Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

DRAEGER Detector Tube: DRAEGER Accuro, HF, Gas Detection Tube, Hydrogen Fluoride ( HF ) - Gas Detection Tubes For Use In DRAEGER Accuro Pumps
DRAEGERGas Detection Tubes For Use In DRAEGER Accuro Pumps

DRAEGER Detector Tube: DRAEGER Accuro, HF, Gas Detection Tube, Hydrogen Fluoride ( HF )

The DRAEGER Detector Tube for the DRAEGER Accuro pump is a hydrogen fluoride (HF) gas detection tube, sold in a 10-pack (MPN 8103251). It detects hydrogen fluoride with a measurement range of 0.5 to 15 ppm and 10 to…

SKU 3G-OTH-548112

Brand
DRAEGER
Item
Detector Tube: DRAEGER Accuro, HF, Gas Detection Tube, Hydrogen Fluoride
Category
Gas Detection Tubes For Use In DRAEGER Accuro Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

DRAEGER
Manufacturer Part Number
8103251
Type
HF, Gas Detection Tube, Hydrogen Fluoride ( HF ), 10 PK
Gas Detected
Hydrogen Fluoride
Measurement Range
0.5 to 15 ppm/10 to 90 ppm
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DRAEGER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DRAEGER Detector Tube for the DRAEGER Accuro pump is a hydrogen fluoride (HF) gas detection tube, sold in a 10-pack (MPN 8103251). It detects hydrogen fluoride with a measurement range of 0.5 to 15 ppm and 10 to 90 ppm, enabling precise gas analysis in industrial environments.

Frequently Asked Questions

What is the DRAEGER Accuro HF gas detection tube used for?

The DRAEGER Accuro HF gas detection tube is used to measure hydrogen fluoride concentrations in industrial environments. It provides precise gas analysis across two ranges: 0.5 to 15 ppm and 10 to 90 ppm, supporting safety monitoring in chemical processing, metal finishing, and semiconductor manufacturing.

What are the specifications of the DRAEGER 8103251 detector tube?

The DRAEGER 8103251 detector tube detects hydrogen fluoride (HF) gas. It offers two measurement ranges: 0.5 to 15 ppm and 10 to 90 ppm. The tube is designed for use with the DRAEGER Accuro pump and is sold in a 10-pack for repeatable, reliable gas sampling.

Where to buy DRAEGER Accuro HF gas detection tubes worldwide?

3G Electric supplies DRAEGER Accuro HF gas detection tubes worldwide. As a global industrial solutions provider, we handle full logistics and customs clearance to deliver genuine DRAEGER detector tubes, including the 8103251 10-pack, to your facility anywhere in the world.

How to use the DRAEGER Accuro tube for hydrogen fluoride detection?

To use the DRAEGER Accuro HF tube, break off both tips, insert the tube into the Accuro pump, and follow the pump's stroke count for the desired range. After sampling, read the color change against the printed scale. Always refer to the manufacturer's instructions for safe handling and accurate results.

DRAEGER Products

3G Electric supplies DRAEGER gas detection tubes for use in draeger accuro pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from DRAEGER

View all DRAEGER parts
DRAEGER Detector Tube: DRAEGER Accuro, C3H6O, Gas Detection Tube, Acetone ( C3H6O ), Acetone, 10 PK (MPN 8103381). Key specifications — Gas Detected: Acetone; Measurement Range: 400 to 800 ppm.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, C3H6O, Gas Detection Tube, Acetone ( C3H6O ), Acetone, 10 PK (MPN 8103381). Key specifications — Gas Detected: Acetone; Measurement Range: 400 to 800 ppm.
DRAEGER Detector Tube: DRAEGER Accuro, CO2, Gas Detection Tube, Carbon Dioxide ( CO2 ), 10 PK (MPN 6728521). Key specifications — Gas Detected: Carbon Dioxide; Measurement Range: 100 to 3,000 ppm.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, CO2, Gas Detection Tube, Carbon Dioxide ( CO2 ), 10 PK (MPN 6728521). Key specifications — Gas Detected: Carbon Dioxide; Measurement Range: 100 to 3,000 ppm.
DRAEGER Detector Tube: DRAEGER Accuro, CCl4, Gas Detection Tube, Carbon Tetrachloride ( CCl4 ) (MPN 8103501). Key specifications — Gas Detected: Carbon Tetrachloride; Measurement Range: 0.1 to 5 ppm.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, CCl4, Gas Detection Tube, Carbon Tetrachloride ( CCl4 ) (MPN 8103501). Key specifications — Gas Detected: Carbon Tetrachloride; Measurement Range: 0.1 to 5 ppm.
DRAEGER Detector Tube: DRAEGER Accuro, CS2, Gas Detection Tube, Carbon Disulfide ( CS2 ), 10 PK (MPN 6728351). Key specifications — Gas Detected: Carbon Disulfide; Measurement Range: 5 to 60 ppm.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, CS2, Gas Detection Tube, Carbon Disulfide ( CS2 ), 10 PK (MPN 6728351). Key specifications — Gas Detected: Carbon Disulfide; Measurement Range: 5 to 60 ppm.
DRAEGER Detector Tube: DRAEGER Accuro, H2O2, Gas Detection Tube, Hydrogen Peroxide ( H2O2 ), 10 PK (MPN 8101041). Key specifications — Gas Detected: Hydrogen Peroxide; Measurement Range: 0.1 to 3 ppm/1 ppm.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, H2O2, Gas Detection Tube, Hydrogen Peroxide ( H2O2 ), 10 PK (MPN 8101041). Key specifications — Gas Detected: Hydrogen Peroxide; Measurement Range: 0.1 to 3 ppm/1 ppm.
DRAEGER Detector Tube: DRAEGER Accuro, Gas Detection Tube, Carbon Preset, Qualitative, 10 PK (MPN CH24101). Key specifications — Gas Detected: Carbon Preset; Measurement Range: Qualitative.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, Gas Detection Tube, Carbon Preset, Qualitative, 10 PK (MPN CH24101). Key specifications — Gas Detected: Carbon Preset; Measurement Range: Qualitative.
DRAEGER Detector Tube: DRAEGER Accuro, COCl2, Gas Detection Tube, Phosgene ( COCl2 ), 10 PK (MPN 8101521). Key specifications — Gas Detected: Phosgene; Measurement Range: 0.02 to 1 ppm/0.02 to 0.6 ppm.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, COCl2, Gas Detection Tube, Phosgene ( COCl2 ), 10 PK (MPN 8101521). Key specifications — Gas Detected: Phosgene; Measurement Range: 0.02 to 1 ppm/0.02 to 0.6 ppm.
DRAEGER Detector Tube: DRAEGER Accuro, H2S, Gas Detection Tube, Hydrogen Sulfide ( H2S ), 10 PK (MPN 6728041). Key specifications — Gas Detected: Hydrogen Sulfide; Measurement Range: 0.5 to 15 ppm/5 to 150 ppm.
DRAEGER
DRAEGER Detector Tube: DRAEGER Accuro, H2S, Gas Detection Tube, Hydrogen Sulfide ( H2S ), 10 PK (MPN 6728041). Key specifications — Gas Detected: Hydrogen Sulfide; Measurement Range: 0.5 to 15 ppm/5 to 150 ppm.