industrial furnaces, ovens, and process heating systems. Temperature range: -210°C to 1,200°C. Accuracy: ±1.1% below 293°C, ±0.4% otherwise
Type K thermocouple probe with a rounded tip and weld junction, 12 in probe length, 20 AWG wire. Temperature range -325°F to 2,280°F (-200°C to 1,250°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise. Suitable for temperature measurement in gas-fired equipment such as ovens, furnaces, and exhaust systems
Dayton
Type K thermocouple probe with a rounded tip and weld junction, 12 in probe length, 20 AWG wire. Temperature range -325°F to 2,280°F (-200°C to 1,250°C). Accuracy ±1.1% below 293°C, ±0.4% otherwise. Suitable for temperature measurement in gas-fired equipment such as ovens, furnaces, and exhaust systems
Type K thermocouple probe with a rounded tip and weld junction, 18-inch probe length. Suitable for temperature measurement in gas-fired ovens, furnaces, and exhaust systems. Temperature range -200°C to 1,250°C, accuracy ±1.1% below 293°C and ±0.4% otherwise
Dayton
Type K thermocouple probe with a rounded tip and weld junction, 18-inch probe length. Suitable for temperature measurement in gas-fired ovens, furnaces, and exhaust systems. Temperature range -200°C to 1,250°C, accuracy ±1.1% below 293°C and ±0.4% otherwise
Type K thermocouple with a 12-inch probe length and rounded tip. Designed for gas applications, it measures temperatures from -325°F to 2,280°F (-200°C to 1,250°C) with accuracy of ±1.1% below 293°C and ±0.4% otherwise. Includes a hose clamp for installation
Dayton
Type K thermocouple with a 12-inch probe length and rounded tip. Designed for gas applications, it measures temperatures from -325°F to 2,280°F (-200°C to 1,250°C) with accuracy of ±1.1% below 293°C and ±0.4% otherwise. Includes a hose clamp for installation