Send a part number, a photo, or a whole BOM — we supply it and stand behind it. Worldwide shipping to 80+ countries.

EATON AN19KN0T5E100 NEMA Size 3 Non-Reversing Starter with - Non-Reversing Starters with Electronic Overloads
EATONNon-Reversing Starters with Electronic Overloads

EATON AN19KN0T5E100 NEMA Size 3 Non-Reversing Starter with

The EATON NEMA Magnetic Motor Starter is a non-reversing starter with an electronic overload, designed for three-phase applications. This NEMA Size 3 unit is rated for 90 A and features a 24V AC coil, a 1NO auxiliary…

SKU 3G-OTH-44234

Brand
EATON
Item
AN19KN0T5E100 NEMA Size 3 Non-Reversing Starter with
Category
Non-Reversing Starters with Electronic Overloads
Available to Order
Trade pricing by quote — replies within 24h
Qty
WhatsApp an engineerMessage via Telegram
No account needed — your quote request goes straight to our engineers. A free account lets you track quotes and re-order faster.
Worldwide Shipping
Air & sea freight
Datasheet on Request
Technical specs
1-Day Quote
Replies within 24h

Local availability & support — Singapore

Local office
20 Woodlands Link #09-05, Singapore 738733
Phone
+65 8878 8355
Delivery
Same-day or next-business-day delivery within Singapore for in-stock items; 7–14 days for factory-order parts from Europe.
Payment
Invoicing in SGD. PayNow, bank transfer, and corporate PO accepted.
Ships to
Singapore

Technical Specifications

EATON
Manufacturer Part Number
AN19KN0T5E100
Type
NEMA Size 3, 90 A
Phase
Three
Poles
3
AC Coil
24V
Operator
None
Coil Voltage
24V AC
Operator Controls
None
Signaling Features
Pilot Light
Auxiliary Contact Form
1NO
Thermal Units Required
None (Not Applicable to Electronic Overloads)
Auxiliary Contacts Included
1NO

Technical Documents

No technical documents available for this product.
Request documentation
Not sure this is the right part? Get a recommendation.

Need installation or engineering help?

Installation, commissioning, maintenance plans, system design, and bundled product + service quotes — one team handles the full scope.
Talk to an engineer

Ask a question

EATON Products
3G Electric (S) Pte. Ltd. — Singapore

Product Description

The EATON NEMA Magnetic Motor Starter is a non-reversing starter with an electronic overload, designed for three-phase applications. This NEMA Size 3 unit is rated for 90 A and features a 24V AC coil, a 1NO auxiliary contact, and a pilot light for signaling. It requires no thermal units, as the electronic overload eliminates the need for them.

Frequently Asked Questions

What is the EATON NEMA Magnetic Motor Starter used for?

The EATON NEMA Magnetic Motor Starter is used to start and stop three-phase motors in industrial applications such as pumps, conveyors, and compressors. Its electronic overload protects the motor from damage without requiring thermal units. The pilot light provides visual status indication for operators.

What are the specifications of the EATON AN19KN0T5E100 motor starter?

The EATON AN19KN0T5E100 is a NEMA Size 3, non-reversing magnetic motor starter rated for 90 A. It has a 24V AC coil, three-phase operation, one normally open auxiliary contact, and a built-in pilot light. The electronic overload eliminates the need for separate thermal units.

Where to buy the EATON AN19KN0T5E100 worldwide?

3G Electric supplies the EATON AN19KN0T5E100 magnetic motor starter worldwide. As a global industrial equipment distributor since 1990, we handle full logistics, customs clearance, and delivery to your site. Contact us for availability and lead time.

How to install the EATON NEMA Size 3 motor starter?

Mount the starter on a flat surface using the provided holes. Connect three-phase power to the line terminals and the motor to the load terminals. Wire the 24V AC coil to a control circuit. Set the electronic overload dial to the motor's full-load amperage. Always follow local electrical codes.

Used in

Common applications for EATON
Industrial control panels — Eaton M22 flush push buttons for momentary machine start/stop commands
Motor control centers — Eaton NEMA reversing starters with electronic overloads for conveyor belt direction control
HVAC systems — Eaton definite purpose starters with thermal overloads for compressor and fan motor protection
Process automation — Eaton SL7 tower lights with IP66 bases for visual status indication in wet environments
Machine tool signaling — Eaton 10250T LED pilot lights with push-to-test for operator panel status lamps
Access control — Eaton M22 keyed selector switches for equipment mode selection in secured areas

EATON Products

3G Electric supplies EATON non-reversing starters with electronic overloads. We supply genuine products with in-stock availability on common SKUs, technical documentation, commissioning support, and warranty service — worldwide.

You might also need

Burners & Combustion Pumps & Compressors Spare Parts All Products

Compatible alternatives & equivalents

Cross-referenced by specification & description
Three-pole NEMA Size 2 non-reversing motor starter rated 45 A with integrated electronic overload protection. Operates on 24V AC coil voltage and includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase motors in applications such as pumps, conveyors, and compressors
EATON
Three-pole NEMA Size 2 non-reversing motor starter rated 45 A with integrated electronic overload protection. Operates on 24V AC coil voltage and includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase motors in applications such as pumps, conveyors, and compressors
Three-phase non-reversing motor starter with electronic overload protection, rated 90 A, NEMA Size 3, 3 poles, and 220/240V AC coil. Includes one normally open auxiliary contact and a pilot light for signaling. Suitable for starting and stopping AC motors in industrial applications such as conveyors, pumps, fans, and compressors
EATON
Three-phase non-reversing motor starter with electronic overload protection, rated 90 A, NEMA Size 3, 3 poles, and 220/240V AC coil. Includes one normally open auxiliary contact and a pilot light for signaling. Suitable for starting and stopping AC motors in industrial applications such as conveyors, pumps, fans, and compressors
Non-reversing magnetic motor starter for three-phase motors. NEMA Size 2, 45 A rating, 24V AC coil, 3 poles. Includes electronic overload protection (no thermal units required), one normally open auxiliary contact, and a pilot light for status indication. Suitable for starting and stopping motors in industrial applications such as conveyors, pumps, and compressors
EATON
Non-reversing magnetic motor starter for three-phase motors. NEMA Size 2, 45 A rating, 24V AC coil, 3 poles. Includes electronic overload protection (no thermal units required), one normally open auxiliary contact, and a pilot light for status indication. Suitable for starting and stopping motors in industrial applications such as conveyors, pumps, and compressors
Three-pole NEMA Size 2 non-reversing motor starter rated 45 A, with 24V AC coil and electronic overload protection. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase motors in industrial applications such as conveyors, pumps, and compressors
EATON
Three-pole NEMA Size 2 non-reversing motor starter rated 45 A, with 24V AC coil and electronic overload protection. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping three-phase motors in industrial applications such as conveyors, pumps, and compressors
Non-reversing motor starter with electronic overload protection for three-phase motors. NEMA Size 1, rated 27 A, 3 poles, 24V AC coil. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping motors in industrial applications such as conveyors, pumps, and compressors
EATON
Non-reversing motor starter with electronic overload protection for three-phase motors. NEMA Size 1, rated 27 A, 3 poles, 24V AC coil. Includes one normally open auxiliary contact and a pilot light for status indication. Suitable for starting and stopping motors in industrial applications such as conveyors, pumps, and compressors
This EATON non-reversing starter is NEMA Size 1, rated 27 A, three-phase, three poles, with a 24V AC coil. It includes an integrated electronic overload protection, one normally open auxiliary contact, and a pilot light for signaling. No separate thermal units are required. Typical applications include controlling motors in conveyors, pumps, and other industrial machinery
EATON
This EATON non-reversing starter is NEMA Size 1, rated 27 A, three-phase, three poles, with a 24V AC coil. It includes an integrated electronic overload protection, one normally open auxiliary contact, and a pilot light for signaling. No separate thermal units are required. Typical applications include controlling motors in conveyors, pumps, and other industrial machinery

More from EATON

View all EATON parts
This NEMA Size 1 non-reversing starter is rated for 27 A and 110/120V AC coil voltage, suitable for three-phase motor control. It includes an electronic overload relay (no thermal units required), one normally open auxiliary contact, and a pilot light for signaling. Typical applications include conveyors, pumps, and compressors in industrial environments
EATON
This NEMA Size 1 non-reversing starter is rated for 27 A and 110/120V AC coil voltage, suitable for three-phase motor control. It includes an electronic overload relay (no thermal units required), one normally open auxiliary contact, and a pilot light for signaling. Typical applications include conveyors, pumps, and compressors in industrial environments
Non-reversing magnetic motor starter for three-phase motors, NEMA Size 0 rated 18 A. Features a 24V AC coil, three poles, integrated electronic overload protection (no thermal units required), one normally open auxiliary contact, and a pilot light for signaling. Suitable for starting and stopping motors in applications such as pumps, conveyors, and compressors
EATON
Non-reversing magnetic motor starter for three-phase motors, NEMA Size 0 rated 18 A. Features a 24V AC coil, three poles, integrated electronic overload protection (no thermal units required), one normally open auxiliary contact, and a pilot light for signaling. Suitable for starting and stopping motors in applications such as pumps, conveyors, and compressors
This EATON non-reversing motor starter is a NEMA Size 4 unit rated at 135 A for three-phase applications. It features a 24V AC coil, three poles, one normally open auxiliary contact, and an integrated pilot light for status indication. Electronic overload protection is included, eliminating the need for separate thermal units. Typical uses include starting and stopping motors in industrial machinery, pumps, and conveyors
EATON
This EATON non-reversing motor starter is a NEMA Size 4 unit rated at 135 A for three-phase applications. It features a 24V AC coil, three poles, one normally open auxiliary contact, and an integrated pilot light for status indication. Electronic overload protection is included, eliminating the need for separate thermal units. Typical uses include starting and stopping motors in industrial machinery, pumps, and conveyors
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated NEMA Size 0 at 18 A. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light. Suitable for starting and protecting three-phase motors in industrial control panels
EATON
Three-pole non-reversing magnetic motor starter with electronic overload protection, rated NEMA Size 0 at 18 A. Coil voltage 220/240V AC. Includes one normally open auxiliary contact and a pilot light. Suitable for starting and protecting three-phase motors in industrial control panels
Non-reversing motor starter for three-phase motors up to 45 A. Includes electronic overload protection and a pilot light for status indication. Features a 440/480V AC coil and one normally open auxiliary contact. Suitable for industrial applications such as conveyors, pumps, and compressors
EATON
Non-reversing motor starter for three-phase motors up to 45 A. Includes electronic overload protection and a pilot light for status indication. Features a 440/480V AC coil and one normally open auxiliary contact. Suitable for industrial applications such as conveyors, pumps, and compressors
Three-pole NEMA Size 0 non-reversing motor starter rated 18 A with 24V AC coil. Integrated electronic overload protection eliminates thermal units. Includes one normally open auxiliary contact and pilot light for status indication. Suitable for starting and stopping three-phase motors in industrial applications such as conveyors, pumps, and compressors
EATON
Three-pole NEMA Size 0 non-reversing motor starter rated 18 A with 24V AC coil. Integrated electronic overload protection eliminates thermal units. Includes one normally open auxiliary contact and pilot light for status indication. Suitable for starting and stopping three-phase motors in industrial applications such as conveyors, pumps, and compressors
Three-pole non-reversing motor starter with electronic overload protection, rated 27 A at NEMA Size 1. Coil voltage 220/240V AC. Includes pilot light and one normally open auxiliary contact. Suitable for starting and stopping three-phase AC motors in fixed-direction applications such as conveyors, pumps, and fans
EATON
Three-pole non-reversing motor starter with electronic overload protection, rated 27 A at NEMA Size 1. Coil voltage 220/240V AC. Includes pilot light and one normally open auxiliary contact. Suitable for starting and stopping three-phase AC motors in fixed-direction applications such as conveyors, pumps, and fans
Non-reversing magnetic motor starter for three-phase motors, NEMA Size 0 rated 18 A. Features integrated electronic overload protection, 208V AC coil, 3 poles, one normally open auxiliary contact, and a pilot light for local status indication. Suitable for controlling conveyors, pumps, and compressors in industrial applications
EATON
Non-reversing magnetic motor starter for three-phase motors, NEMA Size 0 rated 18 A. Features integrated electronic overload protection, 208V AC coil, 3 poles, one normally open auxiliary contact, and a pilot light for local status indication. Suitable for controlling conveyors, pumps, and compressors in industrial applications