Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

Dwyer Pressure Transmitter: 0 psi to 15 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT - Pressure Transmitters with Cable & Wire Leads
DwyerPressure Transmitters with Cable & Wire Leads

Dwyer Pressure Transmitter: 0 psi to 15 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT

The Dwyer Series 626 Pressure Transmitter (MPN 626-07-GH-P1-E1-S1) is a 0 psi to 15 psi pressure transmitter with cable and wire leads, offering a 4 to 20mA DC output. It features an accuracy of ±0.25%, an IP66 and…

SKU 3G-OTH-176402

Also listed as: 62607GHP1E1S1 · 626 07 GH P1 E1 S1

Brand
Dwyer
Item
Pressure Transmitter: 0 psi to 15 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT
Category
Pressure Transmitters with Cable & Wire Leads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

Dwyer
Manufacturer Part Number
626-07-GH-P1-E1-S1
Series
626
Type
Cable, IP66 /4X
DC
4 to 20mA
Output
4 to 20mA DC
Accuracy
±0.25%
Cable Lg
3 ft
Male NPT
1/4 in
IP Rating
IP66
NEMA Rating
4X
Overpressure
150 psig
Housing Material
Stainless Steel
Electrical Connections
Cable
Process Connection Type
NPT
Process Connection Gender
Male
Calibration Certificate Included
No NIST-Traceable Calibration Certificate Included

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

Dwyer Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The Dwyer Series 626 Pressure Transmitter (MPN 626-07-GH-P1-E1-S1) is a 0 psi to 15 psi pressure transmitter with cable and wire leads, offering a 4 to 20mA DC output. It features an accuracy of ±0.25%, an IP66 and NEMA 4X rating, a stainless steel housing, a 1/4 in Male NPT process connection, and an overpressure rating of 150 psig.

Frequently Asked Questions

What is the Dwyer 626-07-GH-P1-E1-S1 pressure transmitter used for?

The Dwyer Series 626 pressure transmitter measures 0 psi to 15 psi and outputs a 4 to 20mA DC signal. It is used in industrial process control, HVAC, and pump monitoring applications where reliable pressure sensing in harsh environments is required.

What are the specifications of the Dwyer 626-07-GH-P1-E1-S1?

This Dwyer transmitter has an accuracy of ±0.25%, a 4 to 20mA DC output, a 1/4 in Male NPT connection, and a stainless steel housing. It is rated IP66 and NEMA 4X, with an overpressure limit of 150 psig and a 3 ft cable.

Where to buy the Dwyer 626-07-GH-P1-E1-S1 pressure transmitter worldwide?

3G Electric supplies the Dwyer 626-07-GH-P1-E1-S1 pressure transmitter worldwide. As a global industrial solutions provider, we handle full logistics, customs clearance, and delivery to your facility, ensuring you get the right Dwyer transmitter for your application.

How to install the Dwyer 626-07-GH-P1-E1-S1 pressure transmitter?

Install the Dwyer 626 transmitter by threading the 1/4 in Male NPT connection into a compatible process port. Use appropriate sealant on the threads. Connect the cable to a 4 to 20mA DC input, ensuring the supply voltage meets the transmitter's requirements. Avoid overpressure beyond 150 psig.

Used in

Common applications for Dwyer
Combustion air-filter monitoring — Magnehelic Series 2000 on burner air-intake filter banks
Clean-room and pharmaceutical pressurisation — Magnehelic / Capsuhelic differential-pressure gauges
HVAC fan-discharge static pressure — Mark II inclined-vertical manometers on AHU test points
Filter-blockage alarms — Photohelic Series 3000 combined gauge/switch on air-handling units
BMS-integrated pressure monitoring — Digihelic DH3 with 4–20 mA output for building management

Dwyer Products

3G Electric supplies Dwyer pressure transmitters with cable & wire leads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Pressure Transmitter: 0 psi to 100 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X (MPN 626-10-GH-P1-E1-S1)
Dwyer
Pressure Transmitter: 0 psi to 100 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X (MPN 626-10-GH-P1-E1-S1)
Pressure Transmitter: 0 psi to 15 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X, 3 ft Cable Lg (MPN 628-07-GH-P1-E1-S1)
Dwyer
Pressure Transmitter: 0 psi to 15 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X, 3 ft Cable Lg (MPN 628-07-GH-P1-E1-S1)
Pressure Transmitter: 0 psi to 150 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X (MPN 628-11-GH-P1-E1-S1)
Dwyer
Pressure Transmitter: 0 psi to 150 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X (MPN 628-11-GH-P1-E1-S1)
Pressure Transmitter: 0 psi to 50 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X, 3 ft Cable Lg (MPN 628-09-GH-P1-E1-S1)
Dwyer
Pressure Transmitter: 0 psi to 50 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X, 3 ft Cable Lg (MPN 628-09-GH-P1-E1-S1)
Pressure Transmitter: 0 psi to 300 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X (MPN 626-13-GH-P1-E1-S1)
Dwyer
Pressure Transmitter: 0 psi to 300 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X (MPN 626-13-GH-P1-E1-S1)
Pressure Transmitter: 0 psi to 30 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X, 3 ft Cable Lg (MPN 628-08-GH-P1-E1-S1)
Dwyer
Pressure Transmitter: 0 psi to 30 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X, 3 ft Cable Lg (MPN 628-08-GH-P1-E1-S1)

More from Dwyer

View all Dwyer parts
The Dwyer Series 628 pressure transmitter measures pressure from 0 to 200 psi with ±1% accuracy and outputs a 4-20 mA DC signal. It features a stainless steel housing, 1/4 in Male NPT process connection, cable electrical connection, and IP66/NEMA 4X protection. Suitable for industrial process control, HVAC, and fluid monitoring applications
Dwyer
The Dwyer Series 628 pressure transmitter measures pressure from 0 to 200 psi with ±1% accuracy and outputs a 4-20 mA DC signal. It features a stainless steel housing, 1/4 in Male NPT process connection, cable electrical connection, and IP66/NEMA 4X protection. Suitable for industrial process control, HVAC, and fluid monitoring applications
Stainless steel pressure transmitter with 4-20 mA DC output and cable electrical connection. Features 1/4" male NPT process connection, ±0.25% accuracy, and 750 psig overpressure rating. Rated IP66 and NEMA 4X for environmental protection. Suitable for monitoring gases or liquids in industrial systems
Dwyer
Stainless steel pressure transmitter with 4-20 mA DC output and cable electrical connection. Features 1/4" male NPT process connection, ±0.25% accuracy, and 750 psig overpressure rating. Rated IP66 and NEMA 4X for environmental protection. Suitable for monitoring gases or liquids in industrial systems
Stainless steel pressure transmitter with 0 to 200 psi range and 4-20mA DC output. Accuracy ±0.25%, overpressure 1,000 psig. Cable electrical connection with 1/4 in male NPT process connection. IP66 and NEMA 4X rated for use in industrial HVAC, pump control, and process monitoring applications
Dwyer
Stainless steel pressure transmitter with 0 to 200 psi range and 4-20mA DC output. Accuracy ±0.25%, overpressure 1,000 psig. Cable electrical connection with 1/4 in male NPT process connection. IP66 and NEMA 4X rated for use in industrial HVAC, pump control, and process monitoring applications
Pressure Transmitter: 0 psi to 30 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X, 3 ft Cable Lg (MPN 626-08-GH-P1-E1-S1)
Dwyer
Pressure Transmitter: 0 psi to 30 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X, 3 ft Cable Lg (MPN 626-08-GH-P1-E1-S1)
Pressure Transmitter: 0 psi to 50 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X, 3 ft Cable Lg (MPN 626-09-GH-P1-E1-S1)
Dwyer
Pressure Transmitter: 0 psi to 50 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X, 3 ft Cable Lg (MPN 626-09-GH-P1-E1-S1)
Pressure Transmitter: 0 psi to 500 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X (MPN 628-14-GH-P1-E1-S1)
Dwyer
Pressure Transmitter: 0 psi to 500 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X (MPN 628-14-GH-P1-E1-S1)
Pressure Transmitter: 0 psi to 100 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X (MPN 628-10-GH-P1-E1-S1)
Dwyer
Pressure Transmitter: 0 psi to 100 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X (MPN 628-10-GH-P1-E1-S1)
Pressure Transmitter: 0 psi to 300 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X (MPN 628-13-GH-P1-E1-S1)
Dwyer
Pressure Transmitter: 0 psi to 300 psi, 4 to 20mA DC, Cable, 1/4 in Male NPT, IP66 /4X (MPN 628-13-GH-P1-E1-S1)