Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

EATON AN19GN0C5E020 Non-Reversing Starter with Electronic Overload - Non-Reversing Starters with Electronic Overloads
EATONNon-Reversing Starters with Electronic Overloads

EATON AN19GN0C5E020 Non-Reversing Starter with Electronic Overload

The EATON NEMA Magnetic Motor Starter is a non-reversing starter with electronic overloads, designed for three-phase applications. This NEMA Size 2 unit features a 45 A rating and a 440/480V AC coil voltage, with a…

SKU 3G-OTH-42976

Brand
EATON
Item
AN19GN0C5E020 Non-Reversing Starter with Electronic Overload
Category
Non-Reversing Starters with Electronic Overloads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

EATON
Manufacturer Part Number
AN19GN0C5E020
Type
NEMA Size 2, 45 A
Phase
Three
Poles
3
AC Coil
480V
Operator
None
Coil Voltage
440/480V AC
Operator Controls
None
Signaling Features
Pilot Light
Auxiliary Contact Form
1NO
Thermal Units Required
None (Not Applicable to Electronic Overloads)
Auxiliary Contacts Included
1NO

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

EATON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The EATON NEMA Magnetic Motor Starter is a non-reversing starter with electronic overloads, designed for three-phase applications. This NEMA Size 2 unit features a 45 A rating and a 440/480V AC coil voltage, with a 1NO auxiliary contact and a pilot light for signaling. It requires no thermal units, as the electronic overload eliminates the need for them.

Frequently Asked Questions

What is the EATON NEMA Magnetic Motor Starter used for?

The EATON NEMA Magnetic Motor Starter is used to start and stop three-phase motors in industrial applications such as pumps, fans, and conveyors. Its electronic overload protects the motor from damage without requiring thermal units, making it suitable for continuous-duty operations.

What are the specifications of the EATON AN19GN0C5E020 motor starter?

The EATON AN19GN0C5E020 is a NEMA Size 2, non-reversing starter rated 45 A with a 440/480V AC coil voltage. It includes one normally open auxiliary contact and a pilot light for signaling. The electronic overload eliminates the need for thermal units, simplifying setup.

Where to buy the EATON AN19GN0C5E020 motor starter worldwide?

You can source the EATON AN19GN0C5E020 motor starter through 3G Electric, a global industrial equipment distributor. We handle full logistics, customs clearance, and delivery to worldwide destinations, ensuring the product reaches your facility reliably.

How to install the EATON NEMA Size 2 motor starter?

Mount the starter on a flat surface, connect three-phase power to the line terminals, and wire the motor to the load terminals. Set the electronic overload dial to the motor's full-load current. Ensure the 440/480V AC coil voltage matches your control circuit before energizing.

Used in

Common applications for EATON
Industrial control panels — Eaton M22 flush push buttons for momentary machine start/stop commands
Motor control centers — Eaton NEMA reversing starters with electronic overloads for conveyor belt direction control
HVAC systems — Eaton definite purpose starters with thermal overloads for compressor and fan motor protection
Process automation — Eaton SL7 tower lights with IP66 bases for visual status indication in wet environments
Machine tool signaling — Eaton 10250T LED pilot lights with push-to-test for operator panel status lamps
Access control — Eaton M22 keyed selector switches for equipment mode selection in secured areas

EATON Products

3G Electric supplies EATON non-reversing starters with electronic overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 480V AC Coil (MPN AN19GN0C5E045)
EATON
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 480V AC Coil (MPN AN19GN0C5E045)
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 480V AC Coil (MPN AN19GN0C5E005)
EATON
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 2, 45 A, 480V AC Coil (MPN AN19GN0C5E005)
Three-pole NEMA Size 2 non-reversing motor starter rated 45 A with 220/240V AC coil. Includes electronic overload protection (no thermal units required), one normally open auxiliary contact, and a pilot light. Suitable for starting and stopping three-phase motors in industrial applications such as pumps, fans, and conveyors
EATON
Three-pole NEMA Size 2 non-reversing motor starter rated 45 A with 220/240V AC coil. Includes electronic overload protection (no thermal units required), one normally open auxiliary contact, and a pilot light. Suitable for starting and stopping three-phase motors in industrial applications such as pumps, fans, and conveyors
EATON NEMA Size 3 non-reversing starter with electronic overload, rated 90 A, three-phase, three poles. Coil voltage 440/480V AC. Includes one normally open auxiliary contact and a pilot light signaling feature. Suitable for starting and stopping three-phase motors in applications such as pumps, fans, and conveyors
EATON
EATON NEMA Size 3 non-reversing starter with electronic overload, rated 90 A, three-phase, three poles. Coil voltage 440/480V AC. Includes one normally open auxiliary contact and a pilot light signaling feature. Suitable for starting and stopping three-phase motors in applications such as pumps, fans, and conveyors
Three-pole, non-reversing magnetic motor starter with electronic overload protection. NEMA Size 2, rated 45 A, 220/240V AC coil. Includes pilot light and one normally open auxiliary contact. For starting and stopping three-phase motors in industrial applications such as pumps, fans, and conveyors
EATON
Three-pole, non-reversing magnetic motor starter with electronic overload protection. NEMA Size 2, rated 45 A, 220/240V AC coil. Includes pilot light and one normally open auxiliary contact. For starting and stopping three-phase motors in industrial applications such as pumps, fans, and conveyors
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated 45 A at NEMA Size 2. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase AC motors in applications such as pumps, fans, and conveyors
EATON
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated 45 A at NEMA Size 2. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase AC motors in applications such as pumps, fans, and conveyors

More from EATON

View all EATON parts
Three-pole NEMA Size 1 non-reversing magnetic motor starter rated 27 A with electronic overload protection, eliminating the need for thermal units. Features a 24V AC coil, one normally open auxiliary contact, and a pilot light for signaling. Suitable for controlling three-phase motors in continuous-duty applications such as conveyors, pumps, and compressors
EATON
Three-pole NEMA Size 1 non-reversing magnetic motor starter rated 27 A with electronic overload protection, eliminating the need for thermal units. Features a 24V AC coil, one normally open auxiliary contact, and a pilot light for signaling. Suitable for controlling three-phase motors in continuous-duty applications such as conveyors, pumps, and compressors
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 1, 27 A, 120V AC Coil (MPN AN19DN0A5E045)
EATON
EATON NEMA Magnetic Motor Starter: Non-Reversing, 3 Poles, NEMA Size 1, 27 A, 120V AC Coil (MPN AN19DN0A5E045)
Non-reversing magnetic motor starter for three-phase motors. NEMA Size 1, rated 27 A, with 110/120V AC coil and electronic overload protection (no thermal units required). Includes one normally open auxiliary contact and a built-in pilot light for local status indication. Suitable for starting and protecting motors in industrial applications such as conveyors, pumps, and compressors
EATON
Non-reversing magnetic motor starter for three-phase motors. NEMA Size 1, rated 27 A, with 110/120V AC coil and electronic overload protection (no thermal units required). Includes one normally open auxiliary contact and a built-in pilot light for local status indication. Suitable for starting and protecting motors in industrial applications such as conveyors, pumps, and compressors
This EATON non-reversing starter with electronic overload is designed for three-phase motor control applications. Rated 9 A, NEMA Size 00, with a 440/480V AC coil and 3 poles. Includes a 1NO auxiliary contact and a pilot light for signaling. Electronic overload protection eliminates the need for thermal units
EATON
This EATON non-reversing starter with electronic overload is designed for three-phase motor control applications. Rated 9 A, NEMA Size 00, with a 440/480V AC coil and 3 poles. Includes a 1NO auxiliary contact and a pilot light for signaling. Electronic overload protection eliminates the need for thermal units
Non-reversing motor starter with electronic overload protection for three-phase motors. NEMA Size 1, rated 27 A, 3 poles, 24V AC coil. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping motors in industrial applications such as conveyors, pumps, and compressors
EATON
Non-reversing motor starter with electronic overload protection for three-phase motors. NEMA Size 1, rated 27 A, 3 poles, 24V AC coil. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping motors in industrial applications such as conveyors, pumps, and compressors
Three-phase non-reversing motor starter with electronic overload protection, rated 135 A at NEMA Size 4. Includes 110/120V AC coil, one normally open auxiliary contact, and a pilot light for status indication. Suitable for starting and stopping motors in industrial equipment such as conveyors, pumps, and compressors
EATON
Three-phase non-reversing motor starter with electronic overload protection, rated 135 A at NEMA Size 4. Includes 110/120V AC coil, one normally open auxiliary contact, and a pilot light for status indication. Suitable for starting and stopping motors in industrial equipment such as conveyors, pumps, and compressors
This EATON non-reversing starter is NEMA Size 1, rated 27 A, three-phase, three poles, with a 24V AC coil. It includes an integrated electronic overload protection, one normally open auxiliary contact, and a pilot light for signaling. No separate thermal units are required. Typical applications include controlling motors in conveyors, pumps, and other industrial machinery
EATON
This EATON non-reversing starter is NEMA Size 1, rated 27 A, three-phase, three poles, with a 24V AC coil. It includes an integrated electronic overload protection, one normally open auxiliary contact, and a pilot light for signaling. No separate thermal units are required. Typical applications include controlling motors in conveyors, pumps, and other industrial machinery
Non-reversing starter with electronic overload protection, rated 4 A and 600V AC. Features 3 poles, a selector switch, and a 45mm B Frame width. No thermal units required. Suitable for motor control applications such as conveyors, pumps, and fans
EATON
Non-reversing starter with electronic overload protection, rated 4 A and 600V AC. Features 3 poles, a selector switch, and a 45mm B Frame width. No thermal units required. Suitable for motor control applications such as conveyors, pumps, and fans