Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

EATON AN19AN0B5E020 Non-Reversing Starter with Electronic Overload - Non-Reversing Starters with Electronic Overloads
EATONNon-Reversing Starters with Electronic Overloads

EATON AN19AN0B5E020 Non-Reversing Starter with Electronic Overload

The EATON NEMA Magnetic Motor Starter is a non-reversing starter with electronic overloads, featuring three poles, NEMA Size 00, and a 9 A rating. It operates with a 220/240V AC coil voltage and includes a 1NO…

SKU 3G-OTH-44143

Brand
EATON
Item
AN19AN0B5E020 Non-Reversing Starter with Electronic Overload
Category
Non-Reversing Starters with Electronic Overloads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

EATON
Manufacturer Part Number
AN19AN0B5E020
Type
NEMA Size 00, 9 A
Phase
Three
Poles
3
AC Coil
240V
Operator
None
Coil Voltage
220/240V AC
Operator Controls
None
Signaling Features
Pilot Light
Auxiliary Contact Form
1NO
Thermal Units Required
None (Not Applicable to Electronic Overloads)
Auxiliary Contacts Included
1NO

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

EATON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The EATON NEMA Magnetic Motor Starter is a non-reversing starter with electronic overloads, featuring three poles, NEMA Size 00, and a 9 A rating. It operates with a 220/240V AC coil voltage and includes a 1NO auxiliary contact and a pilot light for signaling. This three-phase starter has no operator or operator controls, and thermal units are not applicable due to the electronic overload design.

Frequently Asked Questions

What is the EATON NEMA Magnetic Motor Starter used for?

The EATON NEMA Magnetic Motor Starter is used to start and stop three-phase motors in industrial applications such as pumps, fans, and conveyors. Its non-reversing design and electronic overload protection make it suitable for constant-direction machinery where reliable motor control and overcurrent protection are required.

What are the specifications of the EATON AN19AN0B5E020 motor starter?

The EATON AN19AN0B5E020 is a non-reversing, three-pole NEMA Size 00 starter rated at 9 A. It has a 220/240V AC coil voltage, includes one normally open auxiliary contact and a pilot light. Electronic overloads eliminate the need for thermal units. It is a three-phase unit with no operator controls.

Where to buy the EATON AN19AN0B5E020 motor starter worldwide?

You can source the EATON AN19AN0B5E020 motor starter through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations. Contact us for availability and lead time; we supply genuine EATON components to industrial buyers internationally.

How to select the correct EATON NEMA motor starter for a motor?

Select the EATON NEMA motor starter by matching the motor's full-load current (FLC) to the starter's ampere rating—here 9 A for NEMA Size 00. Verify the coil voltage matches your control circuit (220/240V AC). Ensure the starter's pole count and phase (three) align with the motor. Electronic overloads simplify setup by eliminating thermal unit selection.

Used in

Common applications for EATON
Industrial control panels — Eaton M22 flush push buttons for momentary machine start/stop commands
Motor control centers — Eaton NEMA reversing starters with electronic overloads for conveyor belt direction control
HVAC systems — Eaton definite purpose starters with thermal overloads for compressor and fan motor protection
Process automation — Eaton SL7 tower lights with IP66 bases for visual status indication in wet environments
Machine tool signaling — Eaton 10250T LED pilot lights with push-to-test for operator panel status lamps
Access control — Eaton M22 keyed selector switches for equipment mode selection in secured areas

EATON Products

3G Electric supplies EATON non-reversing starters with electronic overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Three-pole non-reversing motor starter with electronic overload protection, NEMA Size 00, rated 9 A. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for signaling. No thermal units required. Suitable for starting and stopping three-phase motors in applications such as pumps, fans, conveyors, and compressors
EATON
Three-pole non-reversing motor starter with electronic overload protection, NEMA Size 00, rated 9 A. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for signaling. No thermal units required. Suitable for starting and stopping three-phase motors in applications such as pumps, fans, conveyors, and compressors
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 00, 9 A, 240V AC Coil (MPN AN19AN0B5E005)
EATON
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 00, 9 A, 240V AC Coil (MPN AN19AN0B5E005)
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 00, 9 A, 480V AC Coil (MPN AN19AN0C5E005)
EATON
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 00, 9 A, 480V AC Coil (MPN AN19AN0C5E005)
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 00, 9 A, 480V AC Coil (MPN AN19AN0C5E020)
EATON
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 00, 9 A, 480V AC Coil (MPN AN19AN0C5E020)
Three-pole non-reversing motor starter with electronic overload protection. NEMA Size 00, rated 9 A. Coil voltage 440/480V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase motors in industrial applications such as conveyors, pumps, and compressors
EATON
Three-pole non-reversing motor starter with electronic overload protection. NEMA Size 00, rated 9 A. Coil voltage 440/480V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase motors in industrial applications such as conveyors, pumps, and compressors
Three-pole non-reversing motor starter with electronic overload protection, NEMA Size 00, rated 9 A. Includes a 24V AC coil, one normally open auxiliary contact, and a pilot light for signaling. No thermal units required. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and fans
EATON
Three-pole non-reversing motor starter with electronic overload protection, NEMA Size 00, rated 9 A. Includes a 24V AC coil, one normally open auxiliary contact, and a pilot light for signaling. No thermal units required. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and fans

More from EATON

View all EATON parts
Three-pole non-reversing motor starter with electronic overload protection, rated 270 A at NEMA Size 5. Coil voltage 440/480V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and protecting three-phase motors in industrial applications
EATON
Three-pole non-reversing motor starter with electronic overload protection, rated 270 A at NEMA Size 5. Coil voltage 440/480V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and protecting three-phase motors in industrial applications
Three-phase non-reversing magnetic motor starter with electronic overload protection. NEMA Size 0, 18 A rating, 3 poles, 440/480V AC coil. Includes one normally open auxiliary contact and a pilot light. No thermal units required. Suitable for starting and stopping three-phase AC motors in applications such as conveyors, pumps, and compressors
EATON
Three-phase non-reversing magnetic motor starter with electronic overload protection. NEMA Size 0, 18 A rating, 3 poles, 440/480V AC coil. Includes one normally open auxiliary contact and a pilot light. No thermal units required. Suitable for starting and stopping three-phase AC motors in applications such as conveyors, pumps, and compressors
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated 45 A at NEMA Size 2. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase AC motors in applications such as pumps, fans, and conveyors
EATON
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated 45 A at NEMA Size 2. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase AC motors in applications such as pumps, fans, and conveyors
Three-pole, non-reversing motor starter with electronic overload protection, rated 27 A at NEMA Size 1. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. No thermal units required. Suitable for starting and stopping three-phase motors in industrial applications
EATON
Three-pole, non-reversing motor starter with electronic overload protection, rated 27 A at NEMA Size 1. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. No thermal units required. Suitable for starting and stopping three-phase motors in industrial applications
This EATON non-reversing starter with electronic overload is a NEMA Size 00 unit rated 9 A for three-phase motors. It features a 208V AC coil, three poles, a pilot light, and one normally open auxiliary contact. The electronic overload eliminates the need for separate thermal units. Typical applications include controlling constant-speed machinery such as pumps, fans, and conveyors
EATON
This EATON non-reversing starter with electronic overload is a NEMA Size 00 unit rated 9 A for three-phase motors. It features a 208V AC coil, three poles, a pilot light, and one normally open auxiliary contact. The electronic overload eliminates the need for separate thermal units. Typical applications include controlling constant-speed machinery such as pumps, fans, and conveyors
Three-pole NEMA Size 2 non-reversing motor starter rated 45 A with electronic overload protection. Coil voltage 110/120V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase motors in industrial applications such as pumps, fans, and conveyors
EATON
Three-pole NEMA Size 2 non-reversing motor starter rated 45 A with electronic overload protection. Coil voltage 110/120V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase motors in industrial applications such as pumps, fans, and conveyors
Three-pole NEMA Size 1 non-reversing motor starter rated 27 A with 440/480V AC coil. Includes one normally open auxiliary contact and a pilot light for signaling. Electronic overload protection eliminates need for thermal units. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and fans
EATON
Three-pole NEMA Size 1 non-reversing motor starter rated 27 A with 440/480V AC coil. Includes one normally open auxiliary contact and a pilot light for signaling. Electronic overload protection eliminates need for thermal units. Suitable for starting and stopping three-phase motors in applications such as conveyors, pumps, and fans
Non-reversing starter with electronic overload protection, rated 32 A and 600V AC. Features 3 poles, a selector switch, and a 55 mm D frame width. No thermal units required. Suitable for starting and protecting three-phase motors in applications such as conveyors, pumps, and fans
EATON
Non-reversing starter with electronic overload protection, rated 32 A and 600V AC. Features 3 poles, a selector switch, and a 55 mm D frame width. No thermal units required. Suitable for starting and protecting three-phase motors in applications such as conveyors, pumps, and fans