Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

DUNGS MB-D(LE) 405-412 B01, One-stage mode - Gas multibloc
DungsGas multibloc

DUNGS MB-D(LE) 405-412 B01, One-stage mode

The DUNGS GasMultiBloc® MB-D(LE) 405-412 integrates filter, regulator, valves and pressure switches in one compact fitting.

SKU 3G-OTH-02921

Also listed as: MBDLE405412B01 · MB DLE 405 412 B01

Brand
Dungs
Item
MB-D
Category
Gas multibloc
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Datasheet Content

[{"filename":"mb-dle-405-412-b01_datasheet_en_214762.pdf","text":"GasMultiBloc®\n Combined regulator and\n safety shut-off valves\n Single-stage function\n\n MB-D(LE) 405 - 412 B01\n\n 7.21\n\n\n\n\n Technical description The modular system permits individual\n The DUNGS GasMultiBloc® integrates filter, solutions by using external ignition gas tap\n regulator, valves and pressure switches in in connection with separately controlled\n one compact fitting. valves, by adding a valve proving system,\n mini/maxi pressure switches, pressure\n - Dirt trap: Fine mesh-sieve limiters, limit switch V2.\n - One regulator and two valves: B01\n - Two valves are fast opening Application\n - One valve is fast opening and one valve The modular system permits individual\n is slow opening solutions in gas safety and regulator engi-\n - Solenoid valves up to 360 mbar (36 kPa) neering. Suitable for gases of families 1, 2,\n as per DIN EN 161 Class A Group 2 3 and other neutral gaseous media.\n - Sensitive setting of output pressure by\n proportional regulator as per DIN EN 88 Approvals\n Class A Group 2 EU type testing certificate as per:\n - High flow rates with low pressure drop • EU-Gas Appliances Regulation\n - DC solenoid drive interference degree N • EU-Pressure Equipment Directive\n - Main volume restrictor at valve V2 Approvals in other important gas consum-\n - Hydraulic opening delay ing countries.\n\n\n\n Edition 03.19 • Nr. 214 762\n - Flange connections with pipe threads as\n per ISO 7/1\n - Simple mounting, compact, light-\n weight\n\n\n1…5\n\fSpecifications\n\nNominal diameters MB-…405/407 B01 MB-…410/412 B01\nFlange with pipe threads as per Rp 1/2, 3/4 Rp 3/4, 1, 1 1/4\nISO 7/1 (DIN 2999) and their combinations and their combinations\n\nMax. operating pressure 360 mbar (36 kPa)\n\nOutput pressure ranges MB-… S20/S22 pa: 4 mbar (0.4 kPa) to 20 mbar (2 kPa)\n MB-… S50/S52 pa: 4 mbar (0.4 kPa) to 50 mbar (5 kPa)\n\nMedia Gases of families 1, 2, 3 and other neutral gaseous media\n\nAmbient temperature -15°C to +70°C (Do not operate MB-D below 0°C in liquid gas systems.\n Only suitable for gaseous liquid gas, liquid hydrocarbons destroy sealing ma-\n terials.)\n\nDirt trap Fine mesh-sieve, replacement only possible by dismounting the fitting.\n\nPressure switches Types GW A5, GW A2, NB A2, ÜB A2 mountable as per DIN EN 1854.\n For further information, refer to Datasheet GW A2 No. 215 183 and Datasheet\n GW A5 No. 225 901.\n\nPressure regulator Pressure regulator compensated for residual pressure, leakproof seal when\n switched off by means of valve V1 as per DIN EN 88 Class A.\n Setpoint spring permanently installed (no spring exchange possible). A vent line\n above roof is not required. Internal pulse tap provided.\n\nSolenoid valve V1 Valve as per DIN EN 161 Class A Group 2, fast closing, fast opening\n\nSolenoid valve V2 Valve as per DIN EN 161 Class A Group 2\n\n Valve V2 design\t\t Main volume restrictor\n MB fast closing fast opening without\n MB-D fast closing fast opening with\n MB-DLE fast closing slow opening with\n MB-LE fast closing slow opening without\n\nMeasuring/ignition gas connection For G 1/8 as per DIN ISO 228, refer to Pressure taps on page 4\n\nBurner pressure monitor pBr Connection downstream of valve V2, pressure switch A2 mountable on adapter laterally\n\nVoltage / frequency 50-60 Hz 220-230 V AC - 15% + 10%\n\n\nElectrical connection Plug connection as per DIN EN 175301-803\n for valves and pressure switches\n\nRating/power consumption Refer on page 4\nSwitch-on duration 100%\nDegree of protection IP 54 as per IEC 529 (EN 60529)\nRadio interference Interference degree N\n\nMaterials of gas-conveying parts Housing\t\t\t aluminium die casting\n Diaphragms, seals\t\t NBR basis, Silopren (silicone rubber)\n Solenoid drive\t\t\t steel, brass, aluminium\n\nInstallation position Solenoid vertically upright or lying horizontally as well as its intermediate positions\n\nClosed position signal contact Closed position signal contact, type K01/1 (DIN-tested), mountable on V2\n\n\n\n\n 2…5\n\f Equipment variants\n GasMultiBloc®...B01 405 B01 407 B01 410 B01 412 B01\n Single-stage function\n MB • • • •\n MB-D • • • •\n MB-DLE • • P1 • •\n Mp\n MB-LE • • L1 • •N\n Microfilter with sieve • • • •\nMp P2 Gas pressure switch\nN L2\n downstream of filter • • • •\n downstream of valve V2 on adapter laterally • • • •\n downstream of valve V2 on flange with adapter • • • •\n Pressure regulator • • • •\n Valve V1, double seat • • • •\n Valve V2, single seat • – • –\n Valve V2, double seat – • – •\n Valves controlled together • • • • S 20, S 50\n Valves controlled separately • • • • S 22, S 52\n Flange Rp 1/2 • • – –\n \t\t Rp 3/4 • • • • • = possible\n \t\t Rp 1 – – • • (•) = on request\n \t\t Rp 1 1/4 – – • • - = not possible\n\n MB-...B01 version\n\n V1 = Valve 1\n V2 = Valve 2\n 3 = Dirt trap\n 4 = Pressure switch\n 5 = Regulator\n 3 4 V1 5 V2\n\n\n\n Mounting of VPS 504 valve proving system possible\n\n\n\n Type key of MultiBloc®\n\n\n\n\n 0 = common\n 2 = separated\n\n\n 2 = 4 - 20 mbar up to 360 mbar\n 5 = 4 - 50 mbar up to 360 mbar\n\n\n\n\n 1 = two A valves for main gas + regulator\n 7 = two A valves for main gas, one A valve together\n with V1 as internal bypass around V2 + regulator\n\n\n\n\n 403 = DN 10, V2 = Single-seat valve\n 405 = DN 15, V2 = Single-seat valve\n 407 = DN 20, V2 = Double-seat valve\n 410 = DN 25, V2 = Single-seat valve\n 412 = DN 32, V2 = Double-seat valve\n 415 = DN 40, V2 = Double-seat valve\n 420 = DN 50, V2 = Double-seat valve\n\n\n without = (MB or MB-ZR)\n -D = Main volume restrictor\n -LE = adjustable opening behaviour\n -DLE = D + LE combination\n\n without = single stage\n ZR = double-stage with partial volume setting\n first stage\n\n\n 3…5\n\f Dimensions [mm]\n\n\n\n f\n…

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dungs Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DUNGS GasMultiBloc® MB-D(LE) 405-412 integrates filter, regulator, valves and pressure switches in one compact fitting.

Frequently Asked Questions

What is the DUNGS MB-D(LE) 405-412 B01 used for?

The DUNGS GasMultiBloc® MB-D(LE) 405-412 B01 is a single-stage gas multibloc used for gas safety and regulation in industrial burners and boilers. It integrates a filter, regulator, two safety shut-off valves, and pressure switches into one compact fitting, suitable for gases of families 1, 2, and 3.

What are the specifications of the DUNGS MB-D(LE) 405-412 B01?

The DUNGS MB-D(LE) 405-412 B01 has a maximum operating pressure of 360 mbar (36 kPa) and nominal diameters of Rp 1/2 to 1 1/4. Output pressure ranges are 4 mbar to 20 mbar (S20/S22) or 4 mbar to 50 mbar (S50/S52). Ambient temperature range is -15°C to +70°C. It features fast-opening solenoid valves per DIN EN 161 Class A Group 2.

Where to buy the DUNGS MB-D(LE) 405-412 B01 in Singapore?

You can source the DUNGS MB-D(LE) 405-412 B01 from 3G Electric in Singapore. We supply genuine Dungs gas multiblocs and handle logistics, customs clearance, and delivery to your facility. Contact us for pricing and lead time on this single-stage gas safety component.

How to install the DUNGS MB-D(LE) 405-412 B01?

Install the DUNGS MB-D(LE) 405-412 B01 by mounting it with flange connections per ISO 7/1 pipe threads. Ensure the gas supply is off and the ambient temperature is within -15°C to +70°C. Do not operate below 0°C in liquid gas systems. Use a qualified technician to connect the pressure switches and verify the regulator setting.

Used in

Common applications for Dungs
Industrial steam boilers — MB-ZRDLE MultiBloc on modulating gas-fired plant
Hospital and hotel plant rooms — MB-D series for two-stage commercial burners
Food-industry ovens and dryers — DMV butterfly valves on high-turndown modulating lines
Petrochemical gas-train skid assemblies — FRS / FRSBV regulators with GW pressure switches
Retrofit drop-in replacements for older Dungs MB assemblies on existing Weishaupt / Riello burners

Dungs Products

3G Electric supplies Dungs gas multibloc. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
GAS P 450/M CE-LX TL EL EVO (1) Cl. 3. | Variant: metano | Subgroup: Burner with electronic cam
FBR
GAS P 450/M CE-LX TL EL EVO (1) Cl. 3. | Variant: metano | Subgroup: Burner with electronic cam
FBR
FBR
GAS P 550/M CE-LX TL EL EVO (1) Cl. 3 | Variant: metano | Subgroup: Burner with electronic cam
FBR
FBR
GAS P 350/M CE-LX TL EL EVO (1) Cl. 3 | Variant: metano | Subgroup: Burner with electronic cam
GAS P 250/M CE-LX TL MEC Cl. 3 | Variant: metano | Subgroup: Burner with mechanical cam
FBR
GAS P 250/M CE-LX TL MEC Cl. 3 | Variant: metano | Subgroup: Burner with mechanical cam
BURNER GAS X5/MF TL EL VC LPG + GAS TRAIN D1"-S
FBR
BURNER GAS X5/MF TL EL VC LPG + GAS TRAIN D1"-S
GAS P 130/M CE-LX4 TL EVO Cl. 4 | Variant: metano | Subgroup: Burner
FBR
GAS P 130/M CE-LX4 TL EVO Cl. 4 | Variant: metano | Subgroup: Burner

More from Dungs

View all Dungs parts
DUNGS MB-VEF 407-412 B01, Gas-air-ratio control
Dungs
DUNGS MB-VEF 407-412 B01, Gas-air-ratio control
DUNGS MB-ZRD(LE) 407-412 B07, Integrated bypass valve
Dungs
DUNGS MB-ZRD(LE) 407-412 B07, Integrated bypass valve
DUNGS MB-ZRD(LE) 415-420 B01, Two-stage function
Dungs
DUNGS MB-ZRD(LE) 415-420 B01, Two-stage function
DUNGS MBC-...-VEF, Infinitely variable air/gas ratio control mode
Dungs
DUNGS MBC-...-VEF, Infinitely variable air/gas ratio control mode
DUNGS MBC-...-SE, Combined servo pressure regulator and safety shut-off valves
Dungs
DUNGS MBC-...-SE, Combined servo pressure regulator and safety shut-off valves
DUNGS MB-D(LE) 415-420 B01, One-stage mode
Dungs
DUNGS MB-D(LE) 415-420 B01, One-stage mode
DUNGS MBC-WND - DUNGS WhirlWind System®
Dungs
DUNGS MBC-WND - DUNGS WhirlWind System®
DUNGS MBC-300/700/1200-SE/N, safety shut-off valves
Dungs
DUNGS MBC-300/700/1200-SE/N, safety shut-off valves