Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

DYNASONICS Ultrasonic Flow Transducer and Meter: Flow Meter, Ultrasonic, Clamp-On - Portable Clamp-On Ultrasonic Flowmeters for Water
DYNASONICSPortable Clamp-On Ultrasonic Flowmeters for Water

DYNASONICS Ultrasonic Flow Transducer and Meter: Flow Meter, Ultrasonic, Clamp-On

The DYNASONICS D5-C-E2-AD-S-A-K-E-D is a portable clamp-on ultrasonic flow meter for water, offering an accuracy of +/- 0.5%. It operates on a maximum voltage of 240V AC and accommodates pipe sizes from 1/2 to 12 inches.

SKU 3G-OTH-89648

Brand
DYNASONICS
Item
Ultrasonic Flow Transducer and Meter: Flow Meter, Ultrasonic, Clamp-On
Category
Portable Clamp-On Ultrasonic Flowmeters for Water
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineer
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Technical Specifications

DYNASONICS
Manufacturer Part Number
D5-C-E2-AD-S-A-K-E-D
Type
Ultrasonic, Clamp-On, Aluminum
AC
240V
Accuracy
+/- 0.5%
For Pipe Size
1/2 to 12 in
Voltage (Maximum)
240V AC
View Full Spec Sheet

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

DYNASONICS Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The DYNASONICS D5-C-E2-AD-S-A-K-E-D is a portable clamp-on ultrasonic flow meter for water, offering an accuracy of +/- 0.5%. It operates on a maximum voltage of 240V AC and accommodates pipe sizes from 1/2 to 12 inches.

Frequently Asked Questions

What is the DYNASONICS D5-C-E2-AD-S-A-K-E-D ultrasonic flow meter used for?

This portable clamp-on ultrasonic flow meter measures water flow rate in pipes from 1/2 to 12 inches without cutting the line. It is used for temporary or permanent flow monitoring in water treatment, HVAC, and industrial process applications where non-invasive measurement is required.

What are the specifications of the DYNASONICS D5-C-E2-AD-S-A-K-E-D?

The DYNASONICS D5-C-E2-AD-S-A-K-E-D is a portable clamp-on ultrasonic flow meter with an accuracy of +/- 0.5%. It operates on a maximum voltage of 240V AC and fits pipe sizes from 1/2 to 12 inches. The aluminum housing is designed for durability in industrial environments.

Where to buy the DYNASONICS D5-C-E2-AD-S-A-K-E-D worldwide?

3G Electric supplies the DYNASONICS D5-C-E2-AD-S-A-K-E-D portable clamp-on ultrasonic flow meter to customers worldwide. We handle full logistics, customs clearance, and delivery to your site. Contact us for a quote and lead time on this precision flow measurement instrument.

How to install a clamp-on ultrasonic flow meter like the DYNASONICS D5?

Clean the pipe surface at the measurement point, apply acoustic coupling gel, and mount the transducer clamps securely per the manufacturer's spacing guidelines. Connect the meter to a 240V AC power source and configure the pipe size and material in the display menu. Verify zero flow before taking readings.

Used in

Common applications for DYNASONICS
Water and wastewater treatment — DYNASONICS D5-C portable clamp-on flowmeters for non-invasive flow monitoring in large-diameter pipes up to 48 inches.
Chemical processing — DYNASONICS Doppler flow transducers (e.g., 7HU46) for measuring flow of slurries and aerated chemical solutions with ±2% accuracy.
HVAC systems — DYNASONICS transit-time flowmeters for chilled water and condenser water flow measurement in building energy management.
Oil and gas — DYNASONICS DTTR-020-N000-N transducers for custody transfer or leak detection on pipelines from 2 to 98 inches.
Food and beverage — DYNASONICS clamp-on ultrasonic flowmeters for sanitary flow measurement of clean liquids without contact or contamination.
Mining and minerals — DYNASONICS Doppler transducers for monitoring abrasive slurry flows in mineral processing plants.

DYNASONICS Products

3G Electric supplies DYNASONICS portable clamp-on ultrasonic flowmeters for water. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Similar products

Matched by specification & description
DYNASONICS Transducer: 1 in to 1 in Pipe Size, -40°F to 185°F, 6 sec to 60 sec, DT94-020-N000-N, LCD. Key specifications — Brand: DYNASONICS.
DYNASONICS
DYNASONICS Transducer: 1 in to 1 in Pipe Size, -40°F to 185°F, 6 sec to 60 sec, DT94-020-N000-N, LCD. Key specifications — Brand: DYNASONICS.
DYNASONICS Ultrasonic Meter: +/-2% Full Scale Flow Accuracy, 0.15 fps Flow Measured - Min, LCD (MPN DDFXD2-ANNA-NN). Key specifications — Manufacturer Part Number: DDFXD2-ANNA-NN; Digital Display Screen Type: LCD; Flow Accuracy: +/-2% Full Scale; Brand: DYNASONICS.
DYNASONICS
DYNASONICS Ultrasonic Meter: +/-2% Full Scale Flow Accuracy, 0.15 fps Flow Measured - Min, LCD (MPN DDFXD2-ANNA-NN). Key specifications — Manufacturer Part Number: DDFXD2-ANNA-NN; Digital Display Screen Type: LCD; Flow Accuracy: +/-2% Full Scale; Brand: DYNASONICS.
DYNASONICS Transducer: 0.25 in to 1 in Pipe Size, -40°F to 185°F, 6 sec to 60 sec, DT95-020-N000-N. Key specifications — Brand: DYNASONICS.
DYNASONICS
DYNASONICS Transducer: 0.25 in to 1 in Pipe Size, -40°F to 185°F, 6 sec to 60 sec, DT95-020-N000-N. Key specifications — Brand: DYNASONICS.
DYNASONICS Transducer: Transducers, Water, 2 to 98 in For Pipe Size, 2 in Connection Size, PBT (MPN DTTR-020-N000-N). Key specifications — Brand: DYNASONICS; Accuracy: +/-1%; Output Type: 4-20 mA.
DYNASONICS
DYNASONICS Transducer: Transducers, Water, 2 to 98 in For Pipe Size, 2 in Connection Size, PBT (MPN DTTR-020-N000-N). Key specifications — Brand: DYNASONICS; Accuracy: +/-1%; Output Type: 4-20 mA.
DYNASONICS Ultrasonic Meter: +/-2% Full Scale Flow Accuracy, 0.15 fps Flow Measured - Min, LCD (MPN DDFXD2-ENNA-NN). Key specifications — Manufacturer Part Number: DDFXD2-ENNA-NN; Digital Display Screen Type: LCD; Flow Accuracy: +/-2% Full Scale; Brand: DYNASONICS.
DYNASONICS
DYNASONICS Ultrasonic Meter: +/-2% Full Scale Flow Accuracy, 0.15 fps Flow Measured - Min, LCD (MPN DDFXD2-ENNA-NN). Key specifications — Manufacturer Part Number: DDFXD2-ENNA-NN; Digital Display Screen Type: LCD; Flow Accuracy: +/-2% Full Scale; Brand: DYNASONICS.
DYNASONICS Ultrasonic Flow Detector: +/-2% Full Scale Flow Accuracy, 0.15 fps Flow Measured - Min (MPN 7HU46). Key specifications — Manufacturer Part Number: 7HU46; Compatible with Grainger Part Number: 5XPN3; Digital Display Screen Type: LCD; Flow Accuracy: +/-2% Full Scale; Brand: DYNASONICS.
DYNASONICS
DYNASONICS Ultrasonic Flow Detector: +/-2% Full Scale Flow Accuracy, 0.15 fps Flow Measured - Min (MPN 7HU46). Key specifications — Manufacturer Part Number: 7HU46; Compatible with Grainger Part Number: 5XPN3; Digital Display Screen Type: LCD; Flow Accuracy: +/-2% Full Scale; Brand: DYNASONICS.

More from DYNASONICS

View all DYNASONICS parts
DYNASONICS Ultrasonic Flow Transducer and Meter: Flow Meter, Ultrasonic, Clamp-On, Aluminum, 240V AC (MPN D5-C-B2-AD-S-A-K-E-D). Key specifications — Brand: DYNASONICS; Voltage (Maximum): 240V AC; Accuracy: +/- 0.5%; For Pipe Size: 1/2 to 12 in.
DYNASONICS
DYNASONICS Ultrasonic Flow Transducer and Meter: Flow Meter, Ultrasonic, Clamp-On, Aluminum, 240V AC (MPN D5-C-B2-AD-S-A-K-E-D). Key specifications — Brand: DYNASONICS; Voltage (Maximum): 240V AC; Accuracy: +/- 0.5%; For Pipe Size: 1/2 to 12 in.
DYNASONICS Ultrasonic Flow Transducer and Meter: Flow Meter, Ultrasonic, Clamp-On, Aluminum, 240V AC (MPN D5-C-T2-AD-S-A-K-E-D). Key specifications — Brand: DYNASONICS; Voltage (Maximum): 240V AC; Accuracy: +/- 0.5%; For Pipe Size: 1/2 to 48 in.
DYNASONICS
DYNASONICS Ultrasonic Flow Transducer and Meter: Flow Meter, Ultrasonic, Clamp-On, Aluminum, 240V AC (MPN D5-C-T2-AD-S-A-K-E-D). Key specifications — Brand: DYNASONICS; Voltage (Maximum): 240V AC; Accuracy: +/- 0.5%; For Pipe Size: 1/2 to 48 in.
DYNASONICS Ultrasonic Flow Transducer and Meter: Flow Meter, Ultrasonic, Clamp-On, Aluminum, 240V AC (MPN D5-C-H2-AD-S-A-K-E-D). Key specifications — Brand: DYNASONICS; Voltage (Maximum): 240V AC; Accuracy: +/- 0.5%; For Pipe Size: 1/2 to 12 in.
DYNASONICS
DYNASONICS Ultrasonic Flow Transducer and Meter: Flow Meter, Ultrasonic, Clamp-On, Aluminum, 240V AC (MPN D5-C-H2-AD-S-A-K-E-D). Key specifications — Brand: DYNASONICS; Voltage (Maximum): 240V AC; Accuracy: +/- 0.5%; For Pipe Size: 1/2 to 12 in.
DYNASONICS Flow Meter: Flow Meter, Ultrasonic, Clamp-On, Water-Like Liquids, 48 in Connection Size (MPN D5-C-F2-AD-S-A-2-E-D). Key specifications — Brand: DYNASONICS; Voltage (Maximum): 240V AC; Accuracy: +/- 0.5%; For Pipe Size: 1/1 to 48 in.
DYNASONICS
DYNASONICS Flow Meter: Flow Meter, Ultrasonic, Clamp-On, Water-Like Liquids, 48 in Connection Size (MPN D5-C-F2-AD-S-A-2-E-D). Key specifications — Brand: DYNASONICS; Voltage (Maximum): 240V AC; Accuracy: +/- 0.5%; For Pipe Size: 1/1 to 48 in.