The DRAEGER Detector Tube for Accuro pumps is a gas detection tube designed for use with DRAEGER Accuro pumps, detecting ethylene (C2H4) with a measurement range of 0.2 to 5 ppm. Supplied in a pack of 10 (MPN…

SKU 3G-OTH-548097

Brand
DRAEGER
Item
Gas Detection Tube for Accuro Pumps
Category
Gas Detection Tubes For Use In DRAEGER Accuro Pumps
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

DRAEGER
Manufacturer Part Number
8101331
Type
C2H4, Gas Detection Tube, Ethylene ( C2H4 ), Ethylene, 10 PK
Gas Detected
Ethylene
Measurement Range
0.2 to 5 ppm

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DRAEGER Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DRAEGER Detector Tube for Accuro pumps is a gas detection tube designed for use with DRAEGER Accuro pumps, detecting ethylene (C2H4) with a measurement range of 0.2 to 5 ppm. Supplied in a pack of 10 (MPN 8101331), this tube enables precise spot-checking of ethylene concentrations in industrial environments.

Frequently Asked Questions

What is the DRAEGER Detector Tube 8101331 used for?

The DRAEGER Detector Tube 8101331 is used for spot-checking ethylene (C2H4) gas concentrations in industrial environments. It works with DRAEGER Accuro pumps to measure ethylene from 0.2 to 5 ppm, helping plant engineers and safety teams monitor air quality in applications like chemical processing or refrigeration.

What are the specifications of the DRAEGER Detector Tube 8101331?

The DRAEGER Detector Tube 8101331 detects ethylene (C2H4) gas with a measurement range of 0.2 to 5 ppm. It is supplied in a pack of 10 tubes (MPN 8101331) and is designed for use with DRAEGER Accuro pumps. This tube enables precise, on-the-spot gas detection in industrial settings.

Where to buy DRAEGER Detector Tube 8101331 worldwide?

3G Electric supplies the DRAEGER Detector Tube 8101331 worldwide. As a global industrial solutions provider, we handle full logistics and customs clearance to deliver genuine DRAEGER gas detection tubes to your facility. Contact us for availability and lead time on this ethylene detection tube.

How to use the DRAEGER Detector Tube with Accuro pump?

To use the DRAEGER Detector Tube 8101331, break off both tips of the tube, insert it into the DRAEGER Accuro pump, and follow the pump's stroke count for the specified measurement range (0.2 to 5 ppm ethylene). After sampling, read the color change against the printed scale. Always refer to the manufacturer's instructions for safe operation.

DRAEGER Products

3G Electric supplies DRAEGER gas detection tubes for use in draeger accuro pumps. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Pump Accessories Valves & Regulation Motors & Drives All Products

More from DRAEGER

View all DRAEGER parts
Gas detection tube for perchloroethylene (C2Cl4) used with DRAEGER Accuro pumps. Measures concentrations from 20 to 300 ppm and 2 to 40 ppm. Pack of 10 tubes for spot-checking air in dry-cleaning or industrial degreasing environments
DRAEGER
Gas detection tube for perchloroethylene (C2Cl4) used with DRAEGER Accuro pumps. Measures concentrations from 20 to 300 ppm and 2 to 40 ppm. Pack of 10 tubes for spot-checking air in dry-cleaning or industrial degreasing environments
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps. Each tube detects diethyl ether ((C2H5)2O) within a measurement range of 100 to 4,000 ppm and operates at temperatures up to 104°F. Suitable for industrial safety monitoring where diethyl ether may be present
DRAEGER
This 10-pack of gas detection tubes is designed for use with DRAEGER Accuro pumps. Each tube detects diethyl ether ((C2H5)2O) within a measurement range of 100 to 4,000 ppm and operates at temperatures up to 104°F. Suitable for industrial safety monitoring where diethyl ether may be present
This gas detection tube is designed for use with DRAEGER Accuro pumps to measure carbon tetrachloride (CCl4) concentrations in air. It offers two measurement ranges: 1 to 15 ppm and 10 to 50 ppm, with a maximum operating temperature of 86°F. Suitable for industrial hygiene and leak detection applications
DRAEGER
This gas detection tube is designed for use with DRAEGER Accuro pumps to measure carbon tetrachloride (CCl4) concentrations in air. It offers two measurement ranges: 1 to 15 ppm and 10 to 50 ppm, with a maximum operating temperature of 86°F. Suitable for industrial hygiene and leak detection applications
This gas detection tube is designed for use with DRAEGER Accuro pumps to detect hydrocarbon gases including propane, butane, and a 1:1 mixture. The measurement range is 0.1 to 1.3% vol for each gas. Supplied in packs of 10
DRAEGER
This gas detection tube is designed for use with DRAEGER Accuro pumps to detect hydrocarbon gases including propane, butane, and a 1:1 mixture. The measurement range is 0.1 to 1.3% vol for each gas. Supplied in packs of 10
This pack of 10 DRAEGER gas detection tubes is designed for use with DRAEGER Accuro pumps to measure toluene (C7H8) concentrations in air. The measurement range is 50 to 400 ppm. Each tube provides a single colorimetric reading for spot-check sampling in industrial hygiene or confined-space entry monitoring
DRAEGER
This pack of 10 DRAEGER gas detection tubes is designed for use with DRAEGER Accuro pumps to measure toluene (C7H8) concentrations in air. The measurement range is 50 to 400 ppm. Each tube provides a single colorimetric reading for spot-check sampling in industrial hygiene or confined-space entry monitoring
Designed for use with DRAEGER Accuro pumps, this gas detection tube measures cyanogen chloride (CNCl) concentrations in the range of 0.25 to 5 ppm. Each pack contains 10 tubes for multiple tests. Typical applications include industrial hygiene monitoring and emergency response where CNCl exposure may occur
DRAEGER
Designed for use with DRAEGER Accuro pumps, this gas detection tube measures cyanogen chloride (CNCl) concentrations in the range of 0.25 to 5 ppm. Each pack contains 10 tubes for multiple tests. Typical applications include industrial hygiene monitoring and emergency response where CNCl exposure may occur
Gas detection tube for hydrogen fluoride (HF) with a measurement range of 1.5 to 15 ppm. Designed for use with DRAEGER Accuro pumps. Supplied in a pack of 10. Suitable for on-site detection of hydrogen fluoride gas in industrial environments such as chemical processing or maintenance
DRAEGER
Gas detection tube for hydrogen fluoride (HF) with a measurement range of 1.5 to 15 ppm. Designed for use with DRAEGER Accuro pumps. Supplied in a pack of 10. Suitable for on-site detection of hydrogen fluoride gas in industrial environments such as chemical processing or maintenance
This DRAEGER gas detection tube detects trichloroethylene (C2HCl3) in air over a measurement range of 50 to 500 ppm. It is designed for use with DRAEGER Accuro pumps for on-site industrial safety monitoring. Maximum operating temperature is 104°F. Supplied as a 10-pack